EZH2O® Bottle Filling Station
With Single Mechanically-Activated Water Cooler
SPECIFICATIONS
PRODUCT SPECIFICATION
Self-contained, wall hung refrigerated water cooler with bottle lling station.
EMABF8WS shall deliver 8 GPH of 50°F drinking water at 90°F ambient and
80°F inlet water. EMABFDWS shall deliver non-chilled drinking water. Unit
shall have mechanically-activated pushbar operation. Bottle lling unit shall
include an electronic sensor for touchless activation with auto 20-second
shut-off timer. Shall include Green Ticker™ displaying count of plastic
bottles saved from waste. Bottle ller shall provide 1.1-1.5 gpm ow rate with
laminar ow to minimize splashing. Shall include integrated silver ion
anti-microbial protection in key areas. Unit shall meet ADA guidelines. Unit
shall be lead-free design which is certied to NSF/ANSI 61 and 372 and
meets Federal and State low-lead requirements. Unit shall be certied to
UL399 and CAN/CSA 22.2 No. 120.
STANDARD FEATURES
• Sanitary, touchless activation with auto 20-second shut-off (Bottle Fillter)
• Self-closing, mechanically-activated front and side pushbar controls (Cooler)
• Designed for installations where activation of cooler is needed even during
power disruptions
• Integrated Silver Ion Anti-microbial Protection in key areas
• Quick Fill Rate: 1.1 gpm (EMABF8WS); 1.5 gpm (EMABFDWS)
• Laminar Flow provides minimal splash
• Real Drain System eliminates standing water
• Visual User Interface display includes:
• Innovative Green Ticker™ counts bottles saved from waste
• Available with Flexi-Guard® Safety Bubbler
• Cooler panel nishes: Light Gray Granite Vinyl Clad Steel or Stainless Steel
Models EMABF8WS and EMABFDWS
RATED FOR INDOOR USE ONLY
Model EMABF8WSLK
or EMABFDWSLK
COOLING SYSTEM (Model EMABF8WS only)
• Compressor: hermetically-sealed, reciprocating type, single phase.
Sealed-in lifetime lubrication.
• Condenser: Fan cooled, copper tube with aluminum ns. Fan motor is
permanently lubricated.
• Cooling Unit: Combination tube-tank type. Self-cleansing. Continuous
copper tubing with stainless steel tank. Fully insulated with EPS foam which
meets UL requirements for self-extinguishing material.
• Refrigerant Control: Refrigerant R134a is controlled by accurately calibrated
capillary tube.
• Temperature Control: Easily accessible enclosed adjustable thermostat is
factory preset. Requires no adjustment other than for altitude requirements.
CAPACITIES CHART
Model Voltage / Hertz
EMABF8WS*K 115V / 60Hz 8 GPH 4.0 370 75
EMABFDWS*K - - 1.0 15 40
*Color code of (L) Light Gray Granite or (S) Stainless Steel cooler panels
**Based on 80°F inlet water & 90°F ambient air temp for 50°F chilled drinking water.
Warranty: 5 year limited warranty on the unit’s refrigeration system.
Electrical components and water system are warranted for 12 months
from date of installation or 18 months from factory shipment, whichever date
falls rst.
Chilling**
Capacity
F.L.
Amps
Rated
Watts
Approx.
Ship
Weight.
CONSTRUCTION
• Stainless Steel basin with integral drain and embossed
bubbler pad
• Galvanized structural steel cooler chassis provides
structural integrity
• Cooler cabinet available as Light Gray Granite
Vinyl Clad Steel or Stainless Steel (additional cost)
construction
• Flexi-Guard® Safety Bubbler utilizes an infused
anti-microbial pliable polyester elastomer to prevent
accidental mouth injuries. Flexes on impact.
CERTIFICATIONS / STANDARDS
• ADA Compliant
• UL399 and CAN/CSA 22.2 No. 120 Certied
• ANSI/NSF 61 and 372 Certied
• GreenSpec® Listed
This specication describes an Elkay product with design, quality
and functional benets to the user. When making a comparison
of other producer’s offerings, be certain these features are not
overlooked.
