Water Coolers – Barrier-Free Access (Adult & Child)
S PECI F I C AT I O N S
GENERAL
Self-contained, wall hung electric refrigerated water cooler.
Chilling capacity of 50°F drinking water, based upon 80°F inlet
water and 90°F ambient.
Models EZO4 and EZO8 sensor-operated coolers have unique
Hands-Free
vide constant stream from 20 to 105 psi water pressure.
Non-pressurized stainless steel cooling tank is standard. Nonpressurized water tank is located after bubbler valve, so that tank
is subject to line pressure only when sensor is activated.
ADA COMPLIANT
hese Water Coolers comply with the requirements of A.D.A.
T
Americans with Disabilities Act) when properly installed. Also
(
eets the guidelines for children’s environments providing the
m
loor to orifice height is 30" or less and proper clear floor space
f
s provided for parallel approach. (Based on Architectural and
i
ransportation Barriers Compliance Board final ruling.) Check
T
Local and State Codes.
NO LEAD DESIGN
These Water Coolers are certified to be lead-free as defined by
the Safe Drinking Water Act. Elkay Water Coolers are manufactured with a waterway system utilizing copper components
and completely lead-free materials. These waterways have no
lead because all lead materials, such as leaded brass, have been
removed. All joints are brazed using silver solder only. No lead
solder is permitted. A strainer with an easily cleanable screen is
provided to allow trapping and convenient removal of waterborne
particulate of 140 microns and larger prior to their entry into the
water cooler.
CAPACITIES CHART
Model Base
Number Rate 70°F 80°F 90°F Watts Amps Option Lbs.
EZ O4 4.0 5.0 4.4 4.0 370 4.0 No 56
EZ O8 8.0 9.7 8.8 8.0 370 4.0 No 56
**Based on 80°F inlet water temperature.
Rated watts shown are based on operational (run) time, in compliance with A.R.I.
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people
served per hour (usage), ambient temperatures, and inlet water temperature.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
115V, 60 Hz single phase. Sealed-in lifetime oil supply. Equipped
with electric cord and three prong molded rubber plug (domestic
models).
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Self cleansing. Tube
portion is continuous coil of copper tubing. Tank is stainless
steel. Fully insulated with EPS foam which meets Underwriters
Laboratories Inc. requirements for self-extinguishing material.
Refrigerant Control: Refrigerant HFC-134a is controlled by
accurately calibrated capillary tube for positively trouble-free
operation.
Temperature Control: Enclosed adjustable thermostat is factory pre-set. Requires no adjustment other than for altitude
requirements. Easily accessible.
®
operation. Valve with built-in flow regulator to pro-
**GPH of 50°F Drinking Water
Room Temperature °F
Full Glass Ship.
Rated Load Filler Wt.
Wall Mount Sensor-Operated Hands-Free
NSF/ANSI 61 Compliant
Models EZO4 and EZO8
Model EZO8
RATED FOR INDOOR APPLICATIONS ONLY
CONSTRUCTION
Electronic Sensor Hands-Free®Operation: On-off solenoid valve
is actuated by an infrared light beam sensor. When light beam is
interrupted by subject in front of cooler desiring a drink, the sensor
actuates the solenoid valve which then opens to allow water flow.
No physical contact with cooler is required. A built in time delay is
provided to prevent actuation by persons moving past cooler. There
is a maximum running time of 30 seconds to prevent malicious damage to the cooler or water damage if sensor vision is blocked. Unit
automatically resets when blockage is removed. Sensor range is
adjustable.
Frame: Galvanized structural steel chassis supports refrigeration
system and fastens to wall. Provides increased structural integrity
and rigidity to cooler.
Stainless Steel Basin: One piece polished to a uniform Elkay
bright luster finish. Basin has integral drain grid, embossed
bubbler pad. No exposed fasteners.
Exclusive Flexi-Guard
utilizes an infused anti-microbial pliable polyester elastomer to
prevent accidental mouth injuries. Flexes on impact, then returns
to original position. Strong. Abrasion-resistant. Anti-sweat.
Keyed in loca tion to prevent rotation.
Upper Shroud: Contoured shock-absorbing, provides additional
protection against accidental injury. No exposed fasteners.
Lower Shroud: One piece easy to remove and replace. Allows
access to internal components from three sides.
Cabinet: Cabinet design allows for flush to wall mounting. No
recess space is required.
Color Selection: Unless otherwise specified cabinet is two-tone
gray on upper shroud with textured gray lower shroud. Stainless
Steel lower shroud available at extra cost.
