Elkay ECH8-1A User Manual

ECH8-1A ECH8-2A
Installation / Care / Use Manual
Refrigeration Package
INSTALLATION
1. When mounting unit in an open area, to insure proper ventilation, maintain a 4" (102mm) clearance from cabinet louvers on each side of cooler . When mounting unit in a cavity or behind a wall maintain minimum space of 4" (102mm) on each side, 4" (102mm) on the top and a depth of 12" (305mm).
2. Water inlet is 1/4" (6 mm) O.D. tube. Contractor to supply the connections as required.
3. Connecting lines to be of unplated copper, thoroughly flushed to remove all foreign matter before being connected to cooler. If flushing does not remove all particles, a water strainer should be installed in supply line. This cooler is manufactured in such a manner that it does not in any way cause taste, odor, color or sediment problems. If a taste, odor or sediment problem is prevalent, try installing our waste filter module, Part No. 73-15242-51-550, on the supply line.
4. Connect cooler to building supply line with a shut-off valve and install a union connection between the valve and cooler
5. Electrical: Make sure power supply is identical in voltage, cycle, and phase to that specified on cooler serial plate. Never wire compressor directly to the power supply.
6. This chiller has been designed for use with potable water ONLY.
LEGEND A = 3/8" O.D. TUBE WATER OUTLET B = 1/4" O.D. TUBE WATER INLET C = TEMPERATURE ADJUSTMENT D = ELECTRICAL
START-UP
1. Open supply line valve.
2. Purge air from all water lines by operating bubbler valve of fountain to which cooler is connected. Steady stream assures all air is removed.
3. Rotate fan to insure proper clearance and free fan action.
4. Connect to electrical power.
TROUBLE SHOOTING & MAINTENANCE
Temperature Control: Factory set at 50°F (± 5°) under normal conditions. For colder water, adjust screw on item no. 12 in clockwise direction. Ventilation: Cabinet louvers and condenser fins should be periodically cleaned with brush, air hose or vacuum cleaner. Excess dirt or poor ventilation can cause no cold water and compressor cycling on the compressor overload protector.
Lubrication: Motors are lifetime lubricated. Actuation of Quick Connect Water Fittings: Cooler is provided
with lead-free connectors which utilize an o-ring seal. To remove tubing from the fittings, relieve water pressure, push in on gray collar while pulling on the tubing. To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4.
OPERATION OF QUICK CONNECT FITTINGS
SIMPLY PUSH IN
TUBE TO ATTACH
TUBE IS SECURED
IN POSITION
PUSH IN COLLET
TO RELEASE TUBE
PUSHING TUBE IN BEFORE PULLING IT OUT HELPS TO
RELEASE TUBE
97382C (Rev. A - 5/99)
ITEMIZED PARTS LIST
ITEM
NO.
10
*11
12 13 14 15 16 17 18 19 20 21 22 23
ITEM
NO.
*11
14
*INCLUDES RELAY & OVERLOAD. IF UNDER WARRANTY, REPLACE WITH SAME COMPRESSOR USED IN ORIGINAL ASSEMBLY.
NOTE: All correspondence pertaining to any of the above water cooler or orders for repair parts MUST include model number and serial number of cooler, name and part number of replacement part.
1 2 3 4 5 6 7 8 9
100806740570 101516143550
4
191555551550 6 9
-
194243901550
PART NO.
66505C 22301C 61942C 31490C 20437C 30699C 70018C 22309C 66530C 66202C 35947C 31513C 22299C 35768C 31039C 35935C
19037000
50930C 27303C 22300C 70745C
PART NO.
31475C 66269C 35809C 35798C
EVAPORATOR TANK ASSY CABINET CONDENSER MOTOR - FAN 115V BRACKET - FAN MOUNTING BLADE - FAN NUT - FAN BLADE SHROUD - FAN HEAT EXCHANGER DRIER COMPRESSOR SERVICE PAK COLD CONTROL PANEL - FRONT COVER - RELAY OVERLOAD/RELAY ASSY CAPACITOR GROMMET STUD - COMP. MOUNTING CLIP BUMPER BASEPLATE PANEL - REAR UNION 1/4 X 3/8
220/240V - 50 HZ
MOTOR - FAN 230V BLADE - FAN HEAT EXCHANGER COMPRESSOR SERVICE PAK COVER - RELAY COVER - ELECTRICAL SHIELD
DESCRIPTION
DESCRIPTION
ECH8-1A ECH8-2A
22
23
3
4,5,6,7,8
2
10
1
PRINTED IN U.S.A.
ELKAY MANUFACTURING COMPANY  2222 CAMDEN COURT  OAK BROOK, IL 60523  630.574.8484
97382C (Rev. A - 5/99)
WIRING DIAGRAM
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
13
20
11,14,15, 16,
9
12
17,18,19
21
Loading...