Elkay 4420BF1LDB Installation Manual

Page 1
4420BFDB FOUNT AIN
Model 4420BFDB
Bi-Level Tubular Bottle Filler Fountain w/Dog Bowl
4420BF1LDB
4420BF2DB
4420BF1UDB
INSTALLER
4420BFDB Fountains are among the easiest to install Fountains on the market today. To assure you install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING THEINSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave these instructions with the Fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT! INSTALLER PLEASE NOTE.
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WA TER LINES IS A COMMON PROCEDURE. THIS GROUNDING MA Y BE IN THE BUILDING OR MA Y OCCUR A WA Y FROM THE BUILDING . THIS GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNT AIN, CREA TING AN ELEC­TROL YSIS WHICH CAUSES A MET ALLIC T ASTE OR AN INCREASE IN THE METAL CONTENT OF THE WA TER. THIS CONDITION IS A VOIDABLE BY USING THE PROPER MA TERIALS AS INDICA TED. ANY DRAIN FITTINGS PROVIDED BY THE INST ALLER SHOULD BE MADE OF PLASTIC T O ELECTRICALLY ISOLA TE THE FOUNT AIN FROM THE BUILDING PLUMBING SYSTEM.
PAGE 1 98645C (Rev. B - 3/11)
Page 2
4420BFDB FOUNT AIN
3"
76mm
4420BF1LDB
10"
254mm
O
57"
1448mm
37"
14 9/16"
371mm
940mm
27"
686mm
C
1/2"
14"
356mm
O
13mm
(2 PL)
(10 PL)
O
29"
737mm
10"
254mm
19"
483mm
A
1-1/2" DR AIN
FINISHED FLOOR
O
26"
660mm
B.C.
12"
305mm
(2 PL)
40 5/16"
1025mm
HEIGHT
42 3/16"
1072mm
ORIFICE
8"
203mm
O
10"
254mm
O
B
B
6 9/16"
167mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
PAGE 298645C (Rev. B - 3/11)
Page 3
4420BFDB FOUNT AIN
3"
76mm
4420BF1UDB
10"
254mm
O
35 3/16"
894mm
HEIGHT
ORIFICE
33 5/16"
847mm
27"
686mm
C
10"
254mm
1/2"
14"
356mm
O
13mm
(10 PL)
O
(2 PL)
29"
737mm
26"
12"
660mm
B.C.
305mm
O
(2 PL)
10"
254mm
14 9/16"
371mm
O
19"
483mm
A
1-1/2" DRAIN
44"
1118mm
64"
1626mm
FINISHED FLOOR
8"
203mm
O
B
B
6 9/16"
167mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
PAGE 3 98645C (Rev. B - 3/11)
Page 4
4420BFDB FOUNT AIN
4420BF2DB
10"
254mm
O
10"
254mm
O
57"
1448mm
37"
14 9/16"
371mm
3"
76mm
940mm
27"
686mm
C
10"
254mm
1/2"
13mm
14"
(10 PL)
356mm
(2 PL)
O
O
29"
737mm
26"
660mm
B.C.
12"
305mm
(2 PL)
O
19"
483mm
A
14 9/16"
371mm
64"
1626mm
3"
76mm
44"
1118mm
1-1/2" DRAIN
FINISHED FLOOR
8"
203mm
O
B
B
6 9/16"
167mm
30"
762mm
LEGEND
A = 3/8" O.D. UNPLA TED COPPER TUBE CONNECT - SHUT OFF V AL VE BY OTHERS
B = ACCESS P ANEL ( 8" X 10" )
C = REMOV ABLE BOTTOM COVER
PAGE 498645C (Rev. B - 3/11)
Page 5
4420BFDB FOUNT AIN
1. This fountain is to be mounted on a smooth, flat, finished surface with adequate support structure. NOTE: Mounting structure must be capable of supporting 300 lb. load on fountain.
2. Refer to rough-in for plumbing.
3. Install shut-off valve on water supply . (V alve not furnished)
4. Locate and install fountain using 3/8" minimum screws or bolts. (Screws or bolts not furnished)
5. Prior to installing the bottle filler to the center mounting position of fountain, insert the drain pipe (Item #15) by positioning the short end of drain pipe through mounting plate of bottle filler. Inst all bottle filler to fountain and secure with supplied hardware.
6. Prior to installing the bottle filler to the arm mount of fountain, insert the drain pipe (Item #14) into the arm tunnel and adjust drain to lean to the left side of the armwhen facing the button. Install bottle filler to arm being sure drain tube is above mounting plate of filler . Install filler to fountain and secure with supplied hardware.