In keeping with our policy of continuing product
improvement, Elkay reserves the right to change
specication without notice. Please visit elkaypro.com
for the most current version.
2222 Camden Court
OakBrook, IL 60523
630-572-3192
elkay.com
© 2014 Elkay
SPEC00082 (09/2014)
EZH2O® Bottle Filling Station
With Single Mechanically-Activated Water Cooler
Models EMABF8WS and EMABFDWS
1/4” O.D. TUBE
WATER INLET
TO COOLER
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
52 1/16"
1323mm
39 1/16"
991mm
787mm
3/8” O.D. TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATERFLOW
DIRECTION
TUBE IS SECURED
TUBE IS SECURED
B CA
7/16"
11mm
MOUNTING HOLES
(6)
ACTIVATION
SENSOR
5/16" (8mm) DIA. (5 HOLES)
31"
25"
635mm
21 3/8"
543mm
IN POSITION
IN POSITION
O
5 3/4"
146mm
1 3/8"
35mm
E
18 3/8"
467mm
SERVICE STOP
(NOT FURNISHED)
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
178mm
B
D
A
5"
127mm
BUILDING WATER
INLET
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
RELEASE TUBE
RELEASE TUBE
17 7/8"
454mm
7"
C
L
254mm
7"
178mm
11/16"
18mm
2 1/2"
64mm
2 7/16"
63mm
4 1/2"
114mm
10"
3 1/2"
89mm
4 9/16"
116mm
F
13 7/8"
352mm
ROUGH-IN DIMENSIONS
IMPORTANT!
This water cooler has been designed and built to provide water to the user which
has not been altered by materials in the cooler waterways. The grounding of
electrical equipment such as telephone, computers, etc., to water lines is a
common procedure. This grounding may be in the building but may also occur
away from the building. This grounding can cause electrical feedback into a
water cooler creating an electrolysis which creates a metallic taste or causes
an increase in the metal content of the water. This condition is avoidable by
installing the cooler using the proper materials as shown below.
This water cooler must be connected to the water supply using a dielectric
coupling. The cooler is furnished with a non-metallic strainer which meets this
requirement. The drain trap which is provided by the installer should also be
plastic to completely isolate the cooler from the building plumbing system.
Bottle Filler unit will mount on bracket attached to wall by 6 holes (as shown).
Water and electrical will connect through pre-punched hole in basin.
5 3/4"
146mm
15"
381mm
3 3/16"
82mm
1 3/8"
35mm
E
7 1/4"
185mm
2 9/16"
65mm
FINISHED FLOOR
INSTALLER PLEASE NOTE
NOTICE
2 5/8"
67mm
33"
838mm
ORIFICE
HEIGHT
31 13/16"
808mm
RIM
HEIGHT
27"
686mm
ADA
REQUIREMENT
8"
203mm
6 1/4"
159mm
3 9/16"
90mm
18 1/2"
471mm
HANGER BRACKET
C
12 5/16"
313mm
1 1/2"
38mm
6 3/4"
172mm
18 7/8"
479mm
REDUCE HEIGHT BY 3 INCHES FOR INSTALLATION OF CHILDRENS ADA COOLER
LEGEND:
A = Recommended Water Supply location. Shut-off Valve (not furnished) to accept
3/8” O.D. unplated copper tube. Up to 3” (76mm) maximum out from wall.
B = Recommended Waste Outlet location. To accommodate 1-1/4” nominal drain.
Drain stub 2” (51mm) out from wall.
C = 1-1/4” Trap (not furnished).
D = Electrical Supply (3) Wire Recessed Box Duplex Outlet.
E = Insure proper ventilation by maintaining 6” (152mm) minimum clearance from cabinet
louvers to wall.
F = 7/16” (11mm) Bolt Holes for fastening to wall.
**New Installations Must Use Ground Fault Circuit Interrupter (GFCI).
2222 Camden Court
Oak Brook, IL 60523
elkay.com
Job Name: ____________________________________
Model: _______________________ Qty. ____________
Contact: ______________________________________
Approval Signature: _____________________________
Notes:
Printed in U.S.A.
© 2014 Elkay