Elkay ERC8-1B Installation Manual

ERC8-1B/2B, TRC8-1B/2B
Installation Instructions
ERC8-1B/2B, TRC8-1B/2B
Refrigeration Packages
1/4" (6 mm) O.D. TUBE OUTLET
1/4" (6 mm) O.D. TUBE INLET
TEMPERATURE ADJUSTMENT
ELECTRICAL
NOTE: It is important to insure proper ventilation. Allow a minimum clearance of 6 inches (152 mm) in front and 3 inches (76mm) in the rear of the unit. If unit is to be installed in an enclosure, allow the following clearances around unit - 1 inch (25mm) each side, 3 inches (76mm) in the rear, 3 inches (76mm) inches above wall.
This chiller has been designed for use with potable water and includes an o-ring seal on the drain plug. This fitting should be replaced if the unit is to be used with more aggressive fluids.
3/8" (9 mm) O.D. TANK DRAIN
ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
96602C (Rev. D)
ITEM
NO.
1 2 3 4 5 6 7 8 9
10
11 12 13
14*
15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
NS NS
ITEMIZED PARTS LIST
PART NO.
23027C 31513C 31513C
191550951550
31475C 20282C 70018C 70091C 70009C 66305C 50189C 66202C 66267C 35807C 35801C 35795C 30180C 30181C 30182C 50076C
100806740570
19037000
101516143550
66455C 23025C 70772C 23033C 23034C 23036C 23037C 23031C 23026C 23028C
DESCRIPTION
Cover - Electrical Control - Cold Control - freeze prot. Fan Motor Fan Blade Fan Bracket Fan Nut Washer - Fan Blade Screw - Motor Mounting Condenser Shroud Drier Heat Exchanger Compressor serv Pak (115v) Relay Overload Overload Spring Terminal Cover Bale Strap Sound Dampner Grommet Clip - Compressor Mtg. Stud - Compressor Mtg. Evaporator Assy Panel - Front Drain Plug Panel - Side Right Hand Panel - Side left Hand Air Deflector Electrical Compartment Bracket - Evap. Locating Panel - Rear Cover - Top
ERC8-1B/2B, TRC8-1B/2B
FREEZE PROTECT THERMOSTAT
COLD CONTROL THERMOSTAT
WIRING DIAGRAM
ERC8-2B, TRC8-2B - 220/240V, 50 HZ
ITEM
PART NO.
NO.
191555551550
4
66476C
13
35809C
14*
35802C
15
35796C
16
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY. NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
DESCRIPTION
Fan Motor Heat Exchanger Compressor Serv Pak Relay Overload
INSTALLATION
1. It is important to insure proper ventilation. For remote installation a minimum clearance of 6 inches (152 mm) to the front must be maintained, 1 inch (25 mm) each side, 3 inches (76 mm) to the rear above the unit. Wall grille EG-1 or EG-2 to be ysed when unit is inserted into an enclosure. Install unit as close as possible to wall grille a 6 inch (152 mm) clearance beyond the front of the wall grille is required for adequate air circulation.
2. Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply connections as required.
3. Connecting lines to be of copper, thoroughly flushed to remove all foreign matter before being connected to cooler. If flushing does not remove all particles, a water strainer should be installed in supply line
4. Connect cooler to building supply line with a shut-off valve and install a union connection between the valve and cooler
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
START-UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 50°F (+/- 5°) under normal conditions. For colder water, adjust screw on item no. 3 CW. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload prctector. Lubrication: Motors are lifetime lubricated.
24
28
30
29
31
25
3
2
1
4 TO 9
10,11
12
13
14
15 TO 19
27
20
26
21 TO 23
96602C (Rev. D)
ELKAY MANUFACTURING COMPANY - 2222 CAMDEN COURT - OAK BROOK, IL 60523 - 630.574.8484
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
Loading...