Elkay EHW217FPK Specifications

Page 1
Heavy Duty 14 Gauge Drinking Fountain
Freeze Resistant, Wall Mount, Fully Exposed
PRODUCT SPECIFICATION
Wall mounted freeze-resistant drinking fountain constructed of #14
gauge, type 304, stainless steel polished to a lustrous satin nish.
Contoured basin minimizes splashing and has vandal-resistant bubbler. Keyed in location to prevent rotation. Easy to operate, fully functional chrome plated push button is vandal-resistant. Bottom cover plate included. Flow regulator provides constant stream from 20 to 105 psi water pressure.
Includes freeze-resistant box LKFRB1 to be mounted on an interior heated wall where the temperature does not drop below 50°F (10°C).
Complies with the requirements of A.D.A. (American’s with Disabilities Act) when properly installed.
NO LEAD DESIGN
THIS DRINKING FOUNTAIN COMPLIES WITH THE LEAD-FREE DEFINITION IN THE SAFE DRINKING WATER ACT OF 1986 AND LEAD CONTAMINATION CONTROL ACT OF 1988.
Elkay Drinking Fountains are manufactured with a waterway system utilizing copper components and completely lead-free material. These waterways have no lead because all leaded materials, such as leaded brass, have been removed.
This fountain is certied by WQA to lead-free compliance including
NSF/ANSI 61 and 372.
CONSTRUCTION
EHWM217FPK furnished complete with vandal-resistant
bubbler and easy to operate, vandal-resistant front push-button.
Patented* valve and in-line ow regulator provides stream from
(20-105 psi). Stainless steel wall plate with surface mounting plate and vandal-resistant 14 gauge bottom cover plate included.
EHW217FPK does not include the surface mounting plate. To be mounted with MPW200 in-wall mounting plate. ML100 in-wall support legs are optional.
MPW200 In-wall carrier (ordered separately) constructed of heavy-gauge steel. Plate can be installed directly to studs or with optional ML100 support legs. All parts painted with a protective coating to last.
LKFRB1 includes box with separate front louvered panel. Flow regulator provides constant stream from 20 to 105 psi water pressure. Operated by adjustable cable system. Trap and drain tube included for proper installation.
INSTALLER NOTE
THIS DRINKING FOUNTAIN IS FURNISHED WITH A BUBBLER AND VALVE INCLUDING ALL CONNECTING FITTINGS WHICH ARE MANUFACTURED OF COMPLETELY LEAD FREE MATERIAL. IT IS RECOMMENDED THAT SHUT OFF VALVE AND SUPPLY TUBING SUPPLIED BY OTHERS BE NON-METALLIC.
In keeping with our policy of continuing product improvement,
Elkay reserves the right to change specication without notice. Please visit elkay.com for the most current version.
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
This specication describes an Elkay product with design, quality and functional benets to the user. When making a comparison of other producer ’s offerings, be certain these features are not overlooked.
© 2015 Elkay
SPEC00433 (09/2015)
Page 2
Heavy Duty 14 Gauge Drinking Fountain Freeze Resistant, Wall Mount, Fully Exposed Models EHW217FPK & EHWM217FPK
INSTALLER NOTE
THIS DRINKING FOUNTAIN IS FURNISHED WITH A BUBBLER AND WATERWAY WITH ALL CONNECTING FITTINGS WHICH ARE MANUFACTURED OF COMPLETELY LEAD FREE MATERIAL. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8” O.D. UNPLATED COPPER TUBE.
ROUGH-IN DIMENSIONS
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B C
B CA
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
When installing EHWM217FPK which includes a surface mounting plate, refer to the diagrams below.
For electrical, waste, and water supply locations refer to the Installation/Owners manual.
EHWM217FPK WITH SURFACE MOUNTING PLATE
MOUNTING BOLT AND ACCESS HOLE LAYOUT
18 3/4" 476mm
2 3/4"
12 1/8" 308mm
7 1/4" 185mm
12 1/8" 308mm
7 1/4" 185mm
WALL PLATE ASSEMBLY
"E"
3" 76mm
5 1/4" 133mm
5 1/4" 133mm
"C"
70mm
3" 76mm
5 1/4" 133mm
5 1/4" 133mm
"C"
"D"
7 1/4" 184mm
12" 305mm
MAX. WALL
THICKNESS
26 13/16" 681mm
LEGEND:
A = 1-3/4” DIA. (44 mm) HOLE FOR WASTE LINE B = 7/8” DIA. (22 mm) HOLE FOR WATER SUPPLY C = 7/8” DIA. (22 mm) HOLE FOR OPERATING CABLE D = 1/4” DIA. (6 mm) HOLE FOR MOUNTING PLATE TO WALL E = 3/8” DIA. (10 mm) HOLE FOR MOUNTING PLATE TO WALL
Page 2
7 1/4" 184mm
30 1/4" 768mm
29 7/8" 759mm
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
28 9/16" 725mm
24 9/16" 625mm
"B"
"A"
16" 406mm
FINISHED FLOOR
"A"
16" 406mm
44 11/16"
"B"
32 13/16" 833mm
35 7/8" 911mm
34 9/16" 878mm
36 1/4" 921mm
1136mm
Printed in U.S.A.
© 2015 Elkay
Page 3
Heavy Duty 14 Gauge Drinking Fountain Freeze Resistant, Wall Mount, Fully Exposed Models EHW217FPK & EHWM217FPK
EHWM217FPK WITH SURFACE MOUNTING PLATE
ROUGH-IN DRAWING
38 1/2" 978mm
6 11/16" 170mm
12 1/8" 309mm
3 11/16" 94mm
18" 457mm
ROUGH-IN DIMENSIONSROUGH-IN DIMENSIONS
5/8" 16mm
20 3/8" 518mm
6 1/2"
65mm
1
12" 305mm
33" 836mm
ADA
REQUIREMENT
FINISHED FLOOR
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1 and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
27" 686mm
ADA
REQUIREMENT
MAX. WALL THICKNESS
2 5/8" 66mm
3 5/8" 91mm
14 3/16" 360mm
17 11/16" 449mm
20 3/16" 512mm
23 11/16" 601mm
28 9/16" 726mm
34 9/16" 878mm
Page 3
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2015 Elkay
Page 4
Heavy Duty 14 Gauge Drinking Fountain Freeze Resistant, Wall Mount, Fully Exposed For use with In-Wall Carrier MPW200 Models EHW217FPK & EHWM217FPK
ROUGH-IN DIMENSIONS
INSTALLER NOTE
THIS DRINKING FOUNTAIN IS FURNISHED WITH A BUBBLER AND WATERWAY WITH ALL CONNECTING FITTINGS WHICH ARE MANUFACTURED OF COMPLETELY LEAD FREE MATERIAL. SHUT OFF VALVE (NOT FURNISHED) TO ACCEPT 3/8” O.D. UNPLATED COPPER TUBE.
OPERATION OF QUICK CONNECT FITTINGS
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE TO ATTACH
A B C
TUBE IS SECURED
TUBE IS SECURED
IN POSITION
IN POSITION
B CA
PUSH IN COLLET
PUSH IN COLLET
TO RELEASE TUBE
TO RELEASE TUBE
PUSHING TUBE IN BEFORE
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
PULLING IT OUT HELPS TO
RELEASE TUBE
RELEASE TUBE
When installing EHW217FPK with MPW200 in-wall plate mounted directly to wall studs, refer to the diagrams below.
For electrical, waste, and water supply locations refer to the Installation/Owners manual.
EHW217FPK WITH MPW200 MOUNTING PLATE MOUNTING BOLT AND ACCESS HOLE LAYOUT
12 1/8" 307mm
7 1/4" 184mm
12 1/8" 307mm
7 1/4" 184mm
LEGEND:
A = 1-3/4” DIA. (44 mm) HOLE FOR WASTE LINE B = 7/8” DIA. (22 mm) HOLE FOR WATER SUPPLY C = 7/8” DIA. (22 mm) HOLE FOR OPERATING CABLE D = 1/4” DIA. (6 mm) HOLE FOR MOUNTING PLATE TO WALL
43 1/2" 1105mm
BACK PANEL
36 1/4" 921mm
D
1 5/16" 33mm
34 9/16" 878mm
6 5/8" 168mm
B
A
32" 813mm
C
18 3/4" 476mm
FINISHED FLOOR
16" 406mm
3 1/4" 82mm
B
MPW200 MTG. PLT.
1 5/16" 33mm
C
A
30 1/4" 768mm
28 9/16" 725mm
Page 4
2222 Camden Court Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2015 Elkay
Page 5
Heavy Duty 14 Gauge Drinking Fountain Freeze Resistant, Wall Mount, Fully Exposed For use with In-Wall Carrier MPW200 Models EHW217FPK & EHWM217FPK
EHW217FPK WITH MPW200 MOUNTING PLATE
ROUGH-IN DRAWING
38 1/2" 978mm
6 5/8" 168mm
12 1/8" 308mm
3 13/16" 97mm
FINISHED WALL
18" 457mm
ROUGH-IN DIMENSIONS
5/8" 16mm
MPW200 MTG. PLT. REF. SEPARATE INSTALLATION INSTRUCTIONS FOR DETAILS
6 1/2" 165mm
33" 838mm
27" 686mm
ADA
REQUIREMENT
FINISHED FLOOR
12" 305mm
MAX. WALL THICKNESS
2 5/8" 66mm
13" 330mm
3 5/8" 91mm
14" 355mm
17 1/2" 444mm
20" 508mm
23 1/2" 597mm
1. Wall should already be framed for the fountain using dimensions shown in Fig. 1. Shown dimensions pertain to installation location.
These dimensions are required for compliance with ANSI Standard A117.1 and ADA (Framing shown for reference only).
2. Remove bottom cover from fountain and save the screws.
3. Install the fountain using bolts and washers (provided). Tighten securely.
4. Attach drain tube to fountain and cut to required length using the freeze resistant box as a guide.
5. Install freeze-resistant box - see box instructions.
6. Replace bottom cover.
28 9/16" 725mm
34 9/16" 878mm
Page 5
2222 Camden Court
Oak Brook, IL 60523
630-572-3192
elkay.com
Printed in U.S.A.
© 2015 Elkay