Important safety Notice..............................................................................................................................................3
Before installing the hood ....................................................................................................................................................................................4
List of Materials...........................................................................................................................................................5
Parts supplied...................................................................................................................................................................................................... 5
Parts not supplied................................................................................................................................................................................................ 5
Dimensions and Clearances......................................................................................................................................6
Ducting Options and Examples.................................................................................................................................7
Description of the hood & Controls........................................................................................................................13
Replacing the light bulb......................................................................................................................................................................................16
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
INSTALLATION MUST COMPLY WITH ALL LOCAL CODES.
IMPORTANT: Save these Instructions for the Local Electrical Inspector’s use.
INSTALLER: Please leave these Instructions with this unit for the owner.
OWNER: Please retain these instructions for future reference.
Safety Warning: Turn off power circuit at service panel and lock out panel, before wiring this appliance.
Requirement: 120 V AC, 60 Hz. 15 or 20 A Branch Circuit
READ AND SAVE THESE INSTRUCTIONS
Important safety Notice
CAUTION
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
TO EXHAUST HAZARDOUS OR EXPLOSIVE
MATERIALS OR VAPOURS.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
A. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer.
B. Before servicing or cleaning the unit, switch power off at
service panel and lock service panel disconnecting
means to prevent power from being switched on
accidentally. When the service disconnecting means
cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
C. Installation Work and Electrical Wiring Must Be Done By
Qualified Person(s) In Accordance With All Applicable
Codes & Standards, Including Fire-rated Construction.
D. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (Chimney) of fuel
burning equipment to prevent back- drafting. Follow the
heating equipment manufacturers guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), the American Society for
Heating, Refrigeration and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
E. When cutting or drilling into wall or ceiling, do not
damage electrical wiring and other hidden utilities.
F. Ducted systems must always be vented to the outdoors.
CAUTION
To reduce risk of fire and to properly exhaust air, be
sure to duct air outside - do not vent exhaust air into
spaces within walls, ceilings, attics, crawl spaces, or
garages.
WARNING
TO REDUCE THE RISK OF FIRE, USE ONLY METAL
DUCT WORK.
Install this hood in accordance with all requirements
specified.
WARNING
To Reduce The Risk Of Fire Or Electric Shock, Do Not
Use This Hood With Any External Solid State Speed
Control Device.
WARNING
TO REDUCE THE RISK OF A RANGE TOP GREASE
FIRE.
a) Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may
ignite. Heat oils slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
c) Clean ventilating fans frequently. Grease should not be
allowed to accumulate on fan or filter.
d) Use proper pan size. Always use cookware appropriate
for the size of the surface element.
WARNING
TO REDUCE THE RISK OF INJURY TO PERSONS, IN
THE EVENT OF A RANGE TOP GREASE FIRE,
OBSERVE THE FOLLOWING:
a) SMOTHER FLAMES with a close-fitting lid, cookie
sheet, or other metal tray, then turn off the gas burner or
the electric element. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
b) NEVER PICK UP A FLAMING PAN - you may be
burned.
c) DO NOT USE WATER, including wet dishcloths or
towels - a violent steam explosion will result.
d) Use an extinguisher ONLY if:
1) You know you have a class ABC extinguisher, and yo u
already know how to operate it.
2) The fire is small and contained in the area where it
started.
3) The fire department is being called.
4) You can fight the fire with your back to an exit.
OPERATION
a. Always leave safety grills and filters in place. Without
these components, operating blowers could catch onto hair,
fingers and loose clothing.
The manufacturer declines all responsibility in the event of
failure to observe the instructions given here for installation,
maintenance and suitable use of the product. The
manufacturer further declines all responsibility for injury due
to negligence and the warranty of the unit automatically
expires due to improper maintenance.
CAUTION
Automatically Operated Device - To Reduce The Risk Of
Injury Disconnect From Power Supply Before Servicing.
This unit is equipped with integral disconnecting switch
located inside the blower housing.
3
Electrical & Installation requirements
Electrical requirements
IMPORTANT
Observe all governing codes and ordinances.
It is the customer’s responsibility:
To contact a qualified electrical installer.
To assure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA 70
— latest edition*, or CSA Standards C22.1-94, Canadian
Electrical Code, Part 1 and C22.2 No.0-M91 - latest
edition** and all local codes and ordinances.
