Elica EVR636S2, EVL436S2, EVR636BL Installation Manual

Use, Care, and
Installation Guide
Guide
d’utilisation,
d’entretien et
d’installation
Guía de
mantenimiento
Models: EVL430S2
EVL436S2 EVL424SS EVR630S2 EVR636S2 EVR630BL EVR636BL
READ AND SAVE THESE
INSTRUCTIONS
LISEZ CES
INSTRUCTIONS ET
CONSERVEZ-LES
LEA Y CONSERVE
ESTAS INSTRUCCIONES
LIB0139140A
Printed in Mexico
06/18
1
ENGLISH
Contents
Important safety notice................................................................................................................................................................................................. 3
Electrical & installation requirements ................................................................................................................................................................ 4
Before installing the hood ...................................................................................................................................................................................... 4
Product dimensions ....................................................................................................................................................................................................... 4
List of materials................................................................................................................................................................................................................. 5
Parts supplied .............................................................................................................................................................................................................. 5
Parts not supplied ...................................................................................................................................................................................................... 5
Ducting options and examples.................................................................................................................................................................................. 6
Installation ......................................................................................................................................................................................................................... 6
Electrical connection................................................................................................................................................................................................ 8
Complete the installation........................................................................................................................................................................................ 9
Description of the hood................................................................................................................................................................................................. 9
Control.................................................................................................................................................................................................................................. 9
Maintenance ...................................................................................................................................................................................................................... 10
Warranty ........................................................................................................................................................................................................................... 11
APPROVED FOR RESIDENTIAL APPLIANCES FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference.
Safety Warning: Turn o power circuit at service panel and lock out panel, before wiring this appliance. Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit.
2
IMPORTANT SAFETY NOTICE
I
I CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS OR VAPOURS.
I WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the manufacturer.
B. Before servicing or cleaning the unit, switch power o at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
C. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes & standards, including fire-rated construction.
D. Sucient air is needed for proper combustion and exhausting of gases through the flue (Chimney) of fuel burning equipment to prevent back- drafting. Follow the heating equipment manufacturers guideline and safety standards such as those published by the national fire protection association (NFPA), the american society for heating, refrigeration and air conditioning engineers (ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.
I CAUTION
To reduce risk of fire and to properly exhaust air, be sure to duct air outside - do not vent exhaust air into spaces within walls, ceilings, attics, crawl spaces, or garages.
I WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCT WORK.
I WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE. a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when flambeing food (I.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambe’).
c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate for the size of the surface element.
I WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN THE EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING: a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or other metal tray, then turn o the gas burner or the electric element. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be burned. c) DO NOT USE WATER, including wet dishcloths or towels -
a violent steam explosion will result. d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and you already know how to operate it.
2) The fire is small and contained in the area where it started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
e) Ducted fans must always be vented to the outdoor.
a
Based on “Kitchen Fire Safety Tips” published by NFPA.
a
I CAUTION
Automatically Operated Device - To reduce the risk of Injury disconnect from power supply before servicing.
Install this hood in accordance with all requirements specified.
I WARNING
To reduce the risk of fire or electric shock, do not use this hood with any external solid state speed control device.
3
ELECTRICAL & INSTALLATION REQUIREMENTS
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
• To contact a qualified electrical installer.
• To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91-latest edition** and all local codes and ordinances.
• If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
• Do not ground to a gas pipe.
• Check with a qualified electrician if you are not sure range hood is properly grounded.
• Do not have a fuse in the neutral or ground circuit.
IMPORTANT
• Save Installation Instructions for electrical inspector’s use.
• The range hood must be connected with copper wire only.
• The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.
• Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances.
• A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).
BEFORE INSTALLING THE HOOD
1 For the most ecient air flow exhaust, use a straight run
or as few elbows as possible. CAUTION: Vent unit to outside of building, only.
2 At least two people are necessary for installation. 3 Fittings material is provided to secure the hood to most
types of walls/ceilings, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.
4 Do not use flex ducting. 5 COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house. 6 Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.
Copies of the standards listed may be obtained from: * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575
PRODUCT DIMENSIONS
F
G
A
E
B
Models
EVL424SS EVL430S2
EVR630S2 EVR630BL
A 23
B 19
C
C* Max: 42
5
8” (60 cm) 30” (76.2 cm) 36” (91.4 cm)
11
16” (50 cm)
1
8” (107 cm)
EVL436S2 EVR636S2 EVR636BL
Min: 286⁄16” (72 cm)
D
D** Max: 38
3
16” (97 cm)
Min: 286⁄16” (72 cm)
E 6” (15.24 cm)
F 7
G 8
3
16” (18.3 cm)
3
16” (20.8 cm)
* Ductless (Recirculating) version ** Ducted version
4
LIST OF MATERIALS
Removing the packaging.
