No Lead Remote Chiller
Air Cooled
Model ER-10
SPECIFICATIONS
GENERAL
Remote type, electric refrigerated, water chiller unit. Chilling
capacity of 9.6 gallons per hour of 50°F drinking water, based
upon 80°F inlet water and 90°F ambient.
Compact, highly efficient water chiller units are designed for use
with any drinking fountain. Also connects to a bubbler, glass filler
or cold water dispenser. Converts a fountain into a water cooler.
Installs directly under fountain or other application, or may be
located in a service area to serve up to two remote outlets (within
15 feet of chiller recommended). Also recommended for photoprocessing, medical or experimental laboratories and a pre-cooler
for beverage dispensing.
NO LEAD DESIGN
THIS WATER CHILLER COMPLIES WITH THE LEAD-FREE
DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986
AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Water Chillers are manufactured with a waterway system
utilizing copper components and completely lead-free materials.
These waterways hav
materials, such as leaded brass, have been removed. All joints are
brazed using silver solder only. No lead solder is permitted.
e no lead because all lead-containing
®
ER-10 Remote Chiller
CAPACITIES CHART
*GPH of 50°F Drinking Water
Inlet
Water
Model
Temp.
Number
ER-10 80° 11.1 10.4 9.6 8.8 115 67.2 48 73
*Based on 80° Inlet Water Temperature.
Rated watts shown are based on operational (run) time, in accordance with ARI
Standard 1010 conditions. Specific applications will determine the actual watts
consumed per hour. Watts consumed will be based on number of people served
per hour (usage), ambient temperatures, and inlet water temperature.
Multiple-outlet capacities. Up to 2 stations.
(°F)
70° 15.0 13.8 12.7 11.5
{
90° 8.4 7.7 7.3 6.5
Room Temp. ° F
70° 80° 90° 100°
No. People Served
50°F Drinking Water
School
& Office
Light
Mfg.
Heavy
Mfg.
Ship.
Wt.
Lbs.
COOLING SYSTEM
Motor Compressor: Hermetically sealed, reciprocating type,
1/4 HP, 115VAC, 60Hz single phase. Sealed in lifetime oil supply.
Power: Rated 5.8 amps; 490 Watts.
Condenser: Fan cooled, copper tube with aluminum fins. Fan
motor is permanently lubricated.
Cooling Unit: Combination tube-tank type. Tube portion is continuous coil of copper tubing. Tank is copper.
Refrigerant Control: Refrigerant HFC134a is controlled by accurately calibrated capillary tube for positively trouble-free operation.
Temperature Control: Enclosed adjus
table thermostat is factory
preset. Requires no adjustment other than for altitude
requirements.
CONSTRUCTION
Cabinet: Rust-resistant, galvanized steel. Expanded, cold rolled
steel grill is painted black.
Drain Plug: This chiller is provided with a plastic drain plug which
incorporates an o-ring seal. This fitting is designed for potable water
applications and should be replaced with a suitable fitting if chiller is
used with more aggressive liquids.
5 YEAR LIMITED WARRANTY on the refrigeration system of
the unit. Electrical components and water system are warranted for
12 months from date of installation. Warranty pertains to drinking
water applications only. Non-drinking water applications are not
covered under warranty.
Sample Certificate available on request.
Note: In keeping with our policy of continuing product improvement,
Elkay reserves the right to change materials, design and specifications without notice.
Elkay Electric Air Cooled Water Chillers are listed by Underwriters
Laboratories, approved by C.S.A., rated in accordance with A.R.I.
Standard 1010 and meet all known federal and state plumbing codes.
STANDARDS
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc. and comply with
both Canadian and U.S. requirements.
Rated in accordance with A.R.I. Standard 1010
and meets all known federal and state plumbing
codes.
This cooler is certified by WQA to lead-free compliance
including NSF/ANSI 61 and 372.
Elkay Manufacturing Company
www.elkay.com
This specification describes an Elkay product with design, quality and functional benefits to the
user. When making a comparison of other producers' offerings, be certain these features are
not overlooked.
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.
©2012 Elkay Mfg. Co.
(Rev. 7/12) 13-5D
No Lead Remote Chiller
Air Cooled
Model ER-10
ROUGH-IN DIMENSIONS
77/8"
(200 mm)
11/2"
(38 mm)
61/4"
13
/16"
(21 mm)
3
/8" O.D. TUBING
COLD WATER OUT
1
1
/4"
(32 mm)
(159 mm)
TOP VIEW
191/2"
(495 mm)
3
/8" O.D. TUBING
WATER INLET
ADJ. COLD CONTROL
11/4"
(32 mm)
®
22"
(559 mm)
ELECTRICAL
3
/8" O.D. TUBING
TANK DRAIN
FRONT VIEW
Drain Plug: This chiller is provided with a plastic drain plug which incorporates an
o-ring seal. This fitting is designed for potable water applications and should be
replaced with a suitable fitting if chiller is used with more aggressive liquids.
It is important to insure proper ventilation. Allow a minimum clearance of 6
NOTE:
inches (152 mm) in front and 3 inches (76 mm) in the rear of the unit. If unit
is to be installed in an enclosure, allow the following clearances around unit:
1 inch (25 mm) each side, 3 inches (76 mm) in the rear, 3 inches (76 mm)
above. Wall grill, EG-1 or EG-2 may be used with this unit.
SIDE VIEW
Elkay Manufacturing Company
13-5D (Rev. 7/12)
2222 Camden Court
Oak Brook, IL 60523
Printed in U.S.A.