THIS DEVICE COMPLIES WITH PAR T 15 OF THE FCC RULES. OPERA TION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS
DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING
INTERFERENCE THA T MAY CAUSE UNDESIRED OPERA TION.
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT . SUCH MODIFICA TIONS COULD VOID THE USER’S AUTHORITY TO OPERA TE THE EQUIPMENT .
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the
manufacturer’s instructions, may cause Interference to radio and television reception. It has been type tested. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
* If using an indoor antenna, have a quality outdoor antenna installed.
* Reorient the receiving antenna until interference is induced or eliminated.
* Move the receiver away from the security control.
* Move the antenna leads away from any wire runs to the security control
* Have the device or controller plugged into a different outlet so that it and the receiver are on different branch circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user or
installer may find a booklet titled “Interference Handbook” prepared by the Federal Communications Commission helpful: This booklet is
available from the U.S. Government Printing Office, Washington, DC 20402. The user shall not make any changes or modifications to
the equipment unless authorized by the Installation Instructions or Users Manual. Unauthorized changes or modifications could void the
user’s authority to operate the equipment.
List of Available Devices
Part #DescriptionFCC ID Number
FCC STA TEMENT :
106057ElkGuard Wireless Alarm System - “Local Only” No CommunicatorFCC ID: O2K-106058
106058ElkGuard Wireless Alarm System with Cellular “GSM” CommunicatorFCC ID: O2K-106058
Includes: Cellular “GSM/GPRS” Radio Modem Transmitter ModuleFCC ID: MIVGSM0108
106064Wireless Mini Door & Window Switch Transmitter (RR1)FCC ID: O2K-106064
106065Wireless Universal Transmitter w/ext input & Vib analyser (RR2)FCC ID: O2K-106065
106068Wireless 4 Button Keyfob Transmitter (RK4)FCC ID: O2K-106068
106053Wireless 3 Button Keyfob Transmitter (RK3)FCC ID: O2K-MK304
106050Wireless 1 Button Bracelet / Neckless Panic Transmitter (RK1)FCC ID: O2K-106050
106054Wireless Emergency Button Transmitter (RPB)FCC ID: O2K-106054
106056Wireless Door Bell Button Transmitter (RDB)FCC ID: O2K-106056
106051Wireless PIR with Pet Immunity (R15PET)FCC ID: O2K-106051
106062Wireless PIR - Non Pet Immune (R15)FCC ID: O2K-SPIR304
106066Wireless Radio Keypad (RKP)FCC ID: O2K-106066
106060Swivel Mounting Bracket for Wireless PIRN/A
Start Up ............................................................................................................................... 7
Version Number.........................................................................................................................................7
User Modes......................................................................................................................... 7
AC Mode as Primary ............................................................................................................................... 11
Battery Mode as Primary ........................................................................................................................ 11
How can ElkGuard operate so long on battery power only? .............................................................. 11
How is the Battery Mode operating time affected by alarms and daily activity? .............................. 11
Battery Load T est .................................................................................................................................... 12
ElkGuard is a fully self contained security system. It features an on-board motion sensor, loud siren, and
wireless receiver for remote sensors and Arm/Disarm keyfobs. There are several power options, including “AC
Power” primary and “Battery Only” modes. In the “Battery Only” mode ElkGuard is capable of operating for up
to 3 months between recharges, depending upon activity and communication options selected. The ability to
operate for long periods of time without AC power set s ElkGuard apart from its competitors and means less
maintenance for the customer. ElkGuard is manufactured to world class st andards using the latest surface
mount technology and state of the art in-circuit probe testers, together with strict process controls and
adherence to an ISO9001 Quality Assurance Program, ensuring a quality product and a long service life.
ElkGuard is available with our without a Cellular GSM radio communicator. The GSM radio allows ElkGuard to
communicate to a central monitoring station wirelessly , making it totally independent of landline phones. This
feature alone affords ElkGuard with unprecedented ease of installation and portability .
Complete control of the ElkGuard is available from waterproof remote wireless keyfobs, which provides the user
with separate on and off buttons plus a panic button.
ElkGuard not only visually reports all events to the user via its large, bright alphanumeric display , it actually
speaks to the user to report events and advises on the action to take.
ElkGuard contains the latest microprocessor technology ensuring the highest level of security and
dependability . The wireless keyfobs utilize proprietary encryption algorithms to remove the risk of code
duplication by would be intruders though the use of “Code Grabbers.” Detection devices such as wireless
passive infrared detectors and wireless reed switches also offer a high level of security through the use of
programmable supervision techniques and constant monitoring of their battery condition.
ElkGuard also helps resolve the growing issue of manpower and experience when it comes to installation. A
basic install can be completed in minutes using only a screwdriver to mount the equipment. Minimal
programming is required allowing a comprehensive system to be installed in under one hour .
Features
•Built In Passive Infrared (PIR) Motion Detector
•Built In Wireless Receiver for sensors and keyfobs
•Up to 23 supervised and encrypted wireless devices inclusive of 1 keyfob min.
•6 Character alphanumeric display
•Capable of operating on battery for 3 months or longer between recharges (in Battery Only mode)
•Available with or without Cellular GSM Alarm Communicator
•Voice Annunciation (status, events, user instructions)
•Multiple arming modes (ARMED, ST A Y, ST A Y2)
•Adjustment volume of system sounds and voice annunciation
•Optional Strobe Light with alarm memory
•Optional External Speaker for Siren
•Memory and Visual indication of Last Alarm Event
•Non-Volatile Program Memory
Specifications
•Dimensions (H x W x D): 20.5 x 4.5 x 3.3 Inches
•Operating Voltage: 12Vdc
•St andby Battery: 12V 3.3 Ah
•Weight: 5.75 lbs (including battery)
•Plug-in Power Pack/Charger: 18VAC 400mA Class 2 T ransformer
Select a mounting location for the ElkGuard in a main area of the building or home with consideration of the
following recommendations:
1) ElkGuard needs to be high enough in the corner of the room for the motion detector to cover the most
space possible. The ideal mounting height is at least 70" from the floor to the bottom of the unit.
2) The Cellular GSM Radio version of ElkGuard requires access to a nearby GSM transmission tower. It
cannot function without adequate signal strength. Some buildings or locations may not be conducive to
GSM coverage OR the location within the building may so critical that the location of ElkGuard will need to
be adjusted to obtain the best possible signal strength.
3) Even though ElkGuard is capable of operating on battery for 3 between recharges (in Battery Only mode),
connection to an AC electrical outlet (if available) is cert ainly a good practice as it would eliminate the need
to remember to periodically recharge the unit manually .