I CAUTION
Remove carton carefully, Wear gloves to protect against sharp edges.
I WARNING
Remove the protective film covering the product before putting into operation.
Supplied Part Pieces Supplied Part Pieces
Hood assembly and
LED lamps already installed
5x45 mm
5.4x75 mm
3.5x9.5 mm
4x8 mm
Torx 10 adapter
1
2
Duct covers
6
6” round air transition
4
2
8x40 mm
1
2
4
10x60 mm
2
Duct cover bracket
1
Mounting template
1
1
Tools/Materials required
• Level
• Drill
1
4” (3.2 cm), 1⁄8” (3.2 mm), and 1⁄16” (4.8 mm) drill bits
• 1
• Pencil
• Wire stripper or utility knife
• Tape measure or ruler
• Pliers
• Caulking gun and weatherproof caulking compound
• Jigsaw or keyhole saw
• Metal snips
• Screwdrivers:
- Flat-blade
- Phillips
Parts no supplied
Optional accessories and consumable parts
Recirculating Kit KIT02766
Long Chimney
Extension
Long Chimney
Extension Black
KIT # Part
KIT02762
KIT0140998
5
Ducting Options
Closely follow the instructions set out in this manual. All responsability, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this manual, is declined.
Ducting version Ductless (Recirculating)
The hood is equipped with a 6” (15.2 cm) round transition for discharge of fumes to the outside.
Roof Venting Wall Venting
A
B
A. Roof cap B. 6” (15.2 cm) round vent
A. Wall cap B. 6” (15.2 cm) round vent
B
A
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed. Fittings material is provided to secure the hood to most types of walls/ceilings. However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling. Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Recommended installation height:
Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the capturing of cooking odors, grease and smoke.
In cases where it should not be possible to discharge
A
cooking fumes and vapour to the outside. Attach a charcoal filter and
B
the deflector on the duct cover support bracket. Fumes and vapours are recycled through the top grille by means of a duct connected to the transition and the transition mounted on the deflector. For this version only: purchase the Ductless Recirculating Kit. Minimum Duct Size: 6” Round Pipe.
A. Deflector B. 6” (15.2 cm) round vent
I CAUTION
Installation Heights
Hood
models
GAS
cooktops
ELECTRIC
cooktops
There is no maximum mounting height, however, we recom­mend mounting the hood no greater than 36” (91.4 cm) above the cooking surface. For every inch (2.54 cm) above 36” (91.4 cm), fume and moisture capture eciency diminishes at an in­creasing rate and may not deliver an acceptable level of venti­lating performance. This hood is intended for household use.
PLEASE READ THE INSTALLATION MANUAL FOR SPECIFIC APPLICATION. Check your ceiling height and hood height before selecting your hood.
EVL430S2, EVL436S2,
EVL424SS
EVR630S2, EVR636S2, EVR630BL, EVR636BL
27″ (66.6 cm) 30″ (76.2 cm)
24″ (61 cm) 27″ (66.6 cm)
Installation
Prepare location
• It is recommended that the vent system be installed before
hood is installed.
• Before making cutouts, make sure there is proper clearance
within the ceiling or wall for exhaust vent.
• Check your ceiling height and the hood height maximum
before you select your hood.
6
1 Disconnect power. 2 Determine which venting method to use: roof, wall, or
nonvented.
3 Select a flat surface for assembling the range hood.
Place covering over that surface.
I WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING.
4 Using 2 or more people, lift range hood onto covered
surface.
Mounting the duct cover bracket 1 Determine and mark the centerline on the wall where the
canopy hood will be installed. Disconnect power.
2 Select a mounting height from the Installation Heights
chart. Mark a reference line on the wall.
3 Tape template in place, aligning the template centerline
and bottom of template with hood bottom line and with the centerline marked on the wall.
A
Install Range Hood
1 Using 2 or more people, hang range hood on 2 mounting
screws through the mounting slots on back of hood.
A
B
B
A. Centerline B. Fastener locations C. Mounting height reference (hood bottom line)
C
4 Mark centers of the fastener locations through the
template to the wall. IMPORTANT: All screws must be installed into wood. If there is no wood to screw into, additional wall framing supports may be required.
