Two S tation Wall M o u nt W a t e r C ool e r (R e ve rs e d)
®
S P E C I F I C A T I O N S
G E NE R AL
S elf-c ontained, double wall hung elec tric refrigerated, water
cooler. Capacity 8.0 G PH of 50° F drinking water, bas ed upon
80°F inlet wa ter and 90°F ambient.
All models have a hooded stream projec tor with self clos ing
pus h bars on front and both right and left sides. Flow regulator provides cons tant stream from 20 to 105 psi water pres sure. Bubbler orifice fully protected to meet all s anitary codes.
OT E: M inimum 40 psi supply line pressure required in spe-
N
cial c ircumstances where both sides of bi-level are in use
simultaneously to ens ure adequate stream height. Does not
apply to non-refrigerated units .
Pressurized s tainless steel evaporator/s torage tank for long
life. Waterways are certified NS F/ANS I 61, far exceeding the
requirements of the Safe Drinking Water Ac t. S tainles s s teel
water tank is lo
subject to line pres sure only when push bar is press ed.
DA C OM P LIA NT
A
These Water C oolers c omply with the requirements of A.D. A.
(Americ ans with Disabilities Act) when properly installed. Als o
meets the guidelines for children’s environments providing
the floor to orifice height is 30" or less and proper clear floor
s pace is provided for paralle l approac h. (B as ed on
Architectural and Transportation B arriers C ompliance B oard
final ruling.) C heck L ocal a nd S tate Codes .
NO L E AD DE S IGN
These Water Coolers are certified to be lead-free as defined
by the S afe Drinking Water Ac t. Elkay Water C oolers are manufac tured with a waterway s ystem utilizing c opper components and completely lead-free materials. T hes e waterways
have no lead becaus e all lead materials, such as leaded
brass , have been removed. All joints are brazed using silver
solder only. N o lead s older is permitted. A s trainer with an
easily cleanable screen is provided to allow trapping and convenient removal of waterborne particulate of 140 microns and
larger prior to their entry into the water cooler.
C
APAC I T IE S C HAR T
Model Volt./ Base 70°F 80°F 90°F Rated Load Filler Filter Lbs.
Number Hertz Rate (21°C) (27°C) (32°C) Watts Amps Option Option (Kg.)
EMABFTLR8C
EMABFTLRDDC – – – – – – – No Yes 70
**B ased on 80° F (27°C ) inlet water temperature.
R ated watts shown are bas ed on operational (run) time, in c ompliance with A.R. I.
S tandard 1010 cond itions. S pec ific applications will determine the ac tual watts
consumed per hour. W atts consumed will be ba sed on number of people
served per hour (us age), ambient tempera tures , a nd inlet water temperature.
OOLIN G S YS T E M
C
Motor C ompres s or : Hermetically sealed, rec iprocating type,
115 Volt/60 Hz, single phase. S ealed-in lifetime oil s upply.
E quipped with elec tric cord and three prong molded rubber
plug.
C ondenser: F an cooled, c opper tube with aluminum fins . Fan
motor is permanently lubricated.
C ooling Unit: C ombination tube-tank type. Tube portion is
continuous coil of copper tubing. Fully insulated with E PS
foam which meets Un
ments for self ex tinguishing ma terial.
cated after bubbler valve, so that the tank is
**GPH of 50°F
Drinking Water
Room Temperature °F
115V/
8.0 9.7 8.8 8.0 370 4.0 No Yes 92
60Hz
Full Glass Wt.
derwriters L aboratories Inc. require-
Ship.
B a r r i e r- F re e A cc es s (A dult or C h i ld)
NS F/ANS I 6 1 C om pliant
M o de l s E M AB FT L R 8 C a nd E M AB F T L R D D C
Mod el E MAB FT LR 8C
R efrigerant Control: R efrigerant HF C -134a is c ontrolled by
ac curately ca librated capillary tube for positively trouble- free
operation.
Tempe ra ture C ontrol: E nclosed a djustable thermostat is
fac tory preset. R equires no adjus tment other than for altitude
requirements. Eas ily access ible.
ONS T R UC T IO N
C
Fra me : G alvanized structural s teel chass is supports fountain
top and c abinet pa nels .
