* Try these other fine ELK products *
MM443 Magic Module, 4 Input, 4 Output, Programmable
MM447 Automation Controller w/Voice,Caddx Interface
MV480 Recordable Voice Module, 400 Channels
MKHOME1 Home Control Kit for Caddx NX Controls
MK400 Starter Kit, Includes MM443 & MK485
MK485 Programming Kit, MB485, Cables, Software
MK410 X-10
MK420 iButton™ Access Kit w/ MM443, MA100, MA101
MA100
MA101 iButton™ ‘Touchkeys’,10 pcs w/keyring holders
MA290 Proximity / Wiegand Data Interface to MM443
MB485 Data Bus Interface, RS232 to RS485
MC100 Clock / Calendar Module for MM443
ML8 Link Interface to Caddx NX Controls
MT100 Temperature Sensor Module for MM443
MM220 Magic Module, 2 Input, 2 Output, Programmable
1RT Speaker & Stainless Steel Enclosure
150RT Siren & Stainless Steel Enclosure
155RT Voice Siren in Stainless Steel Box
44 Speaker, 30 W,8 Ohm Compact Horn
45 Siren, Compact Horn, 118db
55 Voice Siren, Compact Horn
M120 Siren, Single Tone, 107db, Mini Horn
SP15 Speaker, 15 watt, Small Horn
SP30 Speaker, 30 watt, Horn
SP35 Speaker, 20 watt, Interior
SP40 Speaker, 40 watt, Horn
SS15 Siren, Dual Tone, 110db, Horn
SS30 Siren, Dual Tone, 120db, Horn
SS36 Siren, Dual Tone, 105db, Interior
73 ECHO Speaker, 20 Watt, Interior
74 ECHO Dual Tone Siren, Interior
75 ECHO Voice Siren, Interior
870 ECHO Speaker, Self Amplified
100 High Performance Siren Driver
110 Voice Siren Driver, English & Spanish
120 Recordable Voice Module and Siren
124 Recordable Voice Module, 4 Channels
950 Surge Suppressor, Phone & Power Line
951 Surge Suppressor, Phone - Single Line
955 Surge Suppressor, Phone - Dual Line
912 Compact Relay,12 Vdc, SPDT
912B Heavy Duty Compact Relay,12/24 Vdc, SPDT
924 Sensitive Relay, 12/24 Vdc, DPDT
941 Alarm Output Director
960 Delay Timer Relay, 1 sec. to 60 min.
1240 Battery, Lead Acid, 12v, 5Ah
1270 Battery, Lead Acid, 12v, 8Ah
12100 Battery, Lead Acid, 12v, 12Ah
12170 Battery, Lead Acid, 12v, 18Ah
12250 Battery, Lead Acid, 12v, 25Ah
P112 12 Volts DC, 1 Amp Power Supply w/Enclosure
P124 24 Volts DC, 800mA Power Supply w/Enclosure
P1216 12 Volts DC, 1.5 Amp Power Supply
P412 12 Volts DC, 4 Amp Power Supply
P624 Power Supply & Battery Charger
PD9 Power Distribution Module
965 Low Battery Cutoff and Power Switch
TRG1640 Transformer, 16.5VAC @ 40 VA
TRG2440 Transformer, 24VAC @ 40 VA
129 Computer Sound Card Interface
800 Audio Amplifier, 10 Watts
900-2 “B” Connectors,Unfilled,500 pcs
902-2 “B” Connectors,Gel filled,500 pcs
980 Telephone Line Fault Monitor
998 Warning Alarm System Decals
999 Double Sided Tape
SL1 Strobe Light, 4 colors available
WK1 Wall Mount Kit for SL1 Strobes
For more information contact your local Distributor or:
ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415
http://www.elkproducts.com Email: info@elkproducts.com
05/02
Magic Module Series
®
Transceiver Kit, Programmed MM443
iButton™ ‘Touchkey’ Reader & Interface Pack
Rust Free Sirens / Speakers
Speakers & Sirens
ECHO™ Sirens & Speakers
Siren & Voice Drivers
Surge Suppressors
Relay Modules
Power Products
Accessories
Alarm Output
Director
ELK-941
APPLICATION:
The ELK-941 separates the steady or pulsing
voltage from a
this into
tional jumper configures Relay 2 to pulse in a
temporal-code pattern which meets ANSI Stan-
dard S3.41. The input trigger can be either positive or negative (pull to ground).
Alarm Output
Director
ELK-941
FEATURES
•Separates Steady and Pulsing Voltage From
a Single Alarm Output and Directs This Into
Two (2) Different Relay Outputs.
•Positive or Neg. Low Current Trigger.
•Two (2) SPDT Relay Outputs.
•Ideal For Two (2) Channel Long Range Radio
or Cellular Transmitters.
•Option For Temporal Pulse On Relay 2.
•Low Current Output During Delay Time.
•LED Indication of Relay Status.
SPECIFICATIONS
•Operating Voltage: 12 Volts D.C.
•Input Trigger Voltage: 9 - 14 Volts D.C.
•Input Trigger Current: 15 mA.
•Max. Current: 96mA (both relays on).