The design of the ElkGuard makes it ideal for mounting in the corner of a room or to any flat surface. A dif ferent
set of mounting holes are used when mounting the unit in a corner versus a flat surface as illustrated in Figure 3
on the following page.
T o access the mounting holes first remove the speaker grill by holding the main unit and pulling the speaker
grill away from the main cover at the top using the opening tab as shown below .
Next, remove the display face plate by holding the main unit and pulling the face plate away from the main unit
using the opening tabs located on each side of the face plate as shown below .
After removing the speaker grill and faceplate, position the unit on the wall vertically level where it will be
mounted and mark the appropriate mounting holes. This will indicate where to drill the holes for the anchors.
Use a 3/8" drill bit.
Squeeze the anchor tabs down and press the anchor into the hole. The anchors will fit tight so try not to bend
the anchor. Repeat for all of the holes you drilled.
faceplate.
When all the mounting anchors are in place, insert the screws through the mounting holes and into the
anchors. Do not overtighten the screws. Anchors can be stripped out if screws are over tightened.
Snap the speaker grill and display face plate back into place.
After mounting the unit, plug in the AC transformer for 24 hours. This will ensure the onboard battery is fully
T o power up ElkGuard insert one of the two round barrel keys into the lock on the bottom edge of the unit. T urn
the key clockwise 1/4 turn and the unit will momentarily display its V ersion Number , follwed shortly thereafter
by “Learn”. If the unit was previously in any state other than disarmed, this mode will time out in 30 seconds.
During this time the triggers for the main motion detector are ignored. Af ter the time has expired the unit will
resume the mode quietly (without usual arming sounds).
Version Number
Upon initial power up the display will show the current firmware version of the unit. The first production units
began at version 1.0. Please note that any modifications or additional features as a result of a firmware version
change will be highlighted or noted within this manual..
User Modes
ElkGuard has four different modes, DISARMED, ARMED, ST A Y, and STAY2. This allows the user to set
different levels of security when they are home or away . It is very easy to scroll through the available armed
modes by pressing Arm/Lock key on the keyfob multiple times. To disarm simply press the Disarm/Unlock
key on the keyfob. The chart below suggests the type of sensor definition that should be used for specific
protection areas and also illustrates in which Arm Mode the sensor definitions will be active.
INT -This is for interior sensors that are intended to be ACTIVE with the System in the ARMED mode but NOT
ACTIVE in the STAY or STAY2 modes. Typically used for PIR motion sensors.
NTINT - This i s for specific Interior Sensors that are to be Active with the system in the ARMED and STAY modes
but NOT ACTIVE in the STAY2 mode. Typically this should only be used for sensors in unoccupied
areas (high security areas) because they will be Active in the STAY mode and a false alarm could occur
if someone accidentally crossed into the area.
PERIM - This is for Perimeter Sensors (doors and windows) that are to be Active always when the system is in
the ARMED, STAY, and STAY2 modes.
CHIME - This is currently usable for NON ALARM Sensors and is only active when the ElkGuard is in a
DISARMED state.
ICHIME,NCHIIME, PCHIME - As shown below, these 3 Sensor definitions provide various reactions depending
LEGENDA = Alarm - In the Arm Modes shown the Sensor will activate an alarm if tripped.
C = Chime - Sensor will only cause a single chime tone to sound if tripped.
S * = Special Alert - Sensor will cause 5 Special Alert Tones to sound if tripped.
blank = Inactive - Sensor is inactive and cannot create an alarm or sound the chime.
NOTE: ElkGuard will not permit arming to the ST AY or STA Y2 modes if no sensors are defined
as INT or NTINT. Refer to the programming section of this manual for more information.
Page 8
Device Allocation
ElkGuard can have up to 24 devices learned into the system (this is inclusive of the main PIR detector that is
built into the main unit.) This provides up to 23 remote wireless devices like keyfobs, door/window sensors,
and motion detectors. ElkGuard will accept any combination of motion detectors, sensors, and keys, however
you must always have at least one keyfob programmed.
Device Categories
Main Motion Detector
The ElkGuard features a PIR motion sensor integrated into the main unit. This sensor is permanently allocated
as SENSOR 1. Depending on the ElkGuard operating mode and the programming attributes the PIR on the
main unit can be locked out (or excluded from the system). NOTE: When “Locked Out” the Main PIR is
incapable of sensing or reacting to movement.
PROGRAM mode, PULSE or RANGE options selectedNo Lockout
PIR configured as EXCLUD in any operating mode.Full Lockout
DISARM mode and PIR not configured as CHIME.Locked out for 4 minutes
All other modesLocked out for 5 seconds
Wireless Keys
Wireless Keys are considered any type of wireless device that the user operates by a button. There are
several different types of keys. The chart below outlines the different types of keys, the programming options
available for each type, and if the device is supervised by the main unit.
Key T ypeDescriptionProgram OptionsSupervision
User Keyfob3 Button Pendant KeyfobKEY, DURESS, NO P ANNot Supervised
Medical Transmitter Pendant Medical ButtonMEDICNot Supervised
Panic TransmitterSingle Panic ButtonKEY (Panic), DURESSSelectable
DoorbellSingle Button DoorbellBELLNot Supervised
For more information on the programming options listed in the chart above please refer to the Programming
section of this manual.
Sensors
Detector Ty peDescriptionSupervision
Motion DetectorsPIR Motion SensorsSelectable
Reed SwitchDoor and Windows ContactsSelectable
For information on the programming options available for the detectors listed in the chart above, please refer to
the Programming section of this manual.
Activation of the intruder alarm will cause the internal siren to sound for the programmed time. An optional
external speaker may also be wired to ElkGuard for additional sound. Also, an optional strobe light may be
wired to ElkGuard for visual indication of events. The strobe light can flash for 1 hour if the unit is powered only
by the battery , or for 12 hours if the unit is connected to the AC transformer power . Refer to the section titled:
Optional Auxiliary Connections for more information.
Pressing the Disarm/Unlock button immediately after an alarm will disarm ElkGuard. For the next 5 minutes
the display will indicate the source of the alarm, and the time at which the alarm occurred.
Note: ElkGuard features a 6 character display . When displaying messages with more than 6
&
characters the message will scroll across the display in segments. In this manual messages that
contain more than 6 characters are shown with a (<) sign to indicate the separate segments.