Fountain Top: S eries 300 one piece stainles s s teel top,
polis hed to a uniform E lkay bright luster finish. B as in has
embossed bubbler pad.
E xc lus ive Flex i-Guard
utilizes a pliable polyester elas tomer to prevent acc idental
mouth injuries. Flex on impac t, then returns to original position. S trong. Abra sion-resis tant. Anti-sweat. B ubbler meets
UL requirements and all s anitary c odes and is keyed in location to prevent rotation.
C abinet: C abinet des ign allows for flush to wall mounting. No
rec ess spac e is required. Inc ludes bottom cover plate
fas tened with standard sc rews .
C olor S ele c tion: L ight Gray G ranite furnished as standard.
S tainless steel available at extra c ost.
P rotec ted by Elkay’s 5 Y
eration s ystem of the unit.
E lkay Pres sure-Type Water C oolers are des igned to operate
on 20 psi (138 K Pa) to 105 ps i (724 K Pa) s upply line pres sure.
If inlet pres sure is above 105 psi (724 K P a), a pres sure
regulator mus t be ins talled in the s upply line. Any damage
caus ed by reas on of connec ting this product to supply line
pres sures lower than 20 psi (138 KPa) or higher
(724 K Pa) is not c overed by the warranty.
TAND AR D S
S
Elkay Electric Air Cooled Water Coolers are listed
by Underwriters Laboratories Inc . and c omply with
both C anadian and U.S . requirements.
These units comply with A.R .I. S tandard 1010.
This cooler is certified by WQA to lead-free complianc e including
NSF/ANS I 61-AN NE X G , AB 1953.
®
S afety B ubbler: Innovative des ign
ea r Limited Wa rra nty on the refrig-
than 105 psi
In ke eping with ou r policy of co ntinuing pro duct imp rovement, Elkay reser ves the right to c hange
produc t sp ecifica tions without notice. Please visit elkay.com for most current version of Elkay product
specication sheets.
E lkay
elka y.com
2222 Camden C ourt
Oa k Brook, IL 60523
This s pecific ation d esc ribes an E lkay produc t with design, qua lity and functiona l bene fits to the
use r. W hen ma king a compar ison of other p roducers ’ offerings, be certain thes
overlook ed.
Printed in U.S .A.
© 2011 E lkay
(R ev. 7/14) 12-54D
e f eatures are not
![](/html/79/790c/790cdce44a5c3891ba19a45f5e0ce5daea94169274a2354b187da1b97ffd42f8/bg2.png)
Two Station Wall Mount Water Cooler (Reversed)
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
AB
C
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
I
NLET
NOTE: WATERFLOW
DIRECTION
SERVICE STOP
(NOT FURNISHED)
3/8" O.D. TUBE CONNECT
COLD WATER SUPPLY
1/4" O.D. TUBE
WATER INLET
TO COOLER
BUILDING WATER
I
NLET
5/16" (8mm) DIA.
(10 HOLES)
LEGEND:
A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL.
ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
E
F
D
E
A
F
HANGER BRACKET
C
FINISHED FLOOR
B
1-3/8"
(35mm)
1-3/8"
(35mm)
5-3/4"
(146mm)
5 3/4"
146mm
18-1/16"
(459mm)
1-3/8"
(35mm)
1
-3/8"
(35mm)
2-5/8"
(67mm)
5
-3/4"
(146mm)
5-3/4"
(146mm)
27"
(686mm)
2-7/16"
(63mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
26-11/16"
(678mm)
31-11/16"
(805mm)
7-1/4"
(185mm)
37-1/2"
(951mm)
4-9/16"
(116mm)
11/16"
18mm
12-5/16"
(313mm)
6-3/4"
(171mm)
4-3/4"
(121mm)
8"
(203mm)
18-5/8"
(
473mm)
31-7/8"
(810mm)
RIM
HEIGHT
2-9/16"
(65mm)
6-1/2"
(165mm)
18-3/4"
(476mm)
5"
(127mm)
10"
(254mm)
5"
(127mm)
13-7/8"
(352mm)
20-3/8"
(517mm)
33"
(838mm)
ORIFICE
HEIGHT
39-1/2"
(1003mm)
ORIFICE
HEIGHT
5/16" (8mm) DIA.
