ELKAY
WATERSENTRY WATERSENTRY
WATERSENTRY
WATERSENTRY WATERSENTRY
Filter Monitor Installation Instructions
The Elkay WaterSentry filter monitor extends the life of your filter by reliably indicating when the filter should be replaced.
INSTALLATION:
Remove access panels to the internal portion of the cooler and locate the filter mounting head.
Cut a 2 inch section out of the 1/4 inch tubing after the filter head. Position the flow sensor vertically with the flow arrow
pointing up.
Locate the orientation arrow on the flow switch body. Push the inlet side of the switch (tail of arrow) onto the tubing approxi-
mately 5/8 inch. Push the other tube into the outlet of the switch.
SEE FIGURE BELOW FOR OPERATION DETAILS OF THE FITTINGS
SIMPLY PUSH IN
TUBE TO ATT ACH
INSTALL 2 AAA BATTERIES (Not Provided) Remove the top cover of the monitor by pressing in one side while prying apart.
Locate the AAA battery tray and install 2 AAA batteries. (please note battery polarity) USE ALKALINE BATTERIES ONLY.
Plug sensor lead into the monitor lead and mount to an internal shelf. Press the Reset Button.
TUBE IS SECURED
IN POSITION
PUSHING TUBE IN BEFORE
PULLING IT OUT HELPS TO
RELEASE TUBE
PUSH IN COLLET
TO RELEASE TUBE
FLOW SENSOR
TO BE MOUNTED
VERTICALLY WITH
FLOW ARROW
POINTING UP
WATER SUPPLY
DIRECTION OF
WATER FLOW
OPERATION OF THE MONITOR:
When a filter change is due, the monitor will beep when water is flowing. Replace the filter according to the filter installation
instructions. Press the Reset Button.
To test the monitor, operate the valve to allow water to flow and depress the test switch on the face of the monitor. The alarm
will sound if functioning properly.
TIMER JUMPERS
2000 MIN.
5000 MIN.
8000 MIN.
(SHIPPED POSITION)
AAA BATTERY TRAY
92653C (Rev. D - 10/05)