DisplayDescription
ALARM< SENSOR<1
ALARM< SENSOR< 2-22
T AMPER< SIREN < BOX
T AMPER< SENSOR < 2-23
P ANIC < KEY < 1-23P ANIC ALARM from a learned keyfob, fixed panic or medical key. When
MEDIC < KEY < 1-23PANIC ALARM from a medical key. The display will show “PRESS < OFF
RADIO < JAMMEDRadio jamming signal detected. If a radio signal is detected in the
ALARM was set off by the main motion detector
ALARM from a learned device such as a reed switch, wireless motion
detectors, etc.
Siren Tamper If used in ARMED mode the unit will sound a full alarm
and report to central station when applicable. Used in ST A Y, ST AY2, or
DISARMED mode the unit will sound a low volume warning sound &
report. The warning will sound again if tripped again. Otherwise, Siren
T amper Exclude will be displayed and the unit will beep. Arming and
Disarming the system will clear the display .
Sensor has reported a tamper alarm. If the unit is in ARMED mode it will
sound a full alarm & report. In ST A Y, ST AY2 and DISARMED modes the
unit will sound a low volume warning sound. T amper deactivation will
cause an alarm restore and re-arm for subsequent T amper activations.
Event log will clear after ARM/DISARM cycle.
the alarm is silenced the display will show which key activated the alarm.
< TO < CANCEL < MEDIC < ALARM” for several minutes. When the
system is disarmed the display will show which key caused the alarm.
operating bandwidth of the ElkGuard the unit will go into ALARM mode if
enabled.
RADIO < T AMPERRadio message that is not an original message has been received. (If
1. A code that is a retransmitted code of an original message has been
received to try to defeat the system.
2. 20 multiple messages have been received by the system to crack
the encryption. Arming/Disarming the system will reset the count.
Page 10
System T roubles
System troubles are not indicated in ARMED, STA Y, or ST A Y2 modes. If DISARMED or upon DISARMING any
existing trouble condition will be displayed along with a time stamp. The message will be displayed by the unit
for 5 minutes.
Note: ElkGuard has a 6 character display. When displaying messages with more than 6
&
characters the message will scroll across the display in segments. In this manual messages that
contain more than 6 characters are shown with a (<) sign to indicate the separate segments.
DisplayDescription
BA TTRY < KEY
(or P ANIC or BELL)
BA TTRY < SENSOR < 2-22
FAIL < SENSOR < 1-22
OPEN < SENSOR < 2-22
LOW < MAIN < BA TTRY
FAUL T < MAIN < BA TTRY
DIALER < RADIO < FAILElkGuard failed to communicate with the Radio GSM Communicator .
Low Battery from the device (keyfob, Panic, etc.). Low battery is in the
device and needs to be changed.
Low Battery in the detector. Low battery is in the device and needs to be
changed
Only works with supervised devices. A radio message has not been
received in supervised number of hours. The device needs to be checked
to ensure it is working properly .
Reed Switch is open on ARMING. The reed switch programmed for Check
mode operation is un-secure when entering ARMED, STAY, or STA Y2
modes. The device should be checked to see if it is secure. A warning
tone will sound at the end of EXIT DELA Y when ARMED.
The main battery in the ElkGuard is low. This condition is cleared when AC
power goes from off to on or when the battery passes a load test.
The main battery in the ElkGuard failed a load test immediately after being
charged. This alarm can only be cleared by switching the master switch
off then on.
Audible Panic alarms (including siren and optional strobe light) may be activated by pressing the special panic
button on the 3 or 4 button keyfobs if they have been programmed as “KEY”. Audible Panic alarms may also
be activated by pressing the single button on the emergency transmitter, provided the emergency transmitter is
programmed as “KEY”.
A silent Duress alarm (without any siren or strobe activation) can be activated by pressing the special panic
button on the 3 or 4 button keyfobs if they have been programmed as “DURESS”. The system will also be
armed or disarmed at the same time. A silent Duress alarm may also be activated by pressing the single
button on the emergency transmitter, provide the emergency transmitter has been programmed as “DURESS”.
Silent Duress means that the system will arm or disarm while a silent Duress alarm is being sent to the central
station.
It is the responsibility of the installer to program ElkGuard to operate in one of several power selection modes.
The primary modes are: 1) AC Mode - ElkGuard operates on AC power (from plug-in charger) with the built-in
standby battery taking over for brief power outages. OR 2) Battery Mode - ElkGuard operates solely on
Battery power (this will require an occasional connection of the plug-in AC charger to recharge the battery).
AC Mode as Primary
In this mode ElkGuard expects to have a full time connection to AC power . It will constantly trickle charge the
internal battery to keep it ready for standby operation. Under the following conditions ElkGuard will switch to a
higher voltage “fast charge” method to quickly bring the battery back to full charge.
• On initial connection to AC or af ter a momentary AC outage ElkGuard will switch to fast charge for 24 hrs.
• When ElkGuard detects its main battery as being low it will switch to fast charge for 24 hours.
• Every 30 days ElkGuard will switch to fast charge for 12 hours
• Following any event that causes the Siren to sound ElkGuard will switch to fast charge for 12 hours.
Exception: If a FAULT<MAIN<BATTER Y is detected, ElkGuard will limit charging of the main battery to 6
hours. This is to help prevent overcharging a battery which has become weak or is near its end or life.
NOTE: Replace the internal battery after 3 to 5 years of use. A definite indication that the battery should be
replaced is when ElkGuard displays a low battery condition while it is connected to AC power . That means
that the battery is no longer able to accept a charge and that it has exceeded its useful life.
Battery Mode as Primary
When configured to this mode (the factory default) and with no full time connection to AC power , ElkGuard’s
internal battery is designed to provide up to 3 months of operation before it must be recharged. The actual
amount of battery time is affected by ElkGuards’ activity; i.e. alarms, armings, disarmings, etc.
Whenever ElkGuard displays “Low Main Battry” it indicates that it is time to connect the unit to its AC power
charger in order to recharge the battery . Plug the AC power charger into a 1 10V AC outlet and plug the charging
connector into ElkGuard for at least 24 hours.
How can ElkGuard operate so long on battery power only?
When ElkGuard is programmed to the Battery Power Only (BA TT) or AC Off mode, it utilizes a proprietary
“hibernation” mode in which it keeps all but the most essential electronics shut down. Alarms, arms/disarms,
and select other signals will wake the unit up to full power operation, and stay that way until activity ceases.
How is the Battery Mode operating time affected by alarms and daily activity?
* Alarm Activations - Each alarm activation reduces the battery operation time by approx. 2 weeks.
i.e. Af ter two (2) alarms the battery operating time would be reduced by 1 full month.
* Arming/Disarming - Each arm/disarm cycle reduces the battery operation time by approx. 2 days.
i.e. Arming/disarming ElkGuard daily would reduce the operating time by half, from 3 mths to 1 1/2 mths.
