ELK 941 User Manual

* Try these other fine ELK products *
MM443 Magic Module, 4 Input, 4 Output, Programmable MM447 Automation Controller w/Voice,Caddx Interface MV480 Recordable Voice Module, 400 Channels MKHOME1 Home Control Kit for Caddx NX Controls MK400 Starter Kit, Includes MM443 & MK485 MK485 Programming Kit, MB485, Cables, Software MK410 X-10 MK420 iButton Access Kit w/ MM443, MA100, MA101 MA100 MA101 iButton ‘Touchkeys’,10 pcs w/keyring holders MA290 Proximity / Wiegand Data Interface to MM443 MB485 Data Bus Interface, RS232 to RS485 MC100 Clock / Calendar Module for MM443 ML8 Link Interface to Caddx NX Controls MT100 Temperature Sensor Module for MM443 MM220 Magic Module, 2 Input, 2 Output, Programmable
1RT Speaker & Stainless Steel Enclosure 150RT Siren & Stainless Steel Enclosure 155RT Voice Siren in Stainless Steel Box
44 Speaker, 30 W,8 Ohm Compact Horn 45 Siren, Compact Horn, 118db 55 Voice Siren, Compact Horn M120 Siren, Single Tone, 107db, Mini Horn SP15 Speaker, 15 watt, Small Horn SP30 Speaker, 30 watt, Horn SP35 Speaker, 20 watt, Interior SP40 Speaker, 40 watt, Horn SS15 Siren, Dual Tone, 110db, Horn SS30 Siren, Dual Tone, 120db, Horn SS36 Siren, Dual Tone, 105db, Interior
73 ECHO Speaker, 20 Watt, Interior 74 ECHO Dual Tone Siren, Interior 75 ECHO Voice Siren, Interior 870 ECHO Speaker, Self Amplified
100 High Performance Siren Driver 110 Voice Siren Driver, English & Spanish 120 Recordable Voice Module and Siren 124 Recordable Voice Module, 4 Channels
950 Surge Suppressor, Phone & Power Line 951 Surge Suppressor, Phone - Single Line 955 Surge Suppressor, Phone - Dual Line
912 Compact Relay,12 Vdc, SPDT 912B Heavy Duty Compact Relay,12/24 Vdc, SPDT 924 Sensitive Relay, 12/24 Vdc, DPDT 941 Alarm Output Director 960 Delay Timer Relay, 1 sec. to 60 min.
1240 Battery, Lead Acid, 12v, 5Ah 1270 Battery, Lead Acid, 12v, 8Ah 12100 Battery, Lead Acid, 12v, 12Ah 12170 Battery, Lead Acid, 12v, 18Ah 12250 Battery, Lead Acid, 12v, 25Ah P112 12 Volts DC, 1 Amp Power Supply w/Enclosure P124 24 Volts DC, 800mA Power Supply w/Enclosure P1216 12 Volts DC, 1.5 Amp Power Supply P412 12 Volts DC, 4 Amp Power Supply P624 Power Supply & Battery Charger PD9 Power Distribution Module 965 Low Battery Cutoff and Power Switch TRG1640 Transformer, 16.5VAC @ 40 VA TRG2440 Transformer, 24VAC @ 40 VA
129 Computer Sound Card Interface 800 Audio Amplifier, 10 Watts 900-2 “B” Connectors,Unfilled,500 pcs 902-2 “B” Connectors,Gel filled,500 pcs 980 Telephone Line Fault Monitor 998 Warning Alarm System Decals 999 Double Sided Tape SL1 Strobe Light, 4 colors available WK1 Wall Mount Kit for SL1 Strobes
For more information contact your local Distributor or: ELK PRODUCTS,INC 828-397-4200 FAX 828-397-4415
http://www.elkproducts.com Email: info@elkproducts.com
05/02
Magic Module Series
®
Transceiver Kit, Programmed MM443
iButton ‘Touchkey’ Reader & Interface Pack
Rust Free Sirens / Speakers
Speakers & Sirens
ECHO™ Sirens & Speakers
Siren & Voice Drivers
Surge Suppressors
Relay Modules
Power Products
Accessories
Alarm Output
Director
ELK-941
APPLICATION:
The ELK-941 separates the steady or pulsing voltage from a this into tional jumper configures Relay 2 to pulse in a temporal-code pattern which meets ANSI Stan- dard S3.41. The input trigger can be either posi­tive or negative (pull to ground).
Alarm Output
Director
ELK-941
FEATURES
Separates Steady and Pulsing Voltage From
a Single Alarm Output and Directs This Into Two (2) Different Relay Outputs.
Positive or Neg. Low Current Trigger.
Two (2) SPDT Relay Outputs.
Ideal For Two (2) Channel Long Range Radio
or Cellular Transmitters.
Option For Temporal Pulse On Relay 2.
Low Current Output During Delay Time.
LED Indication of Relay Status.
SPECIFICATIONS
Operating Voltage: 12 Volts D.C.
Input Trigger Voltage: 9 - 14 Volts D.C.
Input Trigger Current: 15 mA.
