PRODUCT SPECIFICATION
Remote type, electric refrigerated water chiller unit. Chilling
capacity of 19 gallons per hour of 50°F drinking water, based on
80°F inlet water and 90°F ambient. Installs directly under fountain
or other application, or may be located in a service area to serve a
remote outlet (within 15 feet recommended). Unit shall be
lead-free design which is certied to NSF/ANSI 61 and 372 and
meets Federal and State low-lead requirements. Unit shall be
certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Easily converts any Drinking Fountain into a Water Cooler
• Provides chilled drinking water
• Designed to service up to two stations
• Installs within or behind building walls, out of the way
COOLING SYSTEM
• Compressor: Hermetically-sealed, reciprocating type 1/2 HP,
single phase. Sealed-in lifetime lubrication.
• Power
Model
ER191 115V - 60Hz 1 19.2 750
ER192 220/240V - 50/60Hz 1 14.6 750
ER193 220V - 60Hz 1 14.6 750
Voltage -
Hertz
Compressor
Phase
F.L.
Amps
Rated
Watts
Remote Chiller 19 GPH
Air Cooled
Models ER191, ER192 and ER193
RATED FOR INDOOR USE ONLY
• Condenser: Fan cooled. Fan motor is permanently lubricated.
• Cooling Unit: Combination tube-tank type. Continuous copper
tubing with stainless steel tank. Fully insulated with EPS foam
that meets UL requirements for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by
accurately calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable
thermostat is factory preset. Requires no adjustment other than
for altitude requirements.
CAPACITIES CHART
Inlet
Model
ER191 80° 19.0 GPH 115 lbs • •
ER192 80° 19.0 GPH 115 lbs ++ •
ER193 80° 19.0 GPH 115 lbs ++ •
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
++Complies; not third party certied.
Water
Temp
(°F)
Chilling**
Capacity
Approx.
Ship
Wt.
CONSTRUCTION
• Cabinet: Rust-resistant galvanized steel
Warranty: 5 year limited warranty on the unit’s
refrigeration system. Electrical components and
water system are warranted for 12 months from date
of installation or 18 months from factory shipment,
whichever date falls rst.
UL399 and
CAN/CSA 22.2
No. 120
Certied
NSF/ANSI
61 and 372
Certied
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice.
Please visit elkay.com for the most current version.
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
SPEC13-07 (08/2015)
© 2015 Elkay
Remote Chiller 19 GPH
Air Cooled
Models ER191, ER192 and ER193
NOTE: It is important to insure proper ventilation. Allow a minimum
clearance of 12 inches (305mm) in front and 3 inches (76mm) in the rear
of the unit. If unit is to be installed in an enclosure, allow the following
clearances around unit - 1 inch (25mm) each side, 3 inches (76mm) in the
rear, 3 inches (76mm) above wall.
TOP VIEW
8 1/8 "
205mm
4 1/4 "
114mm
10 1/4 "
260mm
5 1/8 "
130mm
1 9/16 "
40mm
A
TEMPERATURE
ADJUSTMENT
23 "
584mm
B
4 7/8 "
123mm
ROUGH-IN DIMENSIONS
RATED FOR INDOOR USE ONLY
Drain Plug: This chiller is provided with a plastic drain plug which
incorporates an o-ring seal. This tting is designed for potable
water applications and should be replaced with a suitable tting
if chiller is used with more aggressive liquids.
ELECTRICAL
1 3/4 "
44mm
ALTERNATE
ELECTRICAL
LOCATION
LEGEND
A = 3/8” O.D. TUBE WATER OUT
B = 3/8” O.D. TUBE WATER INLET
C = 3/8” O.D. TUBE TANK DRAIN
1 1/4 "
32mm
25 3/4 "
654mm
C
FRONT VIEW SIDE VIEW
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2015 Elkay