7. Connect water supply and fountain drain. Connect drain waste "T ee" to fountain drain tubes. Connect outlet of "T ee" to drainage system. Water connection and drain must comply with local codes.
8. Turn on water supply and check all connections for leaks. CAUTION: This fountain is rated for inlet water pressure of 20-105 PSI. A pressure reducing regulator should be used if the inlet water
supply exceeds 105 PSI. Any damage caused by reason of connecting this product to supply line pressures lower than 20
9. Water supply 3/8" O.D. unplated copper tube. Waste 1-1/4" IPS. Contractor to supply waste trap and service stop valve in accordance with local code.
10. Connecting lines to be made of unplated copper and should be thoroughly flushed to remove all foreign matter before being con nected to fountain. This fountain is manufactured in such a manner that it does not in any way cause taste, odor , color , or sediment problems.
1 1. Connect fountain to supply line with a shut-off valve and install a 3/8" unplated copper water line between the valve and the cooler . Remove any burrs from outside of water line. Push the tubes straight into the fittings until they reach a positive stop, approximately 3/4" (See Fig. 2). DO NOT SOLDER TUBES INSERTED INTO PLASTIC FITTINGS AS DAMAGE TO THE O-RINGS MAY RESULT.
TROUBLE SHOOTING AND MAINTENANCE
Actuation of Quick Connect Water Fittings:
Fountain is provided with lead-free connectors which utilize an o-ring water seal. T o remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the tubing.(see Fig.2) To insert tubing, push tube straight into fitting until it reaches a positive stop, approximately 3/4".
FIG. 2
FIG. 3
1/4" O.D. TUBE WATER INLET TO COOLER
FIG. 1
3/8" O.D. UNPLATED COPPER TUBE CONNECT COLD WA TER SUPPLY
NOTE: WA TER FLOW
DIRECTION
BUILDING WATER INLET
SERVICE STOP (NOT FURNISHED)
STREAM HEIGHT ADJUSTMENT :
Stream height is factory set at 35 PSI. If supply pressure varies greatly from this, insert a small straight bladed screwdriver through the access hole in the center of the push button and turn the adjustment screw. Clockwise adjustment will raise the stream and counterclockwise adjustment will lower the stream. For best adjustment, the stream should be approximately 1 1/2" above the top of the bubbler . (See Fig. 3)
PAGE 5 98645C (Rev. B - 3/11)
Page 6
27
4420BFDB FOUNT AIN
18 & 28
23 & 27
22 & 29
27
28
28
25
2
28
19 & 28
21
30
19
23
16
4
1
ARM ONL Y 14
FIG. 4
16
28
19
15
19
25
28
4
16
3
1
19 28 17 OR 20
19
20
9
10
1
19
28
5
9
19
26
8
26
6
27
PAGE 698645C (Rev. B - 3/11)
Page 7
ITEMIZED P ARTS LIST
ITEM NO. PART NO.
1 2 3 4 5 6 7 8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
28467C 28955C 40551C 45464C 45832C 45833C 45476C 45724C 45726C 45727C 45926C 55996C 66346C 66816C 66815C 98118C 98530C 98532C 98677C 98678C 98679C 98680C 98681C 98682C 98683C 98684C 98685C 98686C P05031 45931C
4420BFDB FOUNT AIN
DESCRIPTION
Basin Cover - Round Plate Tailpipe Drain Plug 1-1/2" Access Panel Bottom Cover Drain Tube (Not Shown) Tailpipe - 1-1/4" x 10"Lg. Drain Plug 1-1/2" (Dog Bowl) Body - Bubbler (Dog Bowl) Drain Tube - 1-1/2" x 27-1/2" Lg. In - Line Strainer Drain Tube Tube - Drain (Arm Only) Tube - Drain Bubbler Assembly Kit - Regulator W/Spring Kit - "O" Rings and Fittings Kit - Gasket Kit - 1.0 GPM Regulator (BF Only) Kit - Nozzle Kit - Aerator Kit - Bottle Filler Trim Kit - Push Button Kit - Plastic Drain Kit - 90° Plastic Drain Kit - 4400 Series Hardware Kit - Bottle Filler Waterway Aerator Outdoor Bottle Filler Drain Plug
PRINTED IN U.S.A.
See Fig. 4
5
12
27
10
FOR PARTS CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.260.6640
5
PAGE 7 98645C (Rev. B - 3/11)
11
Page 8
4420BFDB FOUNT AIN
THIS P AGE W AS LEFT INTENTIONALL Y BLANK
PAGE 898645C (Rev. B - 3/11)
Loading...