Master push button and touch timer
Fitting and operating instructions – Two wire (Lin-Lout). For lighting only
Instruction Data | 350A-1 | 360A-1 | 550A-3 | 560A-3
Features
Time Delay: 2min-2hr
Voltage: 240Va.c. 50Hz
Load Rating & Type: 16A for all lighting loads that are LED,
Compact Fluorescent and Fluorescent, Incandescent and
Resistive.
(This Push button and touch timer cannot be used on contactors.
Please use Elkay three wire Master timers
and sensors)
The pushbutton/touch timers are part of the Elkay family of
switches, timers and detectors which save energy and increase
convenience in and around your home, garden or premises.
Usage
The push button/touch timers are general purpose time controls.
Applications for suitable use include lighting and fans with
lighting.The timers can be used independently or as a master unit
when using slave trigger switches. One master product only for
each circuit being switched with additional slave units at other
positions in the circuit.
When used with some low wattage lighting, low voltage
lighting, LED fittings and 2D flouresecents, please ensure
a capacitor of 4 microfarads is fitted at the load across the
switch live and neutral. Only one is required per circuit.
Supplies of suitable Elkay capacitors can be found at your
local stockist (ref PFCC-1).
IMPORTANT Please note that it is essential that the live in and
live out are identified prior to commencing the installation and
steps 1 – 3 are followed precisely. No neutral is required on this
product (See diagram 1). Do not install the switch timer with the
mains power on as this can damage the product.
Do not megger test or insulation resistance test this product.
Remove before testing or test circuit prior to fitting.
Please ensure that when emergency fittings are tested for
3 hr test that battery switch number 4 on the product is
switched off first and switched back on after test.
energysense
ene
rgystyle
energyo
utdoor
Slave & Momentary Fitting
When connecting with slaves use three core cable connecting
the live in, live out and trigger terminals as shown in Diagram 2.
The optional wire to the slaves only applies to the 350A and 550A
push button slave units and is ideal for retrofitting (See diagram 2).
Please note that the trigger terminal is the third terminal.
Momentary or activating switches can also be used and can be
connected to the Live In and the Trigger terminal of the master.
This product requires a 24 hour power supply. The battery inside
the unit recharges when the light source or appliance is switched
OFF. Where the supply may be interrupted or isolated regularly we
must recommend our products from the three wire range.
Your Elkay unit is compatible with a single gang, 25mm deep
British Standard accessory plate. Please ensure that the top and
bottom lugs are removed from metal wall boxes prior to fitting. For
16mm boxes Elkay provide a spacer plate (product code 220A-1)
to take box depth to 25mm.
energysense
ene
rgystyle
energyo
utdoor
LIVE IN
NEUTRAL
LIVE OUT
DIL
switches
1.
2.
3.
4.
Battery
Lux level
adjustment
Diagram 1
Wiring diagram for a single sensor unit.
energysense
ene
rgystyle
energyo
utdoor
pushbutton & touchsensor fitting and operating instructions
pushbutton & touchsensor
continuosly indicating the last minute countdown is in
operation. Your light source or appliance will now be
switched off, after one minute.
4. At one minute prior to the end of the timing sequence, the
red LED will begin to flash continuously for the last minute
of operation. The blue locator ring will then illuminate once
the light source or appliance has gone off.
Operation Notes
If the Elkay Timer does not receive power then the unit will put
the unit into sleep mode to conserve the battery. To reactivate
the unit press and hold for a period of 15 seconds approximately,
the red LED should start to flash, release button, the LED changes
to a flash every 3 seconds press and hold again until load switches
off. The unit will attempt to latch on to the mains power 25 times
*Optional wire for blue indicator
ring on push button slaves only
NEUTRAL
LIVE OUT
DIL
switches
1.
2.
3.
4.
Battery
Lux level
adjustment
Diagram 2
Wiring diagram for a sensor unit with slave.