IMPORTANT: Be certain that ElkGuard is programmed to the factory default Battery
&
Power “BATT” mode (AC Off mode) if it will not be connected to a full time AC power
connection. Otherwise ElkGuard will not hibernate and will consequently only
operate for approximately 24 to 48 hours on its battery when AC poweris not present.
ElkGuard will automatically perform a battery load test:
•Upon power up of the main unit
•Every 24 hours
•Upon disarming
•3 hours after the completion of a recharge cycle (only at the end of a recharge cycle and no siren was
activated after the recharge cycle.)
IMPORTANT: Each time ElkGuard is connected to its AC power charger it initiates a 24 hr
&
“fast charge” using a higher voltage charge cycle. It then drops back to a maintenance or
“trickle” charge at the end of 24 hrs. For this reason, we do not recommend frequent or
repeated unplugging and plugging of the ElkGuard unit to its AC power charger unless: A) It
displays a Low Main Battery message. OR B) Unless it has been operated on battery only
for a substantial period of time. Repeated unplugging and plugging of the AC power charger
without sufficient time for the battery to be depleted can eventually damage the battery due
to the higher voltage “fast charging”.
Nonvolatile Memory
ElkGuard uses EEPROM memory , which is designed to be retained in the event the unit is turned of f or resets
due to abnormal conditions. Data stored in nonvolatile memory includes: All programmed devices and options
associated with the device (keys and detectors). The arm state of the system when the problem occurred to
allow the state to be restored after a power cycle or reset.
System Feedback
Shown below is the audible and visual feedback from the system when armed in the various user arming modes.
ModeInternal Siren
ARMED
STAY
STAY2
DISARMED
Display
ARMED
STAY
STAY2
DISARMED
Say "Armed" if V-ARM is enabled. 1
chirp at end of exit delay.
Say "Armed - Stay" if V-ARM is
enabled. 1 chirp at end of exit delay.
Say "Armed - Stay2" if V-ARM is
enabled. 1 chirp at end of exit delay.
Say "Disarmed" if V-ARM is enabled.
There must always be at least one keyfob programmed into the system. The unit is shipped with 2 keyfobs
which are already programmed into the system.
Entering Programming Mode
Programming mode may be accessed in two different ways:
Method 1Alternate Method 2
Turn the system on by using the
master on/off key switch.
ElkGuard will briefly display its
firmware version number and will then
flash “LEARN” for 10 seconds.
If the system is already on and disarmed, the programming
mode can be accessed by doing the following:
1. Press and hold down the right button on the main unit.
2. Once “ElkGrd” is displayed, continue to hold the right
button while pressing the Disarm/Unlock key on a
programmed keyfob.
3. The unit should go into programming mode
showing “Key 1”.
Exiting from Programming Mode
Once all programming changes are complete there are two (2) ways to exit programming mode.
1) Navigate forwards to the last program option labeled ”P-EXIT” and then press the Arm/Lock key on a pro-
grammed keyfob. In is also possible backup or navigate backwards while in programming mode. See Program
Mode Navigation below.
2) You may also exit programming mode by power cycling the unit with the master on/off key switch.
NOTE: The ElkGuard will automatically exit programming mode after 10 minutes of inactivity .
Programming Mode Navigation and Selection
When navigating through the programming menus devices and system options are displayed steady . The
current programmed value for each device/option is displayed flashing.
• The DISARM/UNLOCK button on the keyfob is used to advance forward through the program menus.
• The ARM/LOCK button on the keyfob is used to select and advance into a displayed menu. The current
value of that menu option will be displayed in a flashing mode. Repeated presses of the Arm/Lock button
will then scroll through the various values or options for that particular menu.
• The PANIC buttton on the keyfob is used to pick or store the value currently being displayed. The new
value will then flash indicating that it is now the programmed value for that option.
• On the Main unit there are two pushbuttons. While in the programming mode the left most
button can be used to navigate backwards though the program menus. This is handy to go backwards,
particularly if you are trying to get to the P-EXIT (program exit) menu or if you just accidentally step forward
past a menu that you wished to program.
Learning a new wireless device requires the Master On/Off key . Proceed with the following:
Step 1 Enter programming mode using Method 1. The display will show the version # and flash LEARN for 10
seconds. NOTE: If unit is ever completely defaulted (erased), it will display “LEARN KEY 1” until at
least 1 keyfob has been programmed. This can be done by simply activating the Learn Procedure
with the keyfob that you want to be Key 1.
Step 2 Press the Arm/Lock button on any existing programmed keyfob to advance the display to “READY”.
This now indicates that the unit is waiting for a wireless transmission from the new device.
Step 3 Proceed to the device to be learned and perform the Learn Procedure (see chart below) while the
display is showing Ready . After a LEARN message is received from a new device it will be added to
the next available empty slot. It is not possible to specify the slot number.
The chart below outlines the Learn Procedure for specific devices:
DeviceLearn Procedure
Keyfob, Doorbell, or Emerg. ButtonHold the panic button down for approx. 8 seconds
PIR, Reed Switch Dr/Wnd SensorsDisconnect battery in device for 10 seconds, then reconnect.
&
Once the device is learned into the system, it will automatically be set to the default definition for that type of
device. Sensor devices default to INT , but can be changed to NTINT or PERIM by pressing the arm/lock
button. Key devices default to KEY, but can be changed to MEDIC, DURESS, etc. by pressing the arm/lock
button. When the desired mode is selected press the Panic button to save the new mode selection. The new
mode will flash indicating the programming change has been stored into memory . To learn another device
simply press the Disarm/Unlock button to go back to the main menu at “LEARN”.
OPTIONAL: Reed Switch devices (door/window sensors) may be learned as a “checked” item. If
the sensor is not closed when the system is armed it will announce and display the sensor
number. In order for a sensor to become learned as a “checked” item it must be in the secure or
closed position (non violated) when it is learned.
Erasing/Replacing Devices
T o erase a device:
Step 1 Enter programming mode using either Method 1 or 2. When using method 1 you must wait for approx.
10 seconds until the LEARN goes away. Once the unit displays Key 1 you may press the Disarm/
Unlock button to step through to the device to be erased. When the device you wish to remove
appears on the display , press the Arm/Lock button. The current definition for that device will be
displayed flashing. Press the Arm/Lock button until ERASE is displayed, then press the Panic button.
The display will now show LEARN, allowing you to program a new device in that slot. This allows a
faulty device to be replaced while keeping the same slot number.