If codes permit and a separate ground wire is used, it is
recommended that a qualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure range
hood is properly grounded.
Do not have a fuse in the neutral or ground circuit.
IMPORTANT
Save Installation Instructions for electrical inspector’s use.
The range hood must be connected with copper wire only.
The range hood should be connected directly to the fused
disconnect (Or circuit breaker) box through metal electrical
conduit.
Wire sizes must conform to the requirements of the National
Electrical Code ANSI/NFPA 70 — latest edition*, or CSA
Standards C22.1-94, Canadian Electrical Code Part 1 and
C22.2 No. 0-M91 - latest edition** and all local codes and
ordinances.
A U.L.- or C.S.A.-listed conduit connector must be provided
at each end of the power supply conduit (at the range hood
and at the junction box).
Copies of the standards listed may be obtained from:
* National Fire Protection Association Batterymarch Park Quincy,
Massachusetts 02269
** CSA International 8501 East Pleasant Valley Road Cleveland,
Ohio 44131-5575
Before installing the hood
1. For the most efficient air flow exhaust, use a straight run
or as few elbows as possible.
CAUTION: Vent unit to outside of building, only.
2. At least two peopl e are necessary for installation.
3. Fittings material is provided to secure the hood to most
types of walls/ceilings, consult a Qualified Installer,
check if they perfectly fit with your cabinet/wall.
4. Do not use fle x ducting.
5. COLD WEATHER installations should have an additional
backdraft damper installed to minimize backward cold air
flow and a nonmetallic thermal break to minimize
conduction of outside temperatures as part of the
ductwork. The damper should be on the cold air side of
the thermal break.
The break should be as close as possible to where the
ducting enters the heated portion of the house.
6. Make up air: Local b uilding codes may require the use of
Make-Up Air Systems when using Ducted Ventilation
Systems greater than specified CFM of air movement.
The specified CFM varies from locale to locale. Consult
your HVAC professional for specific requirements in your
area.
4
List of Materials
Parts supplied
• Hood Canopy
• Rectangular Metal Transition with Back draft dampers
• Care & Use / Installation Instructions
• Filters
• 4x8 screws x 3 (to assemble Rectangular Metal
Transition)
• 4,5x13 screws x 6
• 5x45 screws x 4
• 8x40 wall anchors x 4
Parts not supplied
• Duct, conduit and all tools required for installation.
• Ductless Recirculating Kit
To be used only in the Ductless (Recirculating)
version
includes: charcoal filter
• 8" Rounded metal transition.
5
Dimensions and Clearances
6
Ducting Options and Examples
Closely follow the instructions set out in this manual.
All responsibility, for any eventual inconveniences, damages or fires caused by not complying with the instructions in this
manual, is declined.
Venting methods
Vent Exhaust Option
The hood is designed for vertical or horizontal
discharge or can be installed in a recirculating
ductless version:
Vertical discharge:
Use a rectangular duct 3 1/4” x 10”.
Horizontal discharge:
Use a rectangular duct 3 1/4” x 10”.
Recirculating (non vented ductless).
NOTE: For ductless (Recirculating) version only: purchase the Ductless Recirculating Kit.
Minimum Duct Size (Ducting/Ductless version): 3-1/4" x 10" Rectangular Pipe.
Preparation
Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be
constructed.
Fittings material is provided to secure the hood to most types of walls/ceilings.
However, a qualified technician must verify suitability of the materials in accordance with the type of wall/ceiling.
Before making cutouts, make sure there is proper clearance within the ceiling or wall for exhaust vent.
Hood installation height above cooktop is the users preference. The lower the hood is above the cooktop, the more efficient the
capturing of cooking odors, grease and smoke.
CAUTION: FOR GAS RANGES INSTALLATION: MOUNT THIS HOOD SO THAT THE BOTTOM EDGE IS AT 30" (76,2 CM)
ABOVE THE COOKING SURFACE.
FOR ELECTRIC RANGES INSTALLATION: MOUNT THIS HOOD SO THAT THE BOTTOM IS NOT LESS THAN 24" (61 CM)
AND NOT MORE THAT 30" (76,2 CM) ABOVE THE COOKING SURFACE.