Diagram 1
Diagram 2
Push Button Master Touch Master
Master
350A-1*
360A-1
550A-3*
560A-3
Slave
350A-3*
360A-3
550A-5*
560A-5
*Optional wire for blue indicator
ring on push button slaves only

UK Head Office, Station Road. Coleshill, Birmingham B46 1HT
Tel: +44 (0) 1675 468 222 Fax: +44 (0) 1675 464 930
www.elkay.co.uk
The Company‘s policy is one of continuous improvement and reserves
the right to change specifi cations at any time without prior notice.
Diagram 3
Please note that the black bar denotes the position of the dip switch
IMPORTANT NOTICE All wiring should be carried out
by a competent person or qualifi ed electrician and be
fi tted to current IEE Edition wiring regulations.
TECHNICAL HELPLINE
For further help or assistance or information on this or other products in the range please call the Elkay Technical team on
01675 468222. Please call the Technical helpline before returning any products to your stockist. In the unlikely event that
you have to return your product please ensure you switch the battery off fi rst.
energysense
ene
rgystyle
energyo
utdoor
pushbutton & touchsensor fitting and operating instructions
pushbutton & touchsensor
Step 3 - Attach the unit with the screws to the wall, then clip
on the front fascia plate. The red LED light will now change to a
single flashing light every 3 seconds approximately. You are now
ready to apply the mains power. The light or chosen appliance
will now start. Press and hold the button, the red flashing light
goes off and the blue locator ring will light up around the
push button/touch pad. Your light source or appliance will
now be switched off and ready for operation.
Operation
1. Press the pushbutton/touch pad and the red LED will light
once. Your light source or appliance will now be switched
on. Please note that the pushbutton has an audible click.
2. At any time during the working of the light source or
appliance, the push button/touch pad can be pressed to
reset the timing sequence to the originally set time,
e.g when the timing period is 30 minutes, if pressed 15 minutes
into the sequence, the timer will reset to 30 minutes.
3. To end the timing sequence prematurely, press and hold the
push button/touch pad until the red LED flashes
continuosly indicating the last minute countdown is in
operation. Your light source or appliance will now be
switched off, after one minute.
4. At one minute prior to the end of the timing sequence, the
red LED will begin to flash continuously for the last minute
of operation. The blue locator ring will then illuminate once
the light source or appliance has gone off.
Operation Notes
If the Elkay Timer does not receive power then the unit will put
the unit into sleep mode to conserve the battery. To reactivate
the unit press and hold for a period of 15 seconds approximately,
the red LED should start to flash, release button, the LED changes
to a flash every 3 seconds press and hold again until load switches
off. The unit will attempt to latch on to the mains power 25 times
automatically before going to sleep mode as mentioned above.
Outdoor Installation
Please note only products in the Elkay energy outdoor range are
suitable for use outdoors. Elkay energy outdoor can only be used
in conjunction with the surface mount box supplied. Take the
surface mount box and remove the knock out section. If required
and to ensure IP66 waterproof rating, please use a suitable M20
cable gland and use appropriate sealing washers. Mount the
surface mount box on a secure surface using the mounting pack
supplied. Place screw cover seals over the mounting screws. It is
essential that the correct IP66 rated connections are made to keep
the IP66 rating of the back box. Steel wire armored connections
without seals are not appropriate.
Turn off mains supply before proceeding with installation - Install
as per previous remote installation instructions - Mount unit
onto surface mount box using the fixing screws at all four corners
ensuring even connection with the seal - Place screw hole seals
over left and right screw cavities - Clip on front fascia plate -
Re-instate mains supply.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
4.
3.
2.
1.
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
ON DIP
2 mins 5 mins 10 mins 20 mins 40 mins 60 mins 90 mins 120 mins
Diagram 3 - time settings
Please note that the black bar denotes the position of the dip switch.