To replace the old device with a new one at this slot number repeat steps 2 and 3 from the top of this
page. To exit from programming follow the procedure for exiting.
&
The last keyfob cannot be used to erase itself. The only way to erase everything is to default the
ElkGuard. When the unit is defaulted a keyfob will need to be programmed into the system.
Programming Notes
The display will flash FULL if an attempt is made to program a device when there are not additional
programming slots available. Existing programmed devices may be viewed in sequence and erased if desired.
KEYUser Keyfob (Arm, Disarm, and Panic) Panic is Audible. This definition should also be
used for single (1) button Emergency Transmitters when audible Panic is desired.
DURESSUser Keyfob (Arm, Disarm, and Panic) Panic is Silent. “Duress” activation
MEDICUser Keyfob (Arm, Disarm) Panic button activates silent Medical Alarm - no audible
BELLFor single (1) button Doorbell Transmitter . Choice of 3 sounds
NO PANUser Keyfob (Arm, Disarm) Panic button is disabled except in Program mode.
ERASEAllows you to permanently remove a key from the system.
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
SENS 1Main Detector in the System(Default = INT)
DefinitionDescription
I NTSensor will be active in the ARMED (A way) mode but not in the S t ay or S t ay2 modes.
NITESensor will be active in the ARMED and ST A Y2 modes.
PERIMSensor will be active in the ARMED, STAY, or STAY2 modes (All Arm modes).
FIRENOT APPLICABLE -Fire detection devices are not currently available.
CHIMENo Alarm - Sensor only provides a Chime Tone in the Disarmed mode.
ICHIMESensor will Alarm in ARMED (Away) mode.
NCHIMESensor will Alarm in ARMED (Away) mode.
PCHIMESensor will Alarm in ARMED (Away) mode.
ERASEPermits you to permanently remove a sensor from the system. Changing any sensor to
this will effectively ERASE or remove it.
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
SENS 2-23Detector 2-23(Default = INT)
DefinitionDescription
I NTSensor will be active in the ARMED (A way) mode but not in the S t ay or S t ay2 modes.
NITESensor will be active in the ARMED and ST A Y2 modes.
PERIMSensor will be active in the ARMED, STAY, or STAY2 modes (All Arm modes).
FIRENOT APPLICABLE -Fire detection devices are not currently available.
CHIMENo Alarm - Sensor only provides a Chime Tone in the Disarmed mode.
ICHIMESensor will Alarm in ARMED (Away) mode.
NCHIMESensor will Alarm in ARMED (Away) mode.
PCHIMESensor will Alarm in ARMED (Away) mode.
ERASEPermits you to permanently remove a sensor from the system. Changing any sensor to
this will effectively ERASE or remove it.
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
RANGESets the Range of the Main Unit Motion Detector(Default = LOW)
OptionDescription
LOWLow range of 8 meters (26.25 ft)
HIGHHigh range of 14 meters (45.93 ft)
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
PULSESets the Pulse Count on the Main Unit Motion Detector(Default = 3)
OptionDescription
1 PULSNumber of times (1-4) the main unit motion detection beam needs to be crossed
2 PULSbefore an alarm occurs
3 PULS
4 PULS
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
SIGNALSignal Check of detectors, keyfobs, etc.
ElkGuard has the ability to show the signal strength of programmed devices. Af ter the unit receives a signal
from an enrolled device it will display the signal strength and beep the corresponding number of times.
Press the arm/Lock button at “SIGNAL” for the System to be ready to receive a signal from the device.
DisplayDescription
SENDWaiting to receive the signal from the device
SENS 2-23 LEVL 1-9Detector received signal strength at level shown on the display
KEY 1-23 LEVL 1-9Key received signal strength at level shown on the display
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
RADJAMRadio Jamming(Default = OFF)
In the case that the system is receiving a continuous source of Radio Frequency Interference (RFI) it will
generate a chime in modes DISARMED, ST A Y, STA Y2. In ARMED mode it will go into a full alarm.
OptionDescription
O NRadio Jamming Detection Enabled
OFFRadio Jamming Detection Disabled
SILENTDialer report only . (no local siren, display or logging).
Limit of 10 reports ; cleared on arming.
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
RADSUBRadio Message Substitution(Default = OFF)
Radio Message substitution refers to any radio signal that is not an original message from a valid ElkGuard
device. This may be an original code that has been retransmitted in an attempt to defeat the system or a
message transmitted multiple times to attempt to crack the encryption. In the event an intentional message
substitution is detected, the system can generate a CHIME in DISARMED, STAY or ST AY2 modes. A full
alarm will be activated if the system is ARMED.
OptionDescription
ONEnabled
OFFDisabled
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
A system trouble will occur if a valid supervisory message has not been received from the detector within a
specific period.
Option Description
1, 4, 8,16,24 Supervision alarm will occur if no supervisory message has been received within a set
time period (period = hours)
OFF Supervision alarm disabled
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
LOKOUTDetector Lockout(Default = OFF)
Alarm lockout prevents multiple sirens sounding due to an alarm from the same device. The external siren will
not sound again until the system is disarmed with the Disarm/Unlock button. The internal siren will always
sound unless the lockout option is on and then the internal siren will behave like an external siren.
OptionDescription
ONEnabled
OFFDisabled
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
ENTRYEntry Delay Time(Default = 15)
The amount of time, in seconds, before the ElkGuard goes into Alarm mode once a detector has been
activated. If the system is disarmed during this time the unit will not go into Alarm mode.
OptionDescription
5-30Time in seconds; values in 5 second steps
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
EXITExit Delay Time(Default = 30)
The amount of time, in seconds, before the sensors become active once the Arm/Lock button has been
pressed. Provides time for users to exit from the building. A warning tone is sounded at the end of the time.
OptionDescription
5-60Time in seconds; values in 5 second steps
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
SIRENSiren Reset Time(Default = 5)
The amount of time, in minutes, that the siren or sirens will sound before automatic reset (cut-off) once the unit
goes into actual Alarm.
OptionDescription
1, 2, 3, 4, 5 Reset time in minutes
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
If set to ON, this causes the external siren to chirp on ARM and DISARM, providing audible feedback to the
user. The siren never chirp s when disarming from the S tay or St ay2 modes, even when this option is enabled.