HOUSEHOLD USE. PLEASE, READ INSTALLATION MANUAL FOR SPECIFIC APPLICATION.
Check your ceiling height and the hood height maximum before you select your hood.
7
Installation
Installation - Ducting version
After having choosen the vent option, proceed as
follows:
Remove the grease filters.
Remove the 2 lateral supports.
Attach exhaust adaptor/damper over knockout
opening with two exhaust adaptor screws. Make
sure damper pivot is nearest to top/back edge of
hood.
Remove tape from damper flap.
NOTE: The exhaust adaptor/damper can be installed
up to 1 inch on either side of the hood center to
accommodate off-center ductwork. In extreme
offcenter
installations, one end of the duct connector
may need to be trimmed to clear the electrical cable
clamp.
Remove the duct knockouts using a flat blade
screwdriver and a small hammer.
Use the screwdriver by knocking out the pannel in
similar fashion to a scalpel.
Take care of sharp edges.
Mark holes
Select the vent option that your installation will require
and proceed to that section:
Outside top exhaust
(Vertical duct– 3 1/4”x 10” Rectangular)
Use the diagram or the hood as a template and mark
the locations on the cabinet for ductwork, electrical
wiring and keyhole screw slots.
• Use the diagram or the hood as a template and mark the
locations on the cabinet for ductwork, electrical wiring and
keyhole screw slots.
Installation to wall
(Horizontal duct– 3 1/4”x 10” Rectangular)
• Use the diagram or the hood as a template and mark
the locations on the wall for ductwork, electrical wiring
and keyhole screw slots.
Slide the hood back against the wall. Tighten the
mounting screws. Be sure the screw heads are in the
narrow neck of the keyhole slot.
Connect Ductwork to hood.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction
box.
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2
wood shims the width of the trim and attach them to
the cabinet bottom recess on both sides.
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4” extra toward
the front of the cabinet so you can move the duct
freely when installing the hood.
It may also ease installation by cutting the hole 10 1/2”
instead of 10”.
Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.
Fix the wiring conduit to the hood.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
Final installation step
Replace
Replace filters.
Check operation of the hood.
9
the 2 lateral supports.
IMPORTANT: If the hood doesn’t switch ON, before
calling for service, check if the internal General ON/
OFF Push button Switch is switched ON.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the “Use and Care Information” section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.
10
Installation - Ductless (Recirculating) version
Attention!
If it is intended to use the hood in the recirculating
version do not remove any duct knockouts and order
the necessaruy charcoal filter from your supplier.
Remove the grease filters.
Remove the 2 lateral supports and the posteior one.
Use the diagram or the hood as a template and mark
the locations on the cabinet for electrical
wiring and keyhole screw slots.
Rotate blower unscrewing the two fixing screws.
Installation to wall
• Use the diagram or the hood as a template
and mark the locations on the wall for electrical wiring
and keyhole screw slots.
For recessed bottom cabinet only
If the cabinets have front, side or back trim, make 2
wood shims the width of the trim and attach them to
the cabinet bottom recess on both sides.
Reinstall the posterior support.
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, cut out 3/4” extra toward
the front of the cabinet so you can move the duct
freely when installing the hood.
It may also ease installation by cutting the hole 10 1/2”
instead of 10”.
11
Drive a mounting screw (from the hardware packet)
partway into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.
Fix the wiring conduit to the hood.
Slide the hood back against the wall. Tighten the
mounting screws. Be sure the screw heads are in the
narrow neck of the keyhole slot.
Connect Ductwork to hood.
Electrical connection
WARNING
Electrical Shock Hazard
Warning: Turn off power circuit at the service panel
JUNCTION BOX WITH 3 WIRES, ONE OF WHICH
(GREEN/YELLOW) SERVES TO GROUND THE
APPLIANCE. TO PROTECT YOU AGAINST
ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE
MUST BE CONNECTED TO THE GROUNDING WIRE
IN YOUR HOME ELECTRICAL SYSTEM, AND IT
MUST UNDER NO CIRCUMSTANCES BE CUT OR
REMOVED.
Failure to do so can result in death or electrical
shock.
Remove the knockout and the Junction box cover and
install the conduit connector (cULus listed) in junction
box.