*Optional wire for blue indicator
ring on push button slaves only
LIVE IN
NEUTRAL
LIVE OUT
DIL
switches
1.
2.
3.
4.
Battery
Lux level
adjustment
Diagram 2
Wiring diagram for a sensor unit with slave.
Installation Steps
DO NOT APPLY MAINS UNTIL INSTRUCTED!
Step 1 - Ensure that the mains power to the circuit is switched
off. Place the previously identifi ed Live In into the terminal marked
L In and the switched Live Out into the L Out terminal.
Step 2 - Switch the battery (switch 4) – you will notice a red LED
light fl ashing on the front of the unit- which will be fl ashing rapidly.
Whilst this is in action please select the desired timings by
selecting the appropriate time settings shown in diagram 3.
Step 3 - Attach the unit with the screws to the wall, then clip
on the front fascia plate. The red LED light will now change to a
single fl ashing light every 3 seconds approximately. You are now
ready to apply the mains power. The light or chosen appliance
will now start. Press and hold the button, the red fl ashing light
goes off and the blue locator ring will light up around the push
button/touch pad. Your light source or appliance will now be
switched off and ready for operation.
Operation
1. Press the pushbutton/touch pad and the red LED will light
once. Your light source or appliance will now be switched on.
Please note that the pushbutton has an audible click.
2. At any time during the working of the light source or appliance,
the push button/touch pad can be pressed to reset the timing
sequence to the originally set time, e.g when the timing period is
30 minutes, if pressed 15 minutes into the sequence, the timer
will restart to 30 minutes.
3. At one minute prior to the end of the timing sequence, the
red LED will begin to fl ash continuously for the last minute of
operation. The blue locator ring will then illuminate once the light
source or appliance has gone off.
4. To end the timing sequence prematurely, press and hold the
push button/touch pad until the red LED fl ashes continuosly
indicating the last minute countdown is in operation. Your light
source or appliance will be switched off after one minute.
Standby/Sleep Mode
If the Elkay Timer does not receive power then the unit will put
the unit into sleep mode to conserve the battery. The unit will
attempt to latch on to the mains power 25 times automatically
before going to sleep mode as mentioned above . To manually
reactivate the unit press and hold for a period of 15 seconds
approximately, the red LED should start to fl ash rapidly, release
button, the LED changes to a fl ash every 3 seconds, press and
hold again until load switches off. Leave in OFF condition for at
least 30 minutes before re-pressing.
Outdoor Installation (550A and 560A only)
Please note only products in the Elkay energy outdoor range
are suitable for use outdoors. Elkay energy outdoor can only
be used in conjunction with the surface mount box supplied.
Take the surface mount box and remove knockouts as required.
Ideally remove with a hole-saw for cleanest effect and remove
any burrs. Drill a small 3mm drain hole at the back of the box
in the position marked‘ DRAIN‘. Drill outwards from the inside
of the box. If required and to ensure IP66 waterproof rating,
please use a suitable M20 cable gland and use appropriate
sealing washers. Two yellow sealing washers are added for
your convenience. Mount the surface mount box on a secure
surface using the mounting pack supplied. Place screw cover
seals over the mounting screws. It is essential that the correct
IP66 rated connections are made to keep the IP66 rating of the
back box. Steel wire armored connections without seals are not
appropriate.
Turn off mains supply before proceeding with installation - Install
as per Installation Steps in these instructions. Mount unit onto
surface mount box using the fi xing screws at all four corners
ensuring even connection with the seal - Place screw hole seals
over left and right screw cavities - Clip on front fascia plate - Reinstate mains supply.
Emergency Light Fittings
When carrying out the 3hr annual Emergency test please ensure
that during the test that this timer is switched off at number 4 for
the duration of the test.
This intelligent timer can detect failed Emergency fi ttings or
ballasts and may go into Standby Mode. If this occurs remove
the faulty emergency fi tting and follow the Standby/Sleep Mode
notes above.