OptionDescription
O NEnabled (External Siren will chirp on ARM and DISARM)
OFFDisabled (External Siren will NOT chirp on ARM and DISARM)
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
V-ARMVoice Annunciation ARM/DISARM(Default =ON)
OptionDescription
O NArmed and disarmed events annunciated
OFFArmed and disarmed events not annunciated
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
V-ALRMV oice Annunciation Alarm(Default =ON)
OptionDescription
OFFAlarm events not annunciated
ONAlarm events annunciated
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
V-BATTVoice Annunciation Low Battery(Default =ON)
OptionDescription
OFFLow Battery events not annunciated
O NLow Battery events annunciated
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
V-FALTVoice Annunciation Fault(Default =ON)
OptionDescription
OFFSystem faults not annunciated
O NSystem faults annunciated
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
V-DEMOFactory use Only!(Default =OFF)
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
ElkGuard can contact the Central Alarm S tation Monitoring S tation wirelessly using it’ s built-in Cellular GSM
Communicator. The following options are available.
»OPENOpen/Close Reports * Leave ON for Cellular reporting *(Default =ON)
Open/close reports are messages sent to the monitoring station each time the system is ARMED and
DISARMED. This includes the ID number of the keyfob/user . This option should NOT be turned OFF as it is
important for maintaining the current system status. NOTE: Additional monthly charges will only be accessed
if the Central Station and customer wish to receive printout or logs showing the event trails. Restores can also
be sent for alarm events when a key Disarm/Off button is subsequently pressed.
OptionDescription
OFFAll disabled
O NOpen/Close reports enabled (sent at end of exit delay)
RESTORAlarm Restores enabled
RES+OCAlarm Restores and Open/Close Reports enabled
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
»LOWBATLow Battery Reporting(Default =MAIN)
OptionDescription
NONENo low battery reporting
MAINReport low main battery
SENSORReport low detector batteries (including Fixed Panic Buttons)
ALLReport low main unit battery and all detector batteries
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
CLIENT Central Station Acct # * Not used for Cellular reporting * (Default =0000)»
Press Arm/Lock button to view the programmed account number .
Press Arm/Lock button to step through the values for the first digit.
Press Panic/Red button to store the digit. The second digit will now flash.
Repeat for remaining digits.
Press Panic/Red button to store the last digit, now the first digit will flash.
Repeat programming procedure to make corrections, or press Unlock/Disarm to return to top menu in
programming.
0000-FFFF Client acct number. Valid digits are 0 to 9, B, C, D, E, F. Hexidecimal A is not allowed.
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
» These programming locations only pertain to the communication/reporting feature.
»PHONE1 Phone Number 1 * Not used for GSM ‘GPRS’ reporting *(Default = - )
Intended for use with ext. telephone POTS dialer. This location may be used in the future.
Press the Arm/Lock button to display the current programmed number in successive 6-digit segment s. Number
can be up to 20 digits. The first 6-digits lock in with the first digit flashing. Pressing the Disarm/Unlock button
will leave these digits unchanged and step to the next location. Pressing the Arm/Lock button will step through
the values available for the 1st digit. Pressing the Panic/Red button when the correct value is displayed locks
in that digit and moves forward to the 2nd digit which will now flash. Repeat for each digit. When done press
the Disarm/Unlock button to leave and step on to the next option.
Valid Characters
-
In 1st digit location indicates the Phone number is disabled
-
In any other digit location it indicates a 3 second pause
0 thru 9
* Disarm/Unlock button advances to next menu - Arm/Lock button selects menu and advances through its options - Panic button stores the desired option.*
Dialed digits 0 thru 9 respec tively
*
DTMF tone produced by the * key on a phone
#
DTMF tone produced by the # key on a phone
»PHONE2 Phone Number 2 * Not used for GSM ‘GPRS’ reporting *(Default = - )
Intended for use with ext. telephone POTS dialer. This location may be used in the future.
»GSM SGG SM Signal Strength
Displays signal strength in a range of 0-9, where 0 indicates no signal and 9 indicates a strong signal.
»ABORTDialer Abort Delay(Default = 0)
An optional delay time to disarm after a false trip before signal will be is transmitted to the Central St ation.
Option
0 - 60
* DISARM/UNLOCK button advances to next menu - Arm/Lock button selec ts m enu and advances through its options - Panic button stores the desired option.*
Time in seconds , programmed and displayed in 5 second increments.
Description
»MEDICMedical Key Abort Delay(Default = 0)
Programmed time a user can abort sending a medical alarm message to the monitoring station.
Option
0 - 60
* DISARM/UNLOCK button advances to next menu - Arm/Lock button selec ts m enu and advances through its options - Panic button stores the desired option.*
Time in seconds , programmed and displayed in 5 second increments.
Description
»T-CALLDialer Test Call(Default = OFF)
Option
OFF
1, 7, 14, 30
* DISARM/UNLOCK button advances to next menu - Arm/Lock button selects menu and advances through its options - Panic button stores the desired option.*
Description
Test calls disabled.
Test call period in day increments shown at left.
»DIALER GSM Mode Selection(Default = GPRS )
Selects the GSM mode. For North American operation the only valid selection is currently GPRS.
OptionDescription
GPRS
RDIAL
GSMCID
GSMSMS
OFF
* DISARM/UNLOCK button advances to next menu - Arm/Lock button selects menu and advances through its options - Panic button stores the desired option.*
Transmits digital data using the GSM network. (Global Packet Radio)
Radio Dialer - Not currently available for North American operation.
Not for North American operation.
Not for North American operation.
Disables the dialer functionality of ElkGuard
» These programming locations only pertain to the communication/reporting feature.
AC PWR or POWER Mode * IMPORTANT * (Default = OFF (“BATT” in V1.2)
&
Selects the expected power operating mode. This was titled “AC PWR” in V er. 1.0 of ElkGuard. In Ver . 1.2 this
has been re-titled “POWER” with some new options available. The default setting is OFF (BA TT), which selects
“Battery Primary” operation. It is NOT RECOMMENDED that this option be changed to ON (AC ON) unless it
is possible to connect ElkGuard to a full time AC power outlet. Please review the option descriptions below.
While in the programming mode, press the Arm/Lock button to view the available options. Press the Panic
button when the correct option is displayed. Press the Disarm/Unlock button to back out and move on to
another programming location. Press the Disarm/Unlock button to leave the option unchanged and move on.
Version Version
1.0 1.2
Option Option
OFF
(no AC)
n/a
n/a
n/a
ON
n/a
n/a
n/a
* DISARM/UNLOCK button advances to next m enu - Arm/Lock button selec ts menu and advances through its options - Panic button stores the desired option.*
BATT
BAT-30
BAT-1H
BAT-2H
AC-ON
SLR-30
SLR-1H
SLR-2H
Battery is used as the primary power. If there is no activity the unit will hibernate at ultra low
power consumption with the GSM radio totally powered off. Upon any alarm, trouble, or
keyfob action the unit will wake up to handle the event. Should anything need to be reported
the GSM radio will be powered up. Once every 24 hours the GSM Radio will be powered up
for 3 minutes to log onto the network and check for any remote signals.