5 Remove the template. 6 Drill
7 Install the 2 - 5 x 45 mm mounting screws. Leave a
3
16” (4.8 mm) pilot holes at all locations where screws
are being installed into wood.
1
4” (6.4 mm) gap between the wall and the back of the screw head to slide range hood into place.
1
4
(6.4 mm)
Vent cover bracket installation 1 Attach vent cover bracket to wall flush to the ceiling using
2 - 5 x 45 mm screws.
A
C
C
A. Mounting screws B. Mounting slots
1
C. Lower mounting screws
2 Mark with a pencil the lower mounting holes location. 3 Uninstall the hood assembly, and drill 3⁄16” (4.8 mm) pilot
holes at marked locations.
4 Hang the range hood again on 2 upper mounting screws. 5 Level the range hood and tighten upper mounting screws. 6 Install 2 - 5 x 45 mm lower mounting screws and tighten.
Use the optional wall anchors if needed.
Connect Vent System 1 Install transition on top of hood (if removed for shipping)
with 2 - 3.5 x 9.5 mm sheet metal screws.
A
B
B
A. 8 x 40 mm anchors B. Centerline on wall
C. Vent cover support bracket D. 5 x 45 mm screws
D
Complete preparation 1 Determine and make all necessary cuts in the wall for the
vent system. Install the vent system before installing the hood. See “Venting Requirements” section.
2 Determine the required height for the home power supply
cable and drill a 1¼” (3.2 cm) hole at this location.
3 Run the home power supply cable according to the
National Electrical Code or CSA Standards and local codes and ordinances. There must be enough ½” conduit and wires from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical terminal box.
NOTE: Do not reconnect power until installation is complete. 4 Use caulk to seal all openings.
A. Vent transition B. 3.5 x 9.5 mm screw
For vented installations only: 1 Fit vent system over the exhaust outlet. 2 Measure from the bottom of the air deflector to the
bottom of the hood outlet. Cut the ductwork at the measured dimension.
Roof outlet
Wall outlet
Dimension to measure
3 Seal connection with clamps. 4 Check that back draft dampers work properly.
7
Electrical Connection
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
DISCONNECT POWER BEFORE SERVICING. REPLACE ALL PARTS AND PANELS BEFORE OPERATING. FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
1 Disconnect power. 2 Remove terminal box cover. 3 Remove the knockout in the terminal box cover and install
a UL listed or CSA approved
4 Run home power supply cable through strain relief, into
terminal box.
E
D
C
B
A
A. Home power supply cable B. UL listed or CSA approved strain relief C. Black wires
5 Use UL listed wire connectors and connect black wires
(C) together.
6 Use UL listed wire connectors and connect white wires (E)
together.
1
2” strain relief.
D. UL listed wire connectors E. White wires F. Green (or bare) and yellow-green ground wires
Install duct covers
• When using both upper and lower vent covers, push lower cover down onto hood and lift upper cover to ceiling and install with two mounting screws.
NOTE: For vented installations, the upper vent cover may be reversed to hide slots.
C
D
C
A
B
A. Upper vent cover B. Lower vent cover C. 4 x 8 mm screws D. Bracket
NOTE: To prevent scratches, lay paper or a kitchen towel over the edges of the lower flue duct to protect the surface.
I WARNING
ELECTRICAL SHOCK HAZARD.
I WARNING
ELECTRICALLY GROUND BLOWER. CONNECT GROUND WIRE TO GREEN AND YELLOW GROUND WIRE IN TERMINAL BOX. FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK.
7 Connect green (or bare) ground wire from home power
supply to yellow-green ground wire (F) in terminal box using UL listed wire connectors.
8 Tighten strain relief screw. 9 Install terminal box cover. 10 Check that all light bulbs are secure in their sockets. 11 Reconnect power.
8
Complete Installation
• For non-vented (recirculating) installations only, install charcoal filters over metal grease filter. See the “Mainteinance” section.
• Install metal filters. See the “Mainteinance” section.
To get the most ecient use from your new range hood, read the “Maintenance” section. Keep your Use, Care, and installation Guide close to range hood for easy reference.
Description of the Hood
EVR630 & EVR636 models
Control
1 2 3 4 5 6
1. Button ON/OFF motor (stand by)
2. Button for low speed (suction power) selection
When flashing, it indicates that you must wash the grease filter.
3. Button for medium speed (suction power) selection
4. Button for high speed (suction power) selection
5. Button for intensive speed (suction power) selection
It lasts 5 minutes then it returns to medium speed (suction power).
6. Button ON/OFF lighting
Press briefly to switch on or o the lighting of the hood. Press and hold to adjust the intensity of the light.
