ELK M1TWI Specsheet

OPERA TION
A listen-in session can be initiated two ways. A. By an alarm from a zone that has the "two way
listen-in" option enabled. After the alarm has transmitted, the dialer will hold the line for up to 60 seconds, allowing the CS Operator to press the DTMF "Dual tone multi frequency" command *55* to initiate listen-in. If this tone command is not received, the dialer will hang-up and release the phone line.
B. Via the telephone remote control feature, if enabled. Call the control and wait for it to answer. Then enter a valid passcode. Select option 7 “Audio Monitor” and follow the Tone Commands below. Telephone remote control is enabled from Installer Programming, Menu 07 ­Global System Definitions, Option G01.
NOTE: An active two way session will terminate automatically after 3 minutes, unless manually extended using DTMF tone command 7.
DTMF TONE COMMAND
DTMF *55* BEGIN LISTEN-IN - For use by the
Central Station to initiate listen-in.
Two Way Listen-in
Interface
ELK-M1TWI
APPLICATION:
The ELK-M1TWI Interface allows microphones to be connected to the ELK-M1 for two way voice verfication and listen-in. It features 3 separate microphone zones with up to 4 microphones per zone. Programming options and operation pro­cedures are already built into the M1 control.
Two Way Listen-in
Interface
DTMF 1 TALK - Mutes all microphones and
turns Output 1 speakers ON.
DTMF 2 LISTEN - Turns Output 1 speakers
OFF permitting premises listen-in.
DTMF 3 MAX. SENSITIVITY - Raises the gain
on microphone sensitivity.
DTMF 4 MICROPHONE SELECT -
40 Selects ALL microphones 41 Selects Microphone Zn 1 42 Selects Microphone Zn 2 43 Selects Microphone Zn 3
NOTE: All 3 mic zones are initially active when listen-in begins.
DTMF 5 - [future use] DTMF6 LOW SENSITIVITY - Lowers the gain
on microphone gain to minimum
sensitivity. DTMF 7 EXTEND - Restart 3 minute listen-in. DTMF 8 TERMINATE FOR NOW - Ends the
listen-in session but allows callback
restart within 1 to 60 seconds
(programmable). Control will answer
on first ring during this time. DTMF 99 TERMINATE SESSION - Ends the
listen-in session. DTMF 0 - [future use] DTMF * CANCEL last key-press (undo ) DTMF # - [future use]
Operation of the two way listen-in feature is affected by the following installer programming options:
- Menu 05-Zone Definitions, Option 06 "Enable Listen-
in" must be enabled "Yes" for any triggering zone(s).
- Menu 07-Global System Definitions:
Option G31 "2 Way Listen-in" must be enabled "Yes". Option G32 "2 Way Callback Time" is a timer value which may be set to allow time for the CS to callback and initiate a listen-in session after dialer hangup. Option G01 "TelRmtCtl" must be enabled "Yes" if you wish to initiate listen-in by Telephone Remote Control.
0112706
FEATURES:
Interfaces Listen-in Microphones to the M1
Powers Microphones and Performs Switching
Provides 3 Separate Microphone Zones
Each Zone Can Have Up to 4 Microphones
All Programming and Operation Is Performed
from the M1 Control
SPECIFICATIONS:
Requires ELK-M1TWM or M1TWS Microphones
Operating Voltage: 12 Volts D.C.
M1TWI Board Current Draw: 10mA
Microphone Current Draw. 5mA each
Housing Dimensions: 4.375" x 3.0" x 1.125"
Circuit Board Dimensions: 3.5" x 2.75
NOTE: Use of Two W ay Listen-in may be regulated local or state law and/or ordinance. It is the responsibility of the Installer to check before using this feature.
828-397-4200 Voice
828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Instructions Printed On Inside
INSTALLATION
The following equipment is required: ELK-M1TWI Interface, 8 Conductor J7 Cable (packed with M1TWI), 12 Conductor J16 Cable (packed with M1), and at least 1 M1TWS Speaker/Microphone or M1TWM Microphone.
1. Mount the M1TWI in the M1 enclosure near the right side of the main board. The 12" audio/power cable must reach connector
J7, located about 1/3 up from the lower right side of the M1 board. The M1TWI can be mounted using double sided tape or screws. An alternate method is to remove the board from the black case and mount it on a set of ELK-SWG Glides (not included) which holds the board vertically and conserves space.