Similar to BATT option except GSM Radio is only powered up every 30 minutes for logging
on and checking of remote signals. This option not available in version 1.0 of ElkGuard.
Similar to BATT option except GSM Radio is only powered up every 1 hour for logging on and
checking of remote signals. This option not available in version 1.0 of ElkGuard.
Similar to BATT option except GSM Radio is only powered up every 2 hours for logging on
and checking of remote signals. This option not available in version 1.0 of ElkGuard.
AC (plug-in transformer) is used as the primary power. ElkGuard and the GSM radio remain
fully powered up, ready to handle any events or receive any remote control commands over
the network. ElkGuard MUST be connected to AC power 24/7 using its plug-in transformer.
The charging circuit will maintain the battery at optimum charge for backup operation during
brief AC power outages. 24 to 48 hours of battery standby time is available in this mode.
* Future * Solar Cell option [Contact Elk for availability] Operation is similar to BATT except
the Solar Cell would be used to trickle charge the battery when there is sufficient sunshine. If
there is no activity the unit will hibernate with the GSM radio totally powered off. Should
anything need to be reported the GSM radio will be powered up. Once every 30 minutes the
GSM Radio will be routinely powered up for 3 minutes to log onto the network and check for
any remote signals.
Same as option SLR-30 except GSM Radio is only powered up every 1 hours for logging on
and checking of remote signals. This option not available in version 1.0 of ElkGuard.
Same as option SLR-30 except GSM Radio is only powered up every 2 hours for logging on
and checking of remote signals. This option not available in version 1.0 of ElkGuard.
(factory default is OFF ("BATT" in Version 1.2)
Description
In the OFF (BA TT) setting it is possible for ElkGuard to operate for up to 3 months on a fully charged
battery. However, operating time cannot be guaranteed as it is affected by operating conditions such
as: repeated arming & disarming, alarms, troubles, and the age and condition of the battery itself.
Below are some examples of how operating conditions affect the battery operating time.
- Alarm Activations - Each alarm activation will reduce the battery operation time by approx. 2 weeks.
EG: Af ter two (2) alarms the battery operating time would be reduced by 1 full month.
- Arming/Disarming - Each arm/disarm cycle will reduce the battery operation time by approx. 2 days.
EG: A daily arm/disarm will reduce the battery operation time by 1/2, from 3 mths to 1 1/2 mths.
REMINDER! ElkGuard must be periodically connected to AC power to recharge its internal battery.
» These programming locations only pertain to the communication/reporting feature.
Verify that the AC PWR (POWER) option is set to the OFF (BATT) mode if ElkGuard it is not going to be
connected to a full time AC power outlet. This will allow the unit to operate on battery for a longer
period of time, up to 3 months, by hibernating with the GSM radio turned off when there is no activity.
If this option is set to ON (AC-ON), the unit will NOT hibernate, and the GSM radio will stay powered
up, requiring considerably more current. The primary reason you might want to keep the GSM radio
powered up is to allow remote commands to be sent and received at any time. However, this results
in the unit only being able to last 24 to 48 hours on battery when the AC fails.
HINT : Even when ElkGuard will be connected to full time AC power it is possible to extend the battery standby
time during unexpected power outages. This can be accomplished by setting the AC PWR [POWER] to OFF
(BA TT), just as you should when AC power is not connected full time. This will keep the unit awake with the
GSM radio powered only while AC power is present. Should the AC power fail the unit will revert to hibernation
just like it would have without AC on the battery primary mode. Just remember that it will not be possible to
send or receive remote commands while the unit is in hibernation.
DEFALTReset to Factory Defaults
Erase devices and/or default options as required.
If ALL or Key is selected, ElkGuard will jump to the st art of Program Mode, displaying LEARN /KEY1.
OptionDescription
ALLErases all programmed devices and defaults all options
OPTIONDefaults all option values
KEYErases all keys
SENSORErases all detectors; defaults SENSOR 1 (units PIR)
* DISARM/UNLOCK button advances to next menu - ARM/LOCK button selects menu and advances through its options - Panic button stores the desired option.*
If you factory default “ALL” the following procedures will be required to initialize the unit before any key
&
learning or programming may be performed.
1. Turn the Master Power Switch “OFF”
2. While Holding Down both buttons on the main unit, turn the master power switch to “ON”
3. “FACTORY” will flash on the display
4. Press “Button 3 / Panic Button” and continue to hold until “1-“is displayed.
5. Press the “OFF” button on the key fob, until “1- *” is displayed.
6. Turn the Master Power Switch “OFF” and then “ON”
7. Display flashes “Learn”
8. Press “Button 1/ OFF” on Key fob until the Key fob is learned, “Key 1” will be displayed.
P-EXITProgram Mode Exit
T o exit from programming mode there are two choices.
1) Navigate to this programming location and then press the Arm/Lock button.
&
It may be helpful to know that the left button of the main unit (just below the display) will permit you to
navigate backwards in the programming mode. This is particularly helpful if you accidentally skip past a
particular location or if you are near the first locations and need to navigate quickly to the end of the
locations.
2) The other choice for exiting the programming mode is to simply turn off (or power cycle) the main unit using
the master key switch. However, be aware that when the unit is powered up there is a 10 second period in
which the unit does nothing but wait to see if you would like to LEARN a new device. Af ter this 10 seconds with
no keyfob or button presses the unit will resume normal operation.
ElkGuard has three optional auxiliary outputs and 1 optional tamper input available from a plug-in connector on the
back of the unit. Packed with the unit is a mating wiring harness that plugs into connector. See instructions below.
Red Wire - +12Volts ‘fused’ (common for the Strobe, Siren speaker, and Aux,) Outputs ***
Black Wire - Strobe or lamp ( open collector switched 0V ) Output. ***
For a 12 VDC strobe light to provide Visual indication during operation. For Arming and Disarming this output is
momentary only. Constant status not provided. For Alarms this output remains constant unttil system is disarmed.
> Connect strobe lamp positive (+) to the RED “Positive” (+) wire, strobe negative (-) to the Black (-) switched wire.
Arming:12 VDC for
Disarming:12 VDC for
Alarm / Panic: 12 VDC when an alarm event occurs. It continues to provide 12 VDC until the system is
disarmed. (This output is not turned off or affected by the “SIREN” reset time)
Duress:No voltage output when a Duress alarm event occurs
Blue Wire - External Speaker Siren ( open collector switched 0V ) Output. ***
For a single 8 Ohm external speaker. Provides an external audible indication for Alarms and system Arming and
Disarming (momentary only).
