Hands-Free® Sensor-Activated
Wall Mount Water Cooler
SPECIFICATIONS
PRODUCT SPECIFICATION
Self-contained, wall mount sensor-activated electric water cooler.
Refrigerated EZO8 models offer a chilling capacity of
8 gallons per hour of 50°F drinking water, based upon 80°F
inlet water and 90°F ambient. Models EZOD are
non-refrigerated and shall deliver non-chilled drinking water.
Unit shall meet ADA guidelines. Unit shall be lead-free
design which is certied to NSF/ANSI 61 and 372 and meets
Federal and State low-lead requirements. Unit shall be certied
to UL399 and CAN/CSA 22.2 No. 120.
Models EZOD are non-refrigerated. Requires outlet for power cord.
STANDARD FEATURES
• Hands-Free® sensor operation with 30-second auto shut-off and
adjustable sensor range
• Extra deep basin minimizes splashing; with integral drain
• Available with Flexi-Guard® Safety bubbler or Vandal-resistantt
bubbler. Vandal-resistantt bubbler (tincludes “VR” code in model no.)
• Valve with built-in ow regulator to provide constant stream from 20
to 105 psi water pressure
• Finish options: Impact-resistant vinyl coating or stainless steel
wrapper
• Rated for Indoor use
COOLING SYSTEM (Models EZO(VR)8 only)
• Compressor: Hermetically-sealed, reciprocating type, single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan
motor is permanently lubricated.
• Cooling Unit: Tube type. Self-cleansing. Continuous copper tubing
which is fully insulated with EPS foam that meets UL requirements
for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately
calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable
thermostat is factory preset. Requires no adjustment other than for
altitude requirements.
Models EZO8 and EZOD
RATED FOR INDOOR USE ONLY
CONSTRUCTION
• Electronic Hands-Free® operation: On-off solenoid valve is
actuated by an infrared light beam sensor. When light beam
is interrupted by user in front of cooler, the sensor actuates to
begin water dispensing. A built-in time delay is provided to
prevent actuation by passerby trafc.
• Fountain Top: One piece stainless steel top, polished to a
uniform Elkay satin luster nish
• Frame: Galvanized steel chassis support
• Exclusive Flexi-Guard® Safety bubbler: Innovative design
utilizes an infused anti-microbial pliable polyester elastomer to
prevent accidental mouth injuries. Flexes on impact.
• Upper Shroud: Contoured shock-absorbing provides
additional protection against accidental injury. No exposed
fasteners.
• Removable Wrapper: One-piece design offers easy
accessibility to interior.
• Cooler cabinet available as Light Gray Granite Vinyl Clad
Steel or Stainless Steel (additional cost) construction
Warranty: 5 year limited warranty on the unit’s refrigeration
system. Electrical components and water system are
warranted for 12 months from date of installation or 18
months from factory shipment, whichever date falls rst.
CAPACITIES CHART
Model
EZO(VR)8* 115V / 60Hz 8 GPH 4.00 370 51 lbs
EZO8*2JO 220V / 50Hz 6.7 GPH 2.00 370 51 lbs
EZO8*3JO 220V / 60Hz 8 GPH 2.00 370 51 lbs
EZOD* 115V / 60Hz
*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler wrapper.
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice.
Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
– – –
2222 Camden Court
Oak Brook, IL 60523
Rated
Watts
630-572-3192
elkay.com
Approx.
Ship
Wt.
25 lbs
This specication describes an Elkay product with design, quality and functional
benets to the user. When making a comparison of other producer’s offerings,
be certain these features are not overlooked.
UL399 and
CAN/CSA 22.2
No. 120
Certied
ADA
COMPLIANT
• • •
++ • •
++ • •
• • •
ANSI/NSF
61 and 372
Certied
© 2014 Elkay
SPEC12-26 (04/2014)
Hands-Free
Open space rough-in design permits new installation or replacement of existing
creating an electrolysis which creates a metallic taste or causes an increase in the
®
Sensor-Activated
Wall Mount Water Cooler
Models EZO8 AND EZOD
fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has
not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water
lines is a common procedure. This grounding may be in the building or occur away
from the building. This grounding can cause electrical feedback into a water cooler
metal content of the water. This condition is avoidable by installing the cooler using
the proper materials as shown below.
18 3/8"
467mm
9/32"
7mm
6 3/8"
(6)
O
162mm
B
E
‰
6 3/8"
162mm
2"
51mm
E
A
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap, which is provided by the installer, should also be plastic to completely
isolate the cooler from the building plumbing system.
32 7/8"
835mm
ORIFICE
HEIGHT
NOTICE
8 1/16"
205mm
19"
484mm
HANGER BRACKET
21 7/8"
556mm
19"
483mm
17 7/16"
443mm
F
7"
178mm
2"
51mm
3 7/8"
98mm
5 3/4"
146mm
7"
178mm
13 15/16"
354mm
FINISHED FLOOR
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
D
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
28 13/16"
732mm
31 5/16"
796mm
RIM
HEIGHT
27"
686mm
ADA
REQUIREMENT
C
12 1/2"
318mm
5 7/8"
150mm
77mm
3"
2"
51mm
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2014 Elkay