Elkay 4430BF1 Installation Manual

4430BF FOUNT AIN
Owners Manual
Models 4430BF3, 4430BF2 & 4430BF1
Floor Mounted Tri-Level Bottle Filling Tubular Fountain
MODEL
4430BF1L
MODEL
4430BF2UM
MODEL
4430BF3
INSTALLER
4430BF Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELEC­TROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC T O ELECTRICALLY ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
PAGE 1
98646C (Rev. B - 3/11)
4430BF FOUNT AIN
4430BF3
32 1/8"
14 9/16"
371mm
52 1/8"
1324mm
44"
1118mm
3"
76mm
816mm
22 1/8"
562mm
C
HOLES (6 PL)
1/2"
13mm
O
48"
1219mm
B.C.
14"
12"
305mm
O
356mm
O
3"
76mm
3"
76mm
14 9/16"
371mm
57"
1448mm
64"
1626mm
14 9/16"
371mm
19"
483mm
A
1-1/2"
C
19"
483mm
DRAIN
27"
686mm
37"
940mm
FINISHED FLOOR
7 15/16"
201mm
10"
254mm
O
B
B
8"
203mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
PAGE 298646C (Rev. B - 3/11)
4430BF FOUNT AIN
14 9/16"
371mm
52 1/8"
1324mm
57"
1448mm
4430BF2UL
32 1/8"
816mm
22 1/8"
562mm
3"
76mm
HOLES (6 PL)
1/2"
13mm
O
48"
1219mm
B.C.
14"
356mm
12"
305mm
O
O
3"
76mm
HEIGHT
41 9/16"
1056mm
ORIFICE
C
FINISHED FLOOR
19"
483mm
A
C
1-1/2"
DRAIN
19"
483mm
40 5/16"
1023mm
7 15/16"
201mm
27"
686mm
ACTUAL PRODUCT CONFIGURA TION MA Y V ARY BASED ON MODEL ORDERED.
37"
14 9/16"
371mm
940mm
10"
254mm
O
B
PAGE 3
B
8"
203mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
98646C (Rev. B - 3/11)
4430BF FOUNT AIN
4430BF1M
10"
254mm
O
64"
1626mm
29 3/4"
756mm
ORIFICE
HEIGHT
28 7/16"
723mm
22 1/8"
562mm
C
HOLES (6 PL)
1/2"
13mm
19"
483mm
A
FINISHED FLOOR
O
48"
1219mm
B.C.
14"
356mm
12"
305mm
O
C
7 15/16"
1-1/2"
19"
483mm
DRAIN
201mm
O
27"
686mm
33 5/16"
846mm
34 7/16"
875mm
HEIGHT
ORIFICE
14 9/16"
3"
76mm
371mm
44"
1118mm
ACTUAL PRODUCT CONFIGURA TION MA Y V ARY BASED ON MODEL ORDERED.
B
B
8"
203mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
PAGE 498646C (Rev. B - 3/11)
4430BF FOUNT AIN
1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply . (V alve not furnished)
4. Locate and install fountain using 3/8" minimum screws or bolts, (Screws or bolts not furnished).
5. Prior to installing the bottle filler to the center mounting position of fountain, insert drain pipe (Item #10) by positioning the short end of drain pipe through mounting plate of bottle filler. Install bottle filler to fount ain and secure with supplied hardware.
6. Prior to installing the bottle to the arm mount of fountain, insert the drain pipe (Item #1 1) into the arm tunnel and adjust drain to lean to the left side of the arm when facing the button. Install bottle filler to arm being sure drain tube is above mounting plate of filler . Secure filler to fountain with supplied hardware.
7. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler . Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS DAMAGE TO THE O-RINGS MAY RESUL T.
8. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/2" IPS. Contractor to supply waste trap and service stop valve in accordance with local code.
9. Connect water supply and fountain drain. Connect drain waste "T ee" to fountain drain tubes. Connect outlet of "T ee" to drainage system. Water connection and drain must comply with local codes.
10. Turn on water supply and check all connections for leaks. Threaded drain fittings may require thread sealer to create a leak free connection. Apply thread sealer to threaded connection fittings only , not the slip connection fittings.
CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than 20 psig or higher than 105 psig is not covered by warranty .
1 1. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being con nected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor , color , or sediment problems.
TROUBLE SHOOTING AND MAINTENANCE
Actuation of Quick Connect Water Fittings:
Fountain is provided with lead-free connectors which utilize an o-ring water seal. T o remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".
FIG. 2
1/4" O.D. TUBE WATER INLET TO COOLER
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WA TER SUPPLY
BUILDING WATER INLET
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, insert a small straight
FIG. 3
STREAM HEIGHT ADJUSTMENT :
bladed screwdriver through the access hole in the center of the push button and turn the adjustment screw. Clockwise adjustment will raise the stream and counterclockwise adjustment will lower the stream. For best adjustment, the stream should be approximately 1 1/2" above the top of the bubbler . (See Fig. 3)
FIG. 1
NOTE: WA TER FLOW
DIRECTION
SERVICE STOP (NOT FURNISHED)
PAGE 5
98646C (Rev. B - 3/11)
14 & 24
4430BF FOUNT AIN
23
24
2
24
15 & 24
19 & 23
20
13 or 16
11
24
18 & 25
23
24
15
10
12
17
19
26
15
21
4
12
1
4
15
1
15
21
15
24
5
12
3
4
15
23
1
22
15 24
9
20
13 or 16
5
23
13 or 16
6
9
20
22
23
23
PAGE 698646C (Rev. B - 3/11)
6
ITEMIZED P ARTS LIST
ITEM NO. PART NO.
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26
28467C 28955C 40551C 45464C 45832C 45833C 45734C 55996C 66346C 66815C 66816C 98118C 98530C 98532C 98677C 98678C 98679C 98680C 98681C 98682C 98683C 98684C 98685C 98686C P05031 45931C
4430BF FOUNT AIN
DESCRIPTION
Basin Cover - Round Plate Tailpipe Drain Plug 1-1/2" Access Panel Bottom Cover Drain Tube In - Line Strainer Drain Tube Tube - Drain Tube - Drain (Arm Only) Bubbler Assembly Kit - Regulator W/Spring Kit - "O" Rings and Fittings Kit - Gasket Kit - 1.0 GPM Regulator (BF Only) Kit - Nozzle Kit - Aerator Kit - Bottle Filler Trim Kit - Push Button Kit - Plastic Drain Kit - 90° Plastic Drain Kit - 4400 Series Hardware Kit - Bottle Filler Waterway Aerator Outdoor Bottle Filler Drain Plug
FIG. 4
12
15
24
See Fig. 4
8
5
7
8
8
PRINTED IN U.S.A.
FOR PARTS CONT ACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.260.6640
PAGE 7
98646C (Rev. B - 3/11)
4430BF FOUNT AIN
THIS P AGE W AS LEFT INTENTIONALL Y BLANK
PAGE 898646C (Rev. B - 3/11)
Loading...