> Connect 1 speaker wire to the BLUE wire and the other speaker wire to the RED wire.
Arming:External speaker will beep once upon arming.
Disarming:External speaker will beep three times upon disarming.
Disarm after Alarm:If an alarm has occurred the external speaker will beep 5 times when disarmed.
Alarm / Panic:External speaker will sound continuously until the end of the “Siren Reset” time or
Duress:Nothing - External speaker is silent when a Duress alarm occurs
White Wire - Aux. ( open collector switched 0V ) Output. ***
For a relay or external self contained piezo type low current draw siren. Provides a constant output upon an alarm.
> Connect negative (-) of the device to the WHITE wire and the positive (+) of the device to the RED wire.
Alarm / Panic:Output will be continuously on until “Siren Reset” time or system is disarmed.
Duress:Nothing - Output will NOT be on for a Duress alarm.
2 seconds upon arming the system.
4 seconds upon disarming the system
until the system is disarmed.
Warning: Do NOT exceed a combined current draw of 2 Amps. It is not recommended that these optional
outputs be used if
and the amount of time the unit could operate after an alarm would be seriously degraded.
ElkGuard is being installed without a continuous AC power source. The battery backup time
Yellow and Green Wires - Siren Box Tamper Input
Designed to supervise an outdoor siren box. ElkGuard continually monitors this supervised input regardless of the
armed status of the system. It will give audible and visual notification if this input has been violated.
Armed:If tamper is violated in the Armed mode, the internal sounder and ext. siren output will activate until the
“Siren Reset” time expires or until the system is disarmed. The display will scroll “Tamper Siren Box”
Disarmed:If tamper is violated in the disarmed mode the internal sounder will sound for 4 Seconds. The display
will scroll “Tamper Siren Box”
Tamper Fault: If tamper has been violated and cannot be re-secured, the system can still be armed. The tamper will
be automatically bypasssed. Upon disarm the display will scroll “Tamper Siren Box” until it is secure.
Connect the Yellow wires as shown to the siren box tamper switch. (See Diagram) NOTE: The 3.3K Ohm Resistor
must be securely attached to each end of the yellow leads even if the siren box tamper is not utilized.
Yellow & Green Wires
Without Tamper
3.3 K ohm
resistor
3.3 K ohm resistor
Yellow & Green Wires
With Siren Tamper
Normally
Closed
Siren
Tamper
Red Individual Wires (2) - Permanent ‘hidden’ connection point for AC Transformer
There are two single RED wires on the back of the unit with the ends insulated by heat shrink tubing. Internally, these
wires are parallel to the AC Power connector. These wires permit a more permanent installation of ElkGuard by
allowing a 2 conductor cable to be spliced between these wires and the AC Transformer wires. No Polarity required.
Run this 2 conductor wire inside the wall or otherwise hide it from view for a cleaner installation.
Elk Products, Inc. (“Manufacturer”) warrants to the original purchaser (the “Customer”) that the ElkGuard self contained wireless alarm control and its associated component products shall be free from defects in material and
workmanship for a period of one (1) year from the date of manufacture. In addition, in the event said product is found
to be defective during the first 180 days, manufacturer may allow an over the counter exchange, subject to inspection
and approval by one of it’s representatives. Manufacturer’s obligations under this Warranty shall be limited to
repairing or replacing, at its option, free of charge, any product returned to Manufacturer freight prepaid. Manufacturer
shall have no obligation under this Limited Warranty or otherwise if (1) the Product has been damaged by negligence, accident, mishandling, lightning or flood, transients or surges, or other Acts of God, (2) the Product has not
been operated in accordance with its operating instructions, (3) the Product has been altered or repaired by anyone
outside Manufacturer’s authorized facilities (4) adaptations or accessories have been made or attached to the
Product which, in Manufacturer’s sole determination, have adversely affected its performance, safety or reliability.
Products such as Controls and Batteries have their own warranties. After the expiration of this warranty period,
product will be subject to an inspection fee, after which the customer will be notified of the applicable repair charges
prior to commencing any actual repairs.
OBTAINING W ARRANTY
If a Product should malfunction or fail during it’s warranty period, contact Manufacturer or one of its authorized
distributors for a Return Authorization (RA) number. Returned Products must include a complete description of the
problem, along with the RA number clearly marked on outside of the package. Manufacturer will not be responsible
for any unnecessary items included with any returned Product.
THIS WARRANTY IS THE EXCLUSIVE W ARRANTY FOR ANY PRODUCT. MANUFACTURER SPECIFICALL Y DISCLAIMS ANY AND ALL OTHER WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING ANY W ARRANTIES
OF FITNESS FOR A P AR TICULAR PURPOSE OR OF MERCHANT ABILITY. MANUFACTURER SHALL NOT BE LIABLE
IN TORT, INCLUDING NEGLIGENCE OR STRICT LIABILITY, AND SHALL HA VE NO LIABILITY AT ALL FOR INJURY T O
PERSONS OR PROPERTY. MANUFACTURER’S LIABILITY FOR F AILURE T O FULFILL ITS OBLIGATION UNDER THIS
LIMITED WARRANTY OR ANY OTHER LIABILITY IN CONNECTION WITH A PRODUCT SHALL BE LIMITED T O THE
AMOUNT OF THE PURCHASE PRICE RECEIVED BY MANUF ACTURER FOR THE PRODUCT. THE REMEDIES
STA TED IN THIS LIMITED WARRANTY ARE THE CUST OMER’S EXCLUSIVE REMEDIES AGAINST MANUF ACTURER
REGARDING ANY PRODUCT. UNDER NO CIRCUMSTANCES SHALL MANUF ACTURER BE LIABLE FOR ANY
INDIRECT , INCIDENT AL, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING LOST PROFITS AND REVENUES,
INCONVENIENCE OR INTERRUPTIONS IN OPERATIONS, OR ANY OTHER COMMERCIAL OR ECONOMIC LOSSES
OF ANY KIND. THESE LIMIT ATIONS AND DISCLAIMERS ARE NOT MADE BY MANUFACTURER WHERE PROHIBITED
BY LAW . SOME ST A TES PROHIBIT LIMIT A TIONS OF W ARRANTIES AND THE CUSTOMER MA Y HA VE ADDITIONAL
RIGHTS IN THOSE ST A TES.
For more information contact your local Distributor or:
ELK Products, Inc.
PO Box 100
3266 US Hwy. 70 West
Hildebran, NC 28637 USA