(10 HOLES)
LEGEND:
A = RECOMMENDED W
3" (76mm) MAXIMUM OUT FROM WALL.
ATER SUPPLY LOCATION. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8" O.D. UNPLATED COPPER TUBE.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/2" O.D. DRAIN
C = 1-1/2" TRAP NOT FURNISHED
D = ELECTRICAL SUPPLY (3) WIRE RECESSED BOX
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) MIN. CLEARANCE FROM CABINET LOUVERS TO WALL.
F = 7/16" BOLT HOLES FOR FASTENING UNIT TO WALL
ADA REQUIREMENT
*
*
REDUCE HEIGHT BY 3" FOR INSTALLATION OF CHILDRENS ADA COOLER
E
F
D
E
A
F
HANGER BRACKET
C
FINISHED FLOOR
B
1-3/8"
(35mm)
1-3/8"
(35mm)
5-3/4"
(146mm)
5 3/4"
146mm
18-1/16"
(459mm)
1-3/8"
(35mm)
1
-3/8"
(35mm)
2-5/8"
(67mm)
5
-3/4"
(146mm)
5-3/4"
(146mm)
27"
(686mm)
2-7/16"
(63mm)
3-1/2"
(89mm)
4-1/2"
(114mm)
26-11/16"
(678mm)
31-11/16"
(805mm)
7-1/4"
(185mm)
37-1/2"
(951mm)
4-9/16"
(116mm)
11/16"
18mm
12-5/16"
(313mm)
6-3/4"
(171mm)
4-3/4"
(121mm)
8"
(203mm)
18-5/8"
(
473mm)
31-7/8"
(810mm)
RIM
HEIGHT
2-9/16"
(65mm)
6-1/2"
(165mm)
18-3/4"
(476mm)
5"
(127mm)
10"
(254mm)
5"
(127mm)
13-7/8"
(352mm)
20-3/8"
(517mm)
33"
(838mm)
ORIFICE
HEIGHT
39-1/2"
(1003mm)
ORIFICE
HEIGHT
Barrier-Free Access (Adult or Child)
NSF/ANSI 61 Compliant
Models EMABFTLR8C and EMABFTLRDDC
THIS WATER COOLER HAS BEEN DESIGNED AND BUILT TO PROVIDE WATER TO THE USER
HICH HAS NOT BEEN ALTERED BY MATERIALS IN THE COOLER WATERWAYS. THE
W
ROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
G
WATER LINES IS A COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING
UT MAY ALSO OCCUR AWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE
B
LECTRICAL FEEDBACK INTO A WATER COOLER CREATING AN ELECTROLYSIS WHICH
E
CREATES A METALLIC TASTE OR CAUSES AN INCREASE IN THE METAL CONTENT OF THE
ATER. THIS CONDITION IS AVOIDABLE BY INSTALLING THE COOLER USING THE PROPER
W
ATERIALS AS SHOWN BELOW.
M
THIS WATER COOLER MUST BE CONNECTED TO THE WATER SUPPLY USING A DIELECTRIC
OUPLING. THE COOLER IS FURNISHED WITH A NON-METALLIC STRAINER WHICH MEETS
C
THIS REQUIREMENT. THE DRAIN TRAP WHICH IS PROVIDED BY THE INSTALLER SHOULD ALSO
BE PLASTIC TO COMPLETELY ISOLATE THE COOLER FROM THE BUILDING PLUMBING SYSTEM.
MINIMUM 40 PSI SUPPLY LINE PRESSURE REQUIRED IN SPECIAL CIRCUMSTANCES WHEN BOTH
IDES OF BILEVEL ARE IN USE SIMULTANEOUSLY TO ENSURE ADEQUATE STREAM HEIGHT. DOES
S
OT APPLY TO NON-REFRIGERATED UNITS.
N
ROUGH-IN DIMENSIONS
NSTALLER PLEASE NOTE:
I
IMPORTANT
NOTICE
Elkay
12-54D (Rev. 4/11)
2222 Camden Court
Oak Brook, IL 60523
elkayusa.com
Printed in U.S.A.
©2011 Elkay