IMPORTANT: If the hood doesn’t switch ON, before
calling for service, check if the internal General ON/
OFF Push button Switch is switched ON.
If range hood does not operate:
• Check that the circuit breaker is not tripped or the house
fuse blown.
• Disconnect power supply. Check that wiring is correct.
To get the most efficient use from your new range hood,
read the “Use and Care Information” section.
Keep your Installation Instructions and Use and Care
Guide close to range hood for easy reference.
Run 3 wires; black, white and green ,according to the
National Electrical Code and local codes and
ordinances, in 1/2" conduit from service panel to
junction box.
Connect black wire from service panel to black or red in
junction box, white to white and green to green-yellow.
Close and secure junction box cover.
Final installation step
Replace
Replace filters.
Check operation of the hood.
the 2 lateral supports.
12
Description of the hood & Controls
1. Blower and light controls
2. Halogen lamp housings
3. Grease filter Handle
4. Grease filter
13
Controls
Use the high suction speed in cases of concentrated kitchen
vapours. It is recommended that the cooker hood suction is
switched on for 5 minutes prior to cooking and to leave in
operation during cooking and for another 15 minutes
approximately after terminating cooking.
Note: Hood retains last speed setting when aspiration
switch is turned off.
Description of control panel
1. Light Button
• Press lamp button to turn ON the light on High
Intensity (Lamp state previously OFF).
• Press lamp button to turn ON the light on Low
Intensity (Lamp state previously ON).
• Press lamp button to turn OFF the light (Lamp state
previously ON).
2. Timer Button
• The default tim er setting is 10 minutes, and it can be
adjusted between 60 minutes and 1 minute.
• After pressing the timer button, the control enters to a
timer setup mode, and user can adjust the timer
countdown time with the “+” and “-” buttons within 5
seconds. The timer can be initiated immediately
pressing the timer button, after setting the timer
duration or pressing the timer button twice (default 10
minutes setting).
• If no action occurs within 5 seconds, the countdown
will start.
• During the timer setup the “+” and “-” buttons are
dedicated to the timer and no motor action will occur.
• Once the timer is initiated, it can be cancelled by
pressing the timer button again.
3. Display
• Shows the hood settings.
• The display will be l it at low intensity when the hoo d
is not operating.
Pressing any key the display will light up at high
intensity.
• The displa y will be lit at high intensit y when the hood
is operating.
If no key is pressed within a minute the display will
return to being lit at low intensity.
4. “-” Button. Speed Decrease / OFF
• This button is used to decrease the fan speed, or
turn OFF the fan.
• The fan will turn OFF if the “-” button is pressed and
the hood was in the first speed.
• If the fan is at second speed and the “-” button is
pressed, the fan will be set to first speed.
• If the fan is at third speed and the “-” key is pressed,
the fan will be set to second speed.
• If the fan is at fourth speed and the “-” button is
pressed, the fan will be set to third speed.
• If the fan is OFF and the “-” button is pressed, the
control backlight will light up.
5. “+” Button. Speed Increase / ON
• T his button is used to increase the fan speed, or turn
ON the fan.
• The fan will turn ON if the “+” button is pressed and
the hood was OFF.
• If the fan is at first speed and the “+” button is
pressed, the fan will be set to second speed.
• If the fan is at second speed and the “+” button is
pressed, the fan will be set to third speed.
• If the fan is at third speed and the “+” button is
pressed, the fan will be set to fourth speed.
• If the fan is at fourth speed and the “+” button is
pressed, a beep will sound.
Clock programming
• The clock can be reprogrammed at any time except
during an active timed function.
• The clock can be displayed in a twelve hour format and
valid clock times are from 1:00 to 12:59.
• The clock can be reprogrammed pressing the “Timer”
button for 3 seconds, and after, the clock can be
adjusted with the “+” and “-” buttons.
• T he user can have minute increments / decrements of 1
minute, but if the user keep pressing the “+” / ”-” buttons
for more than 1 second, the increments / decrements will
be of 5 minutes.
During this option the control will round to the nearest 5
minutes.
• The user can finish on reprogramming the clock pressing
the “Timer” button.
• After 1 minute of no button pressed the control will
accept the programmed clock time and will add one
minute to the set clock.