Max. Current: 96mA (both relays on).
Relay Contact Rating: 7A @ 30Vdc.
Valid Pulse Width: .1 - 4 sec. (.125-5Hz).
Size: 4.4" x 3" x 1.15".
Meets ANSI S3.41Audible Emergency
Evacuation Signals 3-Pulse Pattern.
Features and Specifications subject to change without notice.
PO Box 100 • Hwy. 70W Hildebran, NC 28637 • USA
Instructions Printed On Inside
single alarm output and directs
two (2) different relay outputs. An op-
828-397-4200 Voice 828-397-4415 Fax http://www.elkproducts.com email: info@elkproducts.com
OVERVIEW
The ELK-941 separates the steady and pulsing voltage from a single alarm output and directs this into two (2) different relay outputs. Steady and pulsing voltage logic is available from most controls that provide only a single alarm output. The relays on the ELK-941 are activated according to the trigger input, following a 3 to 4 second verification time delay. Relay 1 will activate if a steady input is verified, or Relay 2 will activate if a pulsing input is verified.
Optional Jumper Descriptions
J1 RELAY MODE TEMPORAL: In the TEMPORAL position, Relay 2
will be switched on and off in a 3 pulse pattern (3 half-second pulses followed by a 1-1/2 second pause) whenever a pulsing input is detected. This setting has no effect on Relay 1 (it will always be steady).
[+12V] Connect to the positive (+) side of a 12 Volts D.C.
power source. Nominal operating range is 9 to 14 Volts D.C.
- GND]Connect to the negative (-) side of a 12 Volts D.C.
[
power source.
[
TRG] A positive 9 to 14 Volts D.C. input or a neg. (pull to
ground) to this terminal will activate the ELK-941. The polarity of the trigger voltage must be selected using jumper J3. The input trigger can
be from a contol panel's single alarm output, or from another source such as an automation controller/ timer, a simple pushbutton switch, etc.
OUTPUT CONNECTIONS
[-P] "Pre-activation" Output (30mA MAX). This is active
immediately following the application of a trigger input for 3 to 4 seconds while the ELK-941 verifies whether the input is steady or pulsing. Upon
determination of steady or pulse, the appro­priate relay will activate and this output will cease. Note: If the trigger input is pulsing, this
output will also pulse.
[N/O ] Relay 1 Normally Open contact. This terminal is
connected with the COM terminal whenever the relay is ON (activated).
[COM] Relay 1 Common contact. This "pole" or switching
part of the relay is connected to the N/O terminal when the relay is ON (activated), and to the N/C terminal when the relay is OFF (at rest).
[N/C] Relay 1 Normally Closed contact. This terminal is
connected with the COM terminal whenever the relay is OFF (at rest).
[N/O ] Relay 2 Normally Open contact. This terminal is
connected with the COM terminal whenever the relay is ON (activated).
[COM] Relay 2 Common contact. This "pole" or switching
part of the relay is connected to the N/O terminal when the relay is ON (activated), and to the N/C terminal when the relay is OFF (at rest).
[N/C] Relay 2 Normally Closed contact. This terminal is
connected with the COM terminal whenever the relay is OFF (at rest).
INPUT CONNECTIONS
STEADY: In the STEADY mode, Relay 2 will be
steady (solid) when a pulsing input is detected. IMPORTANT NOTE: With Jumper J1 in the
STEADY position, the ELK-941 will provide dual mode latch, whereby if a steady input activation is followed by a pulsing input or visa-versa, both relays will activate and stay on until the trigger input is completely removed. If the ELK-941 is used to activate a long range radio or other communications device, this feature prevents restoral signals from being transmitted until both conditions are resolved.
J2 IMMEDIATE OUTPUT When an input trigger is first applied, the ELK-941
requires a 3 to 4 second verification time delay to determine if the input is steady or pulsing. If a siren is connected, it may be desirable to immediately activate one of the relays during this delay time. Such uses include closing ring-back, siren test upon arming, etc. Jumper J2 selects which relay will activate (if any) during this time. If Relay 1 or 2 is selected for immediate output, the selected relay will "follow" the trigger. ie: If the trigger is steady, the relay will be steady. If the input is pulsing, the relay will pulse. Once the ELK-941 has verified what type of input is being applied, the appropriate relay will then be activated (which may or may not be the same relay that was selected for immediate output).
RELAY 1: With the jumper in this position Relay 1
will turn on during the verification time delay.
RELAY 2: With the jumper in this position Relay 2
will turn on during the verification time delay.
OFF: With the jumper in this position neither Relay
will turn on during the verification time delay.
Note: The -P terminal can be used to trigger a piezo
or other low current device for audible or visual needs. If the trigger input is pulsing, this output will also pulse. The position of jumper
J2 has no effect on the -P terminal.
J3 TRG (Trigger Polarity)
This jumper bar is used to set the proper input trigger polarity.
+ Set J3 to "+" if the ELK-941 will be triggered by
a positive voltage input.
- Set J3 to "-" if the ELK-941 will be triggered by
a negative (pull to ground).