IMPORTANT NOTICE
All wiring should be carried out by a competent person or a qualified electrician and should be fitted to IEE 17th Edition Wiring regulations BS7671:2008.
TECHNICAL HELPLINE
For further help or assistance or information on this or other products in the range please call the Elkay Technical team on 01675 468222.
Please call the Technical helpline before returning any products to your stockist. In the unlikely event that you have to return your product
please ensure you switch the battery off first.
Elkay Electrical, Coleshill, Birmingham, England.
Tel: +44 (0) 1675 468222 www.elkay.co.uk
For further wiring diagrams and more information on our products please visit our website on www. elkay.co.uk
energysense
ene
rgystyle
energyo
utdoor
pushbutton & touchsensor fitting and operating instructions
pushbutton & touchsensor
Step 3 - Attach the unit with the screws to the wall, then clip
on the front fascia plate. The red LED light will now change to a
single flashing light every 3 seconds approximately. You are now
ready to apply the mains power. The light or chosen appliance
will now start. Press and hold the button, the red flashing light
goes off and the blue locator ring will light up around the
push button/touch pad. Your light source or appliance will
now be switched off and ready for operation.
Operation
1. Press the pushbutton/touch pad and the red LED will light
once. Your light source or appliance will now be switched
on. Please note that the pushbutton has an audible click.
2. At any time during the working of the light source or
appliance, the push button/touch pad can be pressed to
reset the timing sequence to the originally set time,
e.g when the timing period is 30 minutes, if pressed 15 minutes
into the sequence, the timer will reset to 30 minutes.
3. To end the timing sequence prematurely, press and hold the
push button/touch pad until the red LED flashes
continuosly indicating the last minute countdown is in
operation. Your light source or appliance will now be
switched off, after one minute.
4. At one minute prior to the end of the timing sequence, the
red LED will begin to flash continuously for the last minute
of operation. The blue locator ring will then illuminate once
the light source or appliance has gone off.
Operation Notes
If the Elkay Timer does not receive power then the unit will put
the unit into sleep mode to conserve the battery. To reactivate
the unit press and hold for a period of 15 seconds approximately,
the red LED should start to flash, release button, the LED changes
to a flash every 3 seconds press and hold again until load switches
off. The unit will attempt to latch on to the mains power 25 times
automatically before going to sleep mode as mentioned above.
Outdoor Installation
Please note only products in the Elkay energy outdoor range are
suitable for use outdoors. Elkay energy outdoor can only be used
in conjunction with the surface mount box supplied. Take the
surface mount box and remove the knock out section. If required
and to ensure IP66 waterproof rating, please use a suitable M20
cable gland and use appropriate sealing washers. Mount the
surface mount box on a secure surface using the mounting pack
supplied. Place screw cover seals over the mounting screws. It is
essential that the correct IP66 rated connections are made to keep
the IP66 rating of the back box. Steel wire armored connections
without seals are not appropriate.
Turn off mains supply before proceeding with installation - Install
as per previous remote installation instructions - Mount unit
onto surface mount box using the fixing screws at all four corners
ensuring even connection with the seal - Place screw hole seals
over left and right screw cavities - Clip on front fascia plate Re-instate mains supply.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
2 mins 5 mins 10 mins 20 mins 40 mins 60 mins 90 mins 120 mins
Diagram 3 - time settings
Please note that the black bar denotes the position of the dip switch.