Protected by Elkay’s 5 Year Limited Warranty on the refrigeration system of the unit.
Elkay Pressure-Type Water Coolers are designed to operate on
20 psi to 105 psi supply line pressure. If inlet pressure is above
105 psi, a pressure regulator must be installed in the supply line.
Any damage caused by reason of connecting this product to supply line pressures lower than 20 psi or higher than 105 psi is not
covered by the warranty.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
®
Safety Bubbler: Innovative design
®
In keeping with our policy of continuing product improvement, Elkay reserves the right to change
product specifications without notice. Please visit elkayusa.com for most current version of Elkay
product specification sheets.
Elkay
elkayusa.com
2222 Camden Court
Oak Brook, IL 60523
These units comply with A.R.I. Standard 1010.
This cooler is certified by WQA to lead-free compliance including
NSF/ANSI 61-ANNEX G, AB 1953.
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers’ offerings, be certain these features are not
overlooked.
Printed in U.S.A.
©2011 Elkay
(Rev. 4/11) 12-26D
Wall Mount Sensor-Operated Hands-Free
N
OTE: WATERFLOW
D
IRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE
CONNECT
COLD WATER
SUPPLY
1
/4" O.D. TUBE
W
ATER INLET
T
O COOLER
B
UILDING WATER
I
NLET
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
P
USHING TUBE IN BEFORE
P
ULLING IT OUT HELPS TO
R
ELEASE TUBE
AB
C
18-3/8"
(467mm)
6-3/8"
(162mm)
9/32" (7mm) Ø
HOLES(6)
B
E
D
F
A
E
C
L
6-3/8"
(162mm)
*21-7/8"
(556mm)
*19"
(483mm)
*17-7/16"
(443mm)
*13-15/16"
(354mm)
7"
(178mm)
7"
(178mm)
5-3/4"
(146mm)
3-7/8"
(98mm)
2"
(51mm)
2"
(51mm)
*32-7/8"
(835mm)
ORIFICE
HEIGHT
*27"
(686mm)
ADA
REQUIREMENT
*31-5/16"
(796mm)
RIM HEIGHT
*28-13/16"
(732mm)
8-1/16"
(205mm)
19"
(483mm)
HANGER BRACKET
2"
(51mm)
C
3"
(76mm)
5-7/8"
(150mm)
*12-1/2"
(318mm)
LEGEND
A = RECOMMENDED WATER SUPPLY LOCATION. SHUT-OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8 O.D. UNPLATED COPPER TUBE.
3” (76mm) MAXIMUM OUT FROM WALL.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4" O.D. DRAIN STUB 2 IN. (51mm) OUT FROM WALL.
C = 1-1/4" TRAP NOT FURNISHED.
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX.
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL.
*REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER.
FRONT VIEW SIDE VIEW
®
Water Coolers – Barrier-Free Access (Adult & Child)
NSF/ANSI 61 Compliant
Models EZO4 and EZO8
Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
When the cooler is mounted as shown the location available is from 15" to 21-11/16"
from floor and 1-1/16" to 7-1/4" from the left of centerline. Space is also available
from 21-11/16" to 24-5/8" from floor and 2-3/4" to 7-1/4" from the left of centerline.
Additional space is also available from 24-5/8" to 26-11/16" from floor and 3-3/4" to
7-1/4" from the left of centerline. Connections approaching the limits of these areas
may be restricted and should only be considered for use until after an examination of
the cooler has been made.
his water cooler has been designed and built to provide water to the user which has
T
ot been altered by materials in the cooler waterways.
n
he grounding of electrical equipment such as telephone, computers, etc., to water
T
ines is a common procedure. This grounding may be in the building but may also
l
ccur away from the building. This grounding can cause electrical feedback into a
o
ater cooler creating an electrolysis which creates a metallic taste or causes an
w
ncrease in the metal content of the water. This condition is avoidable by installing the
i
ooler using the proper materials as shown below.
c
This water cooler must be connected to the water supply using a dielectric coupling.
The cooler is furnished with a non-metallic strainer which meets this requirement.
The drain trap which is provided by the installer should also be plastic to completely
solate the cooler from the building plumbing system.
i
RATED FOR INDOOR APPLICATIONS ONLY
ROUGH-IN DIMENSIONS
IMPORTANT!
NSTALLER PLEASE NOTE:
I
NOTICE
Elkay
12-26D (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.