
ECDFPW314C ECDFPWVR314C
Installation/Care/Use Manual
Soft Sides™ Fountains with FLEXI-GUARD
ECDFPW314C
®
Installer
T o assure you install this model easily and correctly ,
PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE ST ARTING THE
INST ALLATION. CHECK YOUR INST ALLA TION FOR COMPLIANCE WITH
PLUMBING , ELECTRICAL AND OTHER APPLICABLE CODES. After installation, leave
these instructions inside the fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO
WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y
OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK
INTO A FOUNT AIN, CREA TING AN ELECTROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS A VOIDABLE BY USING
THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER
SHOULD BE MADE OF PLASTIC TO ELECTRICALL Y ISOLA TE THE FOUNT AIN FROM THE BUILDING
PLUMBING SYSTEM.
1/4" O.D. TUBE
WATER INLET
TO COOLER
3/8" O.D. UNPLATED
COPPER TUBE CONNECT
COLD WATER SUPPLY
NOTE: WATER FLOW
DIRECTION
BUILDING WATER
INLET
SERVICE STOP
(NOT FURNISHED)
FIG. 2FIG. 1
97749C (Rev. H - 3/05)

ECDFPW314C ECDFPWVR314C
ECDFPW314C
FIG. 3
LEGEND
A = RECOMMENDED W ATER SUPPLY LOCATION 3/8 O.D. UNPLATED
COPPER TUBE CONNECT STUBBED 1-1/2" (38mm) FROM WALL SHUT
OFF BY OTHERS
B = RECOMMENDED LOCATION FOR W ASTE OUTLET 1-1/4" O.D. DRAIN
C = 1-1/4" DRAIN FURNISHED
D = OPENING FOR OPTIONAL AP-99 ACCESS P ANEL.
NOTE: REINFORCE THE WALL IN THE SHADED AREAS
97749C (Rev. H - 3/05)
PAGE 2

ECDFPW314C ECDFPWVR314C
INST ALLATION INSTRUCTIONS
1. Wall should already be framed for the fountain using the positioning dimensions shown in Figure 3. Shown
dimensions pertain to installation location (framing must support up to 300 lbs. weight). These dimensions
are required for compliance with ANSI Standard A117.0.
2. Attach wall plate assembly to wall as shown in Figure 3 using 5/16" x 2" long bolts and flat washers
(not provided). Tighten securely. (Fastener must match wall type, i.e. lag screws for wood studs, bolts and
anchors for masonary construction.)
3. Install back panel. Place the upper edge of the panel above hanger on the wall. Slide panel down until it
engages the hanger. Be sure back panel is firmly engaged before releasing it.
4. Install rough-in plumbing as shown in Figure 3. Waste line should extend a minimum of 2" (51mm) thru the
back panel. Run supply water inlet line thru back panel. Install a service stop (not provided). Turn on supply
water and flush thoroughly.
5. Remove bottom access panel from fountain basin and save the screws. Install the fountain to the back
panel using (4) 5/16" x 3/4" long screws and washers (provided) thru holes in back panel. Tighten securely.
6. Cut waste tube to required length using plumbing hardware and a trap (not provided) as a guide. Install
hardware and trap. Tighten securely.
7. Make water supply connections from service stop to the 3/8" O.D. unplated copper tube coming out of the
fountain strainer (See Fig. 1). Turn on water supply and check for leaks. Newly installed water supply line
should be insulated after leak check is completed. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER
AS DAMAGE TO THE O-RINGS MA Y RESUL T .
8. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above
105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of
connecting these products to supply line pressure lower than 20 PSIG or higher than 105 PSIG is not
covered by warranty.
9. Check stream height from bubbler. Stream height is factory set at 35 PSI.
If supply pressure varies greatly
from this, adjust the screw on regulator item 10 by using a small screwdriver through the small hole
in the push button item 3 (See Fig.5). Clockwise adjustment will raise stream height and counter-clockwise
adjustment will lower stream height. For best adjustment stream should hit basin approximately 6-1/2"
(165mm) from bubbler.
10. Replace bottom access panel to fountain basin using screws provided. Tighten securely.
TROUBLE SHOOTING AND MAINTENANCE
1. Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits
may be removed from orifice with a small round file not over 1/8" diameter or a small diameter wire.
CAUTION: Do not file or cut orifice materials.
2. Stream Regulator: If orifice is free of material deposits, regulate flow according to instruction 9 stated above.
3. Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an
o-ring water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while
pulling on the tubing (See Figure 2). To insert tubing, push tube straight into the fitting until it reaches a
positive stop, approximately 3/4".
PAGE 3
97749C (Rev. H - 3/05)

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
PAR T NO.ITEM NO.
40575C
15005C
45662C
45737C
50986C
40322C
56011C
55997C
75580C
61313C
75672C
112627543890
55996C
55001129
55000665
28290C
40045C
28291C
100322740560
15009C
45392C
56092C
28286C
45679C
45805C
50074C
60295C
45736C
75541C
11 1577243890
PAR TS LIST
DESCRIPTION
Drain - Strainer
Retaining Nut
Push Button
Push Button Sleeve
Regulator Holder
Orifice Assy
Housing Assy
Pedestal
Bubbler Locknut
Regulator
Cap Screw
Screw - #10-24 X .50 PHTC
Strainer
Fountain Arm - Long
Bottom Cover Plate - Long
Back Panel
Hex Nut
Regulator Mounting Bracket
Gasket (VR Model Only)
Bubbler - Nipple (VR Model Only)
Bubbler (VR Model Only)
Poly Tubing (Cut T o Length)
Mounting Plate Assy
Drain Tailpipe
Drain Adapter
Gasket - T ail Pipe
Tube - Water In
Nut-Regulator Mounting
Washer - Flat .339/.359ID Steel
Screw - Mach. 5/16-18 x 3/4
ECDFPW314C ECDFPWVR314C
4
3
11
FIG. 5
FIG. 6
6
18
17
2
10
28
5
FIG. 7
7
21
8
FIG. 8
22
14
SEE FIG. 6 OR 7
13
9
NOTE: WHEN INSTALLING REPLACEMENT
BUBBLER AND PEDESTAL, TIGHTEN NUT
(ITEM 9 OR 20) ONLY TO HOLD PARTS SNUG
IN POSITION. DO NOT OVER TIGHTEN.
16
29, 30
23
19
20
97749C (Rev. H - 3/05)
SEE
FIG. 5
12
27
15
1,24,25,26
ELKAY MANUFACTURING COMP AN Y • 2222 CAMDEN COURT • OAK BROOK, IL 60523 • 630.574.8484
FOR PARTS, CONT ACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620
PAGE 4