Elkay EZOSTL8S3JOCSA User Manual

Versatile Bi-Level Wall Mount Water Cooler
Hands Free® Sensor & Pushbar Activated
PRODUCT SPECIFICATION
Self-contained, wall mount sensor-activated electric two-level water cooler. Model EZOSTL8 shall deliver 8 GPH of 50°F drinking water at 90°F ambient and 80°F inlet water. Right-hand unit shall have electronic sensor-operated Hands-Free® operation. Left-hand unit shall have self-closing Easy-Touch Controls on front, left and right. Unit shall meet ADA guidelines. Unit shall be
lead-free design which is certied to NSF/ANSI 61 and 372 and meets Federal
and State low-lead requirements.
STANDARD FEATURES
Electronic sensor-operated Hands-Free® operation on right-hand unit
Easy-Touch front and side pushbar controls on left-hand unit
*Versatile design allows units to be installed either left-hand high and
right-hand low or left-low and right high
Cooler Panel Finish: Stainless Steel wrapper
Rated for Indoor Use
COOLING SYSTEM
Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
Cooling Unit: Tube type. Self-cleansing. Continuous Copper tubing which is fully insulated with EPS foam that meets UL requirements for self-extinguishing material.
Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube.
Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment,
whichever date falls rst.
Model EZOSTL8S3JOCSA
RATED FOR INDOOR USE ONLY
ONLY AVAILABLE FOR SAUDI ARABIA
*Versatile cooler conguration
as shipped
*Versatile cooler conguration
alternate installation
CONSTRUCTION
Electronic Hands-Free® operation: On-off solenoid valve is actuated by an infrared light beam sensor. When light beam is interrupted by user in front of cooler, the sensor actuates to begin water dispensing. A built-in time delay is provided to prevent
actuation by passerby trafc.
• Fountain Top: One piece stainless steel top, polished to a uniform Elkay satin luster nish
• Frame: Galvanized steel chassis support
• Exclusive Flexi-Guard® Safety bubbler: Innovative design utilizes
an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact.
• Upper Shroud: Contoured shock-absorbing provides additional protection against accidental injury. No exposed fasteners.
• Removable Wrapper: One-piece design offers easy accessibility
to interior.
Cooler cabinet available as Stainless Steel
CAPACITIES CHART
Model Voltage / Hertz
EZOSTL8S3JOCSA 220V / 60Hz 8 GPH 2.0 370 72 lbs
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
Chilling**
Capacity
F.L.
Amps
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Rated Watts
Approx.
Ship
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.
Wt.
Tested by:
SASO 1062
ADA
COMPLIANT
(SASO/IEC 60335-1) &
SASO/IEC
60335-2-89
Compliant
++
SPEC00323 (02/2015)
NSF/ANSI
61 and 372
Certied
© 2015 Elkay
Versatile Bi-Level Wall Mount Water Cooler Hands Free® Sensor & Pushbar Activated Model EZOSTL8S3JOCSA
IMPORTANT! INSTALLER PLEASE NOTE:
These units are designed and built to provide water to the user which has not been altered by materials in the cooler waterway. The grounding of electrical equipment such as telephone, computers, etc. to water lines is a common procedure. This grounding may be in the building but may also occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which results in a metallic taste or an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown.
ROUGH-IN FOR LEFT-HAND HIGH SIDE MODELS
18 3/8"
2"
51mm
34 5/16" 872mm
9/32" 7mm
(ALT. LOCATION)
24 1/2"
622mm
22 15/16"
583mm
DIA. ((12)
A
E
F
19 7/16" 494mm
D
PREFFERED
LOCATION
6 3/8"
162mm
467mm
17 7/16"
443mm
6 3/8"
162mm
2"
51mm
7/8"
22mm
13 15/16" 354mm
18 3/8"
467mm
6 3/8"
162mm
B
F
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
FINISHED FLOOR
6 3/8"
162mm
PREFFERED
LOCATION
2"
51mm
7"
178mm
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
ONLY AVAILABLE FOR SAUDI ARABIA
NOTICE
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap which is provided by the installer should also be plastic to completely isolate the cooler from the building plumbing system.
19"
483mm
HANGER BRACKET
2"
51mm
38 3/8"
975mm
ORIFICE
A
19"
483mm
E
21 7/8"
556mm
28 13/16"
732mm
HEIGHT
36 13/16"
936mm
RIM
HEIGHT
32 7/8"
835mm
ORIFICE HEIGHT
31 5/16" 796mm
RIM
HEIGHT
REQUIREMENT
27"
686mm
ADA
12 1/2"
318mm
C
1 7/16" 37mm
3"
76mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/2” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/2” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
Page 2
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes:
Printed in U.S.A.
© 2014 Elkay