Indicators of filter saturation:
At regular time intervals, the hood indicates the need of performing filter maintenance.
5
1
2
1. Blower and light controls
2. LED lamps
3. Grease filter handle
4. Grease filter
5. Duct covers
CFM Reduction System
Button
Perform grease filter maintenance.
Button
Perform activated charcoal filter maintenance. NOTE: Filter saturation signal is visible within the first minute after switching off the hood; within this time, the reset of saturation indicators must be performed.
Reset of filter saturation indicators:
Press and hold the button
3
4
Activation of saturation indicator activated charcoal filter: NOTE: This operation must be performed with the hood off.
This indicator is normally deactivated; press and hold the
button steady light.
To deactivate the function, press and hold the button the button lights up flashing.
on with steady light:
flashing:
to activate the function: the button lights up with
,
Before operating your hood:
Some States and Provinces of the US & Canada restrict the maximum exhausting airflow of range hoods. Airflow is measured as cubic feet per minute (CFM). These maximum levels allowed are detailed in the local code of your area. Please check local codes to find out if you need to restrict the maximum airflow of your hood. If your local code mandates a maximum airflow level below the maximum airflow of this hood (i.e. 600 CFM), please execute the procedu­re below to reduce the maximum airflow.
1
5
1 Turn the motor OFF. 2 Press the ON/OFF (1) and Intensive speed (5) buttons
together for 3 seconds. You will hear a beep and all control lights will illuminate for 3 seconds. This action will Disable speeds 3 and 4 and eectively lower the Maximum airflow to > 300 CFM.
3 Locate the CFM certification sticker in the hardware pack. 4 Peel and Ax this sticker to a visible area in the blower.
This sticker provides ocial certification to your local inspector that this hoods maximum airflow has been reduced to > 300 CFM.
9
EVL424SS, EVL430S2 & EVL436S2 models
5
1
2
3
4
1. Blower and light controls
2. LED lamps
3. Grease filter handle
4. Grease filters
5. Duct covers
Maintenance
Cleaning
Do not spray cleaners directly to the control while cleaning the Hood. The cooker hood should be cleaned regularly (at least with the same frequency with which you carry out maintenance of the fat filters) internally and externally. Clean using the cloth dampened with neutral liquid detergent. Do not use abrasive products. Do not use chlorine base cleaners. DO NOT USE ALCOHOL!
I WARNING:
Failure to carry out the basic cleaning recommendations of the cooker hood and replacement of the filters may cause fire risks. Therefore, we recommend oserving these instructions. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
Grease Filter
Traps cooking grease particles. This must be cleaned once a month using non aggressive detergents, either by hand or in the dishwasher, which must be set to a low temperature and a short cycle. When washed in a dishwasher, the grease filter may discolour slightly, but this does not affect its filtering capacity. To remove the grease filter, pull the spring release handle.
EVR630 & EVR636 models EVL424, EVL430 & EVL436 models
A
Control
1. Light On/O button
2. Blower On/O button
3. Blower speed minimum button
4. Blower speed medium button
5. Blower speed maximum button
NOTE: Control buttons will light up when range hood is On.
Operating the light
The Light On/O button (1) controls both lights. Press once for On and again for O.
Operating the blower
The Blower On/O button (2) turns the blower On or O. The Blower Speed buttons (3, 4 and 5) set the desired speed and control the sound level for quiet operation. The speed can be changed anytime during fan operation by pressing the desired blower speed button.
1 To turn the blower On, press the Blower On/O button (2)
and the desired speed button (3, 4 or 5).
2 To turn the blower O, press the Blower On/O button (2).
Any of the 3 blower speed buttons can be in the On position at the same time. The blower will operate at the highest speed button that is pushed in. For lower blower speeds, the higher speed buttons must not be pushed in.
A
A. Spring release handle
Replacing a LED Lamp
The LED lights are replaceable by a service technician only. See “Who to contact” section in the warranty for service contact information.
Charcoal filter NOTE
When used in recirculation mode, To Reduce the Risk of Fire and Shock use only conversion kit Models: Recirculating kit: KIT02766
If the model is not vented to the outside, the air will be recirculated through disposable charcoal filters that help remove smoke and odors.
1 Cover the grill that protects the suction motor with the
carbon filter so that the slots on the filter correspond to the pins on the sides of the motor protection grill.
2 Turn the carbon filter clockwise to block them (bayonet
fixing).
NOTE: The charcoal filters cannot be cleaned. It should be replaced every 4-6 months (depending on hood usage).