•Relay Contact Rating: 7A @ 30Vdc.
•Valid Pulse Width: .1 - 4 sec. (.125-5Hz).
•Size: 4.4" x 3" x 1.15".
•Meets ANSI S3.41Audible Emergency
Evacuation Signals 3-Pulse Pattern.
Features and Specifications subject to change without notice.
PO Box 100 • Hwy. 70W • Hildebran, NC 28637 • USA
Instructions Printed On Inside
single alarm output and directs
two (2) different relay outputs. An op-
828-397-4200 Voice
828-397-4415 Fax
http://www.elkproducts.com
email: info@elkproducts.com
OVERVIEW
The ELK-941 separates the steady and pulsing voltage
from a single alarm output and directs this into two (2)
different relay outputs. Steady and pulsing voltage
logic is available from most controls that provide only a
single alarm output. The relays on the ELK-941 are
activated according to the trigger input, following a 3 to
4 second verification time delay. Relay 1 will activate if
a steady input is verified, or Relay 2 will activate if a
pulsing input is verified.
Optional Jumper Descriptions
J1 RELAY MODE
TEMPORAL: In the TEMPORAL position, Relay 2
will be switched on and off in a 3 pulse pattern
(3 half-second pulses followed by a 1-1/2
second pause) whenever a pulsing input is
detected. This setting has no effect on Relay 1
(it will always be steady).
[+12V] Connect to the positive (+) side of a 12 Volts D.C.
power source. Nominal operating range is 9 to 14
Volts D.C.
- GND]Connect to the negative (-) side of a 12 Volts D.C.
[
power source.
[
TRG] A positive 9 to 14 Volts D.C. input or a neg. (pull to
ground) to this terminal will activate the ELK-941.
The polarity of the trigger voltage must be
selected using jumper J3. The input trigger can
be from a contol panel's single alarm output, or from
another source such as an automation controller/
timer, a simple pushbutton switch, etc.
OUTPUT CONNECTIONS
[-P] "Pre-activation" Output (30mA MAX). This is active
immediately following the application of a trigger
input for 3 to 4 seconds while the ELK-941 verifies
whether the input is steady or pulsing. Upon
determination of steady or pulse, the appropriate relay will activate and this output will
cease. Note: If the trigger input is pulsing, this
output will also pulse.
[N/O ] Relay 1 Normally Open contact. This terminal is
connected with the COM terminal whenever the
relay is ON (activated).
[COM] Relay 1 Common contact. This "pole" or switching
part of the relay is connected to the N/O terminal
when the relay is ON (activated), and to the N/C
terminal when the relay is OFF (at rest).
[N/C] Relay 1 Normally Closed contact. This terminal is
connected with the COM terminal whenever the
relay is OFF (at rest).
[N/O ] Relay 2 Normally Open contact. This terminal is
connected with the COM terminal whenever the
relay is ON (activated).
[COM] Relay 2 Common contact. This "pole" or switching
part of the relay is connected to the N/O terminal
when the relay is ON (activated), and to the N/C
terminal when the relay is OFF (at rest).
[N/C] Relay 2 Normally Closed contact. This terminal is
connected with the COM terminal whenever the
relay is OFF (at rest).
INPUT CONNECTIONS
STEADY: In the STEADY mode, Relay 2 will be
steady (solid) when a pulsing input is detected.
IMPORTANT NOTE: With Jumper J1 in the
STEADY position, the ELK-941 will provide
dual mode latch, whereby if a steady input
activation is followed by a pulsing input or
visa-versa, both relays will activate and stay
on until the trigger input is completely
removed. If the ELK-941 is used to activate a
long range radio or other communications
device, this feature prevents restoral signals
from being transmitted until both conditions are
resolved.
J2 IMMEDIATE OUTPUT
When an input trigger is first applied, the ELK-941
requires a 3 to 4 second verification time delay to
determine if the input is steady or pulsing. If a siren
is connected, it may be desirable to immediately
activate one of the relays during this delay time.
Such uses include closing ring-back, siren test upon
arming, etc. Jumper J2 selects which relay will
activate (if any) during this time. If Relay 1 or 2 is
selected for immediate output, the selected relay will
"follow" the trigger. ie: If the trigger is steady, the
relay will be steady. If the input is pulsing, the relay
will pulse. Once the ELK-941 has verified what type
of input is being applied, the appropriate relay will
then be activated (which may or may not be the same
relay that was selected for immediate output).
RELAY 1: With the jumper in this position Relay 1
will turn on during the verification time delay.
RELAY 2: With the jumper in this position Relay 2
will turn on during the verification time delay.
OFF: With the jumper in this position neither Relay
will turn on during the verification time delay.
Note: The -P terminal can be used to trigger a piezo
or other low current device for audible or visual
needs. If the trigger input is pulsing, this
output will also pulse. The position of jumper
J2 has no effect on the -P terminal.
J3 TRG (Trigger Polarity)
This jumper bar is used to set the proper input trigger
polarity.
+ Set J3 to "+" if the ELK-941 will be triggered by
a positive voltage input.
- Set J3 to "-" if the ELK-941 will be triggered by
a negative (pull to ground).