Elkay EMABFTLDDLC Specifications

SPECIFICATIONS
PRODUCT SPECIFICATION
Self-contained, wall mount bi-level electric water cooler. Refrigerated EMABFTL8 model offers a chilling capacity of 8 gallons per hour of 50°F drinking water, based upon 80°F inlet water and 90°F ambient. Model EMABFTLDD is non-refrigerated and shall deliver non-chilled drinking water. Light touch front and side pushbar actuation with raised letters for the visually
impaired. Type 300 series stainless steel top, with satin nish resists stains.
Anti-splash ridge reduces splatter. Contoured to insure proper drainage. Unit
shall meet ADA guidelines. Unit shall be lead-free design which is certied to
NSF/ANSI 61 and 372 and meets Federal and State low-lead requirements.
Unit shall be certied to UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Easy-Touch pushbar activation
• Contoured basin minimizes splashing; with integral drain
• Available with Flexi-Guard® Safety bubbler or Vandal-resistantt bubbler (tincludes “VR” code in model no. see chart below)
• Valve with built-in ow regulator to provide constant stream from 20 to
105 psi water pressure
• Finish options: Impact-resistant vinyl coating or stainless steel
• Rated for Indoor use
COOLING SYSTEM (Model EMABFTL8 only)
• Compressor: Hermetically-sealed, reciprocating type, single phase. Sealed-in lifetime lubrication.
Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is permanently lubricated.
• Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous copper tubing with stainless steel tank. Fully insulated with EPS foam that meets UL requirements for self-extinguishing material
• Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is factory preset. Requires no adjustment other than for altitude requirements.
Non-Filtered Wall Mount Water Cooler
*Please see table below for entire sku
RATED FOR INDOOR USE ONLY
CONSTRUCTION
• Stainless Steel basin with integral drain
• Galvanized structural steel cooler chassis provides structural integrity
• Cooler cabinet available as Light Gray Granite Vinyl Clad Steel or Stainless Steel (additional cost) construction
• Exclusive Flexi-Guard® Safety Bubbler (option) utilizes an infused anti-microbial pliable polyester elastomer to prevent accidental mouth injuries. Flexes on impact.
• Vandal-resistantt bubbler (option) is one-piece, heavy-duty construction
Warranty: 5 year limited warranty on the unit’s refrigeration system. Electrical components and water system are warranted for 12 months from date of installation or 18 months from factory shipment,
whichever date falls rst.
CAPACITIES CHART
Model
EMABFTL(VR)8*C 115V / 60Hz 8 GPH 4.0 370 80 lbs.
EMABFTL(VR)DD*C
`
Please use this table for the complete sku to order. *Please add the color code of (L) Light Gray Granite or (S) Stainless Steel for the cooler wrapper for your complete sku.
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
Voltage /
Hertz
Chilling**
Capacity
F.L.
Amps
Oak Brook, IL 60523
Rated
Watts
1.0 15 53 lbs.
2222 Camden Court
630-572-3192
elkay.com
Approx.
Ship
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer’s offerings, be certain these features are not overlooked.
Wt.
UL399 and
CAN/CSA 22.2
No. 120
Certied
ADA
COMPLIANT
NSF/ANSI
61 and 372
Certied
© 2015 Elkay
SPEC12-53 (09/2015)
Non-Filtered
Open space rough-in design permits new installation or replacement of existing fountains and coolers with this Elkay cooler when rough-in is within the outline shown.
IMPORTANT! INSTALLER PLEASE NOTE:
This water cooler has been designed and built to provide water to the user which has not been altered by materials in the cooler waterways.
The grounding of electrical equipment such as telephone, computers, etc to water lines is a common procedure. This grounding may be in the building or occur away from the building. This grounding can cause electrical feedback into a water cooler creating an electrolysis which creates a metallic taste or causes an increase in the metal content of the water. This condition is avoidable by installing the cooler using the proper materials as shown below.
Wall Mount Water Cooler Models EMABFTL8* and EMABFTLDD*
1 3/8" 35mm
NOTICE
1 3/8" 35mm
18 1/16" 459mm
5 3/4" 146mm
5 3/4" 146mm
5 3/4" 146mm
This water cooler must be connected to the water supply using a dielectric coupling. The cooler is furnished with a non-metallic strainer which meets this requirement. The drain trap, which is provided by the installer, should also be plastic to completely isolate the cooler from the building plumbing system.
Model shown with Flexi-Guard® bubbler.
5 3/4" 146mm
5/16" (8mm) DIA. (10 HOLES)
ROUGH-IN DIMENSIONS
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
2 5/8" 67mm
RATED FOR INDOOR USE ONLY
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
18 5/8" 473mm
HANGER BRACKET
1 3/8"
1 3/8"
35mm
35mm
3 1/2" 89mm
4 1/2" 114mm
37 1/2" 951mm
7 1/4" 185mm
20 3/8" 517mm
6 1/2" 165mm
E
2 9/16" 65mm
F
4 9/16" 116mm
5" 127mm
FINISHED FLOOR
11/16" 18mm
2 7/16" 63mm
10" 254mm
B
6 1/4" 159mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND: A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept 3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall. B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain. Drain stub 2” (51mm) out from wall. C = 1-1/4” Trap (not furnished). D = Electrical Supply (3) Wire Recessed Box Duplex Outlet. E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet louvers to wall. F = 7/16” (11mm) Bolt Holes for fastening to wall. NOTE: New Installations Must Use Ground Fault Circuit Interrupter (GFCI)
D
E
A
F
20 1/8" 511mm
18 3/4" 476mm
13 7/8" 352mm
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
39 1/2"
25 1/8" 638mm
1003mm
33" 838mm
31 7/8" 810mm
27" 686mm
8" 203mm
C
4 3/4" 121mm
12 5/16" 313mm
6 3/4" 171mm
Job Name: ____________________________________ Model: _______________________ Qty. ____________ Contact: ______________________________________ Approval Signature: _____________________________ Notes: