Elkay EHOA8-1C Installation Manual

Page 1
EHOA8*1C, 2C
With FLEXI-GUARD
®
Installation/Care/Use Manual
USES HFC-134A REFRIGERANT
46
43, 44,
45
25
21
SEE FIG. 3
27, 47
SEE FIG. 4
49
42
51
53
50
52
39, 40, 41
53
33
22, 23, 24
34
51
35, 36, 3748
20
FIG. 1
PAGE 1
97376C (Rev. C - 10/02)
Page 2
EHOA8*1C, 2C
FINISHED FLOOR
PISO ACABADO
PLANCHER FINI
ASEGURE UNA VENTILACIÓN ADECUADA MANTENIENDO UN ESPACIO E 6" (152mm) (MÍN.) DE HOLGURA ENTRE LA
REJILLA DE VENTILACIÓN DEL MUEBLE Y LA PARED
ASSUREZ-VOUS UNE BONNE VENTILATION EN GARDANT 6" (152mm) (MIN.) ENTRE LES ÉVENTS DE LENCEINTE ET LE
MUR
CABLE ELÉCTRICO DE 1½ PIE, 457 mm DE LARGO
CORDON DALIMENTATION 1-1/2' (457mm)
UBICACIÓN ALT. DE LA TOMA DE ELECTRICIDAD
EMPLACEMENT ALTERNATIF DE LA PRISE DE COURANT
ESTE AGUJERO DE TUERCA DEBERÁ SER USADO PARA ASEGURAR LA UNIDAD A LA PARED.
ON DOIT UTILISER CE TROU DE BOULON POUR INSTALLER LAPPAREIL AU MUR.
ALTURA DEL ORIFICIO 1-1/4" (32mm) SOBRE LA CORONA
HAUTEUR DE L'ORIFICE 1-1/4" (32mm) AUDESSUS DU REBORD
E = INSURE PROPER VENTILATION BY MAINTAINING 6" (152mm) (MIN.) CLEARANCE FROM CABINET LOUVERS TO WALL.
F = POWER CORD 1-1/2FEET (457mm) LONG
G = ALT. ELECTRICAL OUTLET LOCATION
H = THIS BOLT HOLE MUST BE USED FOR FASTENING UNIT TO WALL.
J = ORIFICE HEIGHT 1-1/4" (32mm) ABOVE RIM
FIG. 2
97376C (Rev. C - 10/02)
PAGE 2
FROM WALL SHUT OFF BY OTHERS
1/2" (38mm) FUERA DE LA LLAVE DE PASO EN LA PARED COLOCADA POR TERCEROS.
CONNECTANT UNE TUYAUTERIE DE 1-1/2 PO. (38mm) DEPUIS LE ROBINET D'ARRÊT FOURNI PAR D'AUTRES.
UBICACIÓN RECOMENDADA PARA EL DRENAJE DE SALIDA DE AGUA, DE 1¼ DE DIÁMETRO.
EMPLACEMENT RECOMMANDÉ POUR LE DRAIN DE D.E. 1-1/4" DE SORTIE DEAU.
PURGADOR DE 1¼ NO PROPORCIONADO**
SIPHON 1-1/4 NON FOURNI**
UBICACIÓN DE LA TOMA DE ELECTRICIDAD
SE RECOMIENDA UBICAR EL TUBO CORTO DE CONEXIÓN AL TUBO DE COBRE SIN CHAPAR DE 3/8" DE DIÁM. EXT. A 1-
LEGEND/LEYENDA/LÉGENDE
A = RECOMMENDED WATER SUPPLY LOCATION 3/8 O.D. UNPLATED COPPER TUBE CONNECT STUB 1-1/2 IN. (38mm) OUT
EMPLACEMENT RECOMMANDÉ D'ALIMENTATION EN EAU PAR TUBE EN CUIVRE NON PLAQUÉ DE 3/8 PO. (9,5 mm) D.E.
B = RECOMMENDED LOCATION FOR WASTE OUTLET 1-1/4 O.D. DRAIN
C = 1-1/4 TRAP NOT FURNISHED**
EMPLACEMENT DE LA PRISE DE COURANT
D = ELECTRICAL OUTLET LOCATION
Page 3
EHOA8*1C, 2C
SENSOR RANGE ADJUSTMENT: The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36 inches (914 mm). If actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure below: A. Remove front panel of cooler. B. Using a small tip screwdriver, rotate range adjustment screw clockwise to increase range and counterclockwise to decrease range (See Fig. 3). CAUTION: Complete range of sensor (24-28 inches/610-711mm) is only one turn of the adjusting screw. C. Replace front panel. SENSOR CONTROL: If sensor fails to operate valve mechanism or operates erratically, check the following. A. Ensure there are no obstructions within a 40 inch (1016mm) radius in front of cooler. B. Check wire connections at the solenoid valve and sensor. CAUTION: Make sure unit is unplugged before checking any wiring. C. Ensure proper operation of solenoid valve. If there is an audible clicking sound yet no water flows, look for an obstruction in the valve itself or elsewhere in the water supply line.
13
RANGE ADJUSTMENT SCREW
10
3
16
NOTE: WATER FLOW DIRECTON
15
6
14
FIG. 3
14
7
HANGER BRACKETS & TRAP
INSTALLATION
1) Remove hanger bracket fastened to back of cooler by re-
moving one (1) screw.
2) Mount the hanger bracket and trap as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely. Add
fixture support carrier if wall will not provide adequate sup­port.
IMPORTANT:
7-3/4 in. (197mm) dimension from wall to centerline of trap
must be maintained for proper fit.
Anchor hanger securely to wall using all six (6) 1/4 in. dia.
mounting holes.
3) Install straight valve for 3/8" O.D. unplated copper tube.
INSTALLATION OF COOLER
4) Hang the cooler on the hanger bracket. Be certain the hanger bracket is engaged properly in the slots on the cooler back as shown in Figure 2.
5) Loosen the two (2) screws holding the lower front panel at the bottom of cooler base and two (2) screws at the top. Remove the front panel and set aside.
6) Connect water inlet line--See Note 4 of General Instruc­tions.
7) Remove the slip nut and gasket from the trap and install them on the cooler waste line making sure that the end of the waste line fits into the trap. Assemble the slip nut and gasket to the trap and tighten securely.
START UP
Also See General Instructions
8) Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, adjust screw, ac­cessible by removing front panel (Item 7, Fig. 3). CW adjustment will raise stream and CCW adjustment will lower stream. For best adjustment, stream should hit basin approximately 6-1/2 (165mm) from bub­bler.
9) Replace the front panel and secure by retightening four (4) screws.
12
11
2
1
4
ITEM NO. PART NO.
1 2 3
4
5 6 7 8
9 10 11 12 13 14 15 16 17
PANEL
COLOR
Gray Beige Almond Stainless Stl Sandalwood Granite Light Gray
8
17
9
9
14
26588C 26866C 31516C 35783C 31272C
35784C See Color Table See Color Table See Color Table
70817C
75507C
56082C
70644C
75497C
40045C
70864C
50986C
61314C
70002C
COLOR TABLE
Item No. 5
Part No.
26635C
26636C
26637C
26638C
26641C
26642C
5
DESCRIPTION
Panel-Bottom Dispenser Bracket-Valve Mounting Sensor-Clear (115V) Sensor-Clear (230V) Solenoid Valve (115V) Solenoid Valve (230V) Panel-Right Side Panel-Left Side Panel-Front Elbow 1/4 Stem x 1/4 O.D. Fitting 1/4 NPTF x 1/4 O.D. Nut-Regulator Screw-#6-32 x 1/2" Lg. PHMS Screw-#10 x 1/2" Lg. PHSM Hex Nut Screw-#8 x 5/8" Lg. Torx/Slot Holder-Regulator Regulator Screw-#10 x 1/2" Lg. HHSM
Item No. 6
Item No. 7
Part No.
26605C 26606C 26607C 26608C 26611C 26612C
Part No.
26731C 26732C 26733C 26734C 26737C 26738C
PAGE 3
97376C (Rev. C - 10/02)
Page 4
EHOA8*1C, 2C
PARTS LIST 115V
ITEM NO. PART NO.
18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
38*
39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
27097C
See Color Table
31483C 27095C 30699C 70018C 31490C 70009C 50186C 70241C 56073C 40322C 55997C 56011C 75580C 62152C 66202C 50144C 70184C 70150C 35947C 31039C 35768C 35935C 66501C 40572C 40575C 50074C 21222C 70208C 31513C 66505C 55996C 27093C 27094C 27096C 56092C
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water coolers or orders for repair parts MUST include Model No. and Serial No. of cooler, name and part number of replacement part.
Frame-Back/Bottom Wrapper Power Cord Fan Bracket Fan Blade Hex Nut - Fan Blade Fan Motor 115V Screw - Fan Motor Shroud - Fan Clip (Front and Rear Panels) Bubbler Assembly Orifice Assembly Pedestal Housing Assembly Locknut Condenser Drier Grommet - Compressor Mtg. Hair Pin - Cotter Washer Compressor Serv. Pak EM65 Overload/Relay P600B/427NFBYY Cover - Relay Capacitor - Run Heat Exchanger Tailpipe Strainer Assy Gasket - Tailpipe Basin Screw - Basin Mtg. Cold Control Evaporator Assy Strainer Angle - Bracket Corner Bracket - Front Support Bracket - Basin Mtg. Poly Tubing (Cut To Length)
DESCRIPTION
PARTS LIST 230V
ITEM NO. PART NO.
24
*38
40 41 42
-
31430C 35763C 31024C 35768C 66552C
194243901550
WIRING DIAGRAM
This Drawing is merely for illustrating the
components of the electrical system.
30
28
29
DESCRIPTION
Fan Motor Compressor Serv. Pak Overload/Relay Cover-Relay Heat Exchanger Cover-Electrical Shield
31
BASIN
PANEL
COLOR
Gray Beige Almond Stainless Steel Sandalwood Granite Light Gray
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523  630.574.8484
97376C (Rev. C - 10/02)
COLOR TABLE
Item No. 55
Part No.
22706C 22707C 22708C 22709C 22711C 22712C
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4
32
NOTE: WHEN INSTALLING REPLACEMENT BUBBLER AND PEDESTAL, TIGHTEN NUT (ITEM 32) ONLY TO HOLD PARTS SNUG IN POSITION. DO NOT OVER TIGHTEN.
FIG. 4
Loading...