Grease filter saturation alarm (Optional)
• After thirty fan functional hours, the display will show
“Grease Filter” if the fan is active.
When this icon is shown in the display, the grease filters
installed are required to be washed.
• To reset the gr ease filter saturation alarm the user must
press the “+” button for 5 seconds, after this action the
icon “Grease filter” is not displayed, and the hood has
the normal display operation.
Charcoal filter saturation alarm (Optional)
• After one hundred and twenty functional hours of the fan,
the display will show “Charcoal Filter” if the fan is
active. When this icon flashes on display, the charcoal
filters installed are required to be replaced or
reactivated.
• To reset the charcoal filter s aturation indication the user
must press the “-” button for 5 seconds, after this time
the icon “Charcoal filter” is not displayed and the hood
has the normal display operation.
Audible signal activation and deactivation
• The audible signals can be activated or deactivated
pressing the “Light” button for 5 seconds.
• If the audible signal is activated, a tone must sound and
the “Snd” symbol must appear on the display for 3
seconds.
• If the audible signal is deactivated, the “Snd” symbol
must appear on the display for 3 seconds and no tone
must sound.
14
Charcoal filter inclusion and exclusion (Recirculating
accessories)
• T he charcoal filter inclusion or exclusion can be set by
pressing the “+” and “-” buttons at the same time for 5
seconds.
• The Inclusion or exclusion of charcoal filter must be
selected while the lamps and the motor are OFF.
• When the charcoal filter has been excluded, the charcoal
filter alarm is disabled.
Heat sensor
• The control is equipped with a heat sensor that will turn
on the blower at third speed if excessive heat occurs
(over 149° F or 65°C) surrounding the control area.
• If the blower is OFF or if it is operating at first speed, the
blower will be set automatically to third speed, the
display shows the word "CArE" to indicate that heat
sensor has detected an excessive heat.
• During this state, the user may raise the blower spe ed to
fourth speed but can not decrease the speed.
• When the temperature level on the hood drops to
normal, the blower will operate in the setting defined by
the user before the alarm occured.
15
Maintenance
ATTENTION! Before performing an y maintenance operation, isolate the hood from th e electrical supply by switching off at the
connector and removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the plug must be removed from the socket.
Cleaning
Do not spray cleaners directly to the control while
cleaning the Hood.The cooker hood should be cleaned
regularly (at least with the same frequency with which you
carry out maintenance of the fat filters) internally and
externally. Clean using the cloth dampened with neutral
liquid detergent. Do not use abrasive products. DO NOT
USE ALCOHOL!
WARNING:
Failure to carry out the basic cleaning recommend ations of
the cooker hood and replacement of the filters may cause
fire risks.
Therefore, we recommend oserving these instructions.
The manufacturer declines all responsibility for any dama ge
to the motor or any fire damage linked to inappropriate
maintenance or failure to observe the above safety
recommendations.
Grease Filter
Traps cooking grease particles.
This must be cleaned once a month using non aggressiv e
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle. When
washed in a dishwasher, the grease filter may discolour
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Replacing the light bulb
CAUTION
Before replacing the lamps, switch power off at service
panel and lock service panel disconnecting means to
prevent power from being switched on accidentally.
NOTE: Turn off the lights and fan. Allow the lights to
before handling. If new lights do not operate be
cool
sure lights are inserted correctly before calling service.
Replace Lights
• Remove the damaged light (twist counter clockwise)
and replace with a new 120 Volt, 50 Watt (maximum)
50° halogen light made for a GU10 base, suitable for
use in open luminarie.
Charcoal Filter
If the model is not vented to the outside, the air will be
recirculated through disposable charcoal filters that help
remove smoke and odors.
The charcoal filters cannot be cleaned.
They must be replaced.
Cover the grill that protects the suction motor with the
carbon filter so that the slots on the filter correspond to the
pins on the sides of the motor protection grill.
Turn the carbon filter clockwise to block them (bayonet
fixing).
The charcoal filters should be replaced every 4-6 months
(depending on hood usage).
NOTE: DO NOT rinse, or put charcoal filters in an automatic
dishwasher.
NOTE: Charcoal filters are not included with the hood.
They must be ordered from your supplier.
Order the needed kit specifying your ho od model and width
size.
16