2. Install at least one Microphone/Speaker (M1TWS) near the center of the building. Recommended wire is 22 to 24 gauge UTP
(unshielded twisted pair) for the microphone, and 18 to 20 gauge for the speaker.
3. Connect the first microphone to the two terminals marked Zn 1. The M1TWI has 3 microphone zones (inputs) and 3 triggers.
During a listen-in session the operator can choose to listen to ALL zones or select a specific zone. See operation instruc­tions. Each zone is capable of handling up to 4 microphones.
4. Connect the microphone Zn 1 trigger terminal T1 to Output 7 (Tan wire) on the M1 J16 connector. Plug the J16 cable into the
M1. NOTE: Outputs 7, 8, and 9 automatically become assigned as the triggers for Microphone zones 1, 2, and
3 whenever the "Two Way Listen-in" option is enabled in the M1 Installer Programming. See Menu 07-Global System Definitions, option 31.
5. Connect speaker wires directly to Output 1 on the M1. NOTE: The maximum number of speakers is based on the
total load (resistance/impedence). Output 1 should never be loaded below 2 Ohms total load. Typically that allows up to four 8 Ohm speakers to be paralleled.
6. Connect the Aud, +, and - terminals to the Brown/White, White/Blue, and Blue/White wires of the 8 conductor J7 Cable. Plug
the J7 cable into the M1 connector marked J7 "Audio Network Interface". The M1TWI is now powered up and ready to test.
+
-
16 15 14 13 12 11 10
9 8 7
J1
Outputs 7 & 8 are passed through to
these terminals when connected to
Output Relay Board
8 Form C Relays
If an M1RB is already connected to J16 then use
these connections for Mic triggers.
LED
LED
LED
J-16 on M1 Control.
SPDT
Relay
SPDT
Relay
SPDT
Relay
M1RB
M1 Control
(Right Side Terminals)
J16
+12V NEG 16 15 14 13 12 11 10
9 8 7
OUT3OUT2
+
-
+
-
OUT1
J7
AUDIO NETWO RK INTERFACE
OUT3 LED
N/CCOMN/O
OUT 11
From +12V
DC Aux.
N/O COM N/C N/O COM
OUT 9 OUT 10
N/O COM N/C
8
Out
Neg
7
Out
T1
J16 Outputs 7 - 16
+12V switched positive
rated at 40mA. ea.
+VAUX NEG
OUT 16 OUT 15
OUT 14 OUT 13 OUT 12 OUT 11 OUT 10 OUT 9 OUT 8 OUT 7
N/C
COM
N/O
+
Siren
-
+
Voice
-
Audio Network Connection (J7)
For Two-Way Listen-in and Future Use!
Red
+12V
Black
NEG
White Green Brown Blue Orange Yellow Violet
Relay (OUT 3)
2 Parallel Speakers
IMPORTANT NOTE:
Use of Two Way Listen-in may be regulated
local or state law and/or ordinance. It is
the responsibility of the Installer to check
before using this feature.
ELK-M1TWI
Two Way Listen-in Interf ace
Microphone Zones
Zn 1 T1
Zn 2 T2 Zn 3 T3
Mic 4
Mic 4
Mic 4
Mic 3
Mic 3
T3
T2
Not
Used
Grey Pink Tan
Mic 2
Mic 1
Max. 4 mics
per microphone
zone
Zn 1 T1 Zn 2 T2 Zn 3 T3 Aud - +
Mic 2
Mic 1
Mic 3 Mic 2
Mic 1
Aud
+
-
From M1 - J16
B l
u
/
W h
t
Audio/Power from M1 - J7
Connector
Brown/White White/Blue Blue/White
Mic. Triggers
Connector
Out 9 (Grey) Out 8 (Pink) Out 7 (Tan)
W
B r
h
n
t
/
/
W
Bl
h
u
t
Insulate unused
wires.
Plug 8 conductor
B
r
n
/
W
h
t
cord into J7
ZN1 - ELK-M1TWS
Mic/Speaker
White & Black = Speaker
Green (s) = Microphone
ZN2 - ELK-M1TWS
Mic/Speaker
White & Bl ac k = Speak er
Green (s) = Microphone
ZN3 - ELK-M1TWM
Microphone
(2 Green Wires)
W
B
l
h
u
t
/
/
W
B
l
h
u
t
Hookup Diagram for ELK-TWI Listen-in with 2 Mic/Speaker Zones and 1 Microphone only Zone
Loading...