RE200
Cardioid,True Condenser
Instrument Microphone
• Continuous presence rise
enhances sound quality
• True condenser design
• Transformerless output
• Small, unobstrusive profile
• Includes stand clamp,
windscreen and zippered
vinyl pouch
Descriptions and Applications
The Electro-Voice RE200 is a cardioid, true
condenser instrument microphone designed
for the exacting acoustic reproduction of
choirs, strings, percussion and brass instruments in live performance and sound recordings. The RE200 is designed to be used in
professional remote recordings, sound reinforcement systems, sound studios and motion picture/TV scoring stages.
The RE200's frequency response (see Figure 1) has a continuous presence rise to enhance the sound quality. The excellent transient response and smooth frequency response is gently lifted above 1,000 Hz, lending an open, transparent detail to the recorded
sound.
The RE200's transducer is a true, external
biased condenser element based on the
RE2000 transducer design. (Most studio recording microphones are true condensers
because they have greater sensitivity and stability than an electret element). The diaphragm is ultrathin, gold-laminated, environmentally stabilized and ultralow in mass. The
electrode is a precision-cut single piece, ceramic disc layered with gold. The transducer
is biased by an internal dc-to-dc converter to
ensure that its sensitivity and performance
is not dependent on phantom voltage. The
RE200 transducer is cradled in an
AcoustiDYM™ shock-mount system for mechanical isolation. The RE200's electronics
are designed to operate from 12 Vdc to 52
Vdc phantom power.
The RE200 is small, light and rugged, making it ideal for a variety of applications without being obstrusive.
The RE200 is supplied with the model 311
microphone stand clamp, a zippered vinyl
carrying pouch and a Wind Tech™ 5700-12
black external foam windscreen.
Architects' and Engineers'
Specifications
The microphone shall be an external biased,
condenser type with a frequency response
of 150 to 18,000 Hz. The microphone shall
have a cardioid pattern with a rear response
which is typically 15 dB below the front response at 1.0 kHz. The microphone shall be
phantom powerable with a voltage of 12 V
dc to 52 V dc. The microphone shall have an
output power level of –39 dB, where 0 dB =
1 milliwatt per pascal, and output shall not
be appreciably affected by the following tem-
___________________
1. Wind Tech™ is a trademark of Olsen audio Group, Inc.
The 5700 windscreen can be purchased separately from
Wind Tech™ at 602/998-7140 or (fax) 602/998-7192.
1
perature and humidity extremes: –29 to74
°C (–20 to 165°F) when relative humidity is
0 to 50%; –29 to 57°C (–2- to 135° F) when
relative humidity is 0 to 95%. The microhone
shall have a nominal, balance transformerless
output impedance of 200 ohms. The microphone shall have a semigloss "camera" black
finish.
Dimensions of the body shall be 27.9 mm
(1.1 in.) wide at transducer, 20.3 mm (0.8
in.) wide at handle and 137.2 mm (5.4 in.)
long. The microphone shall have a built-in
connector similar or equivalent to the
Switchcraft A3M.
The Electro-Voice RE200 is specified.
Limited Warranty
Electro-Voice products are guaranteed
against malfunction due to defects in materials or workmanship for a specified period,
as noted in the individual product-line
statement(s) below, or in the individual product data sheet or owner’s manual, beginning
with the date of original purchase. If such
malfunction occurs during the specified period, the product will be repaired or replaced
(at our option) without charge. The product
will be returned to the customer prepaid. Ex-
clusions and Limitations: The Limited
RE200 Cardioid, True Condenser Instrument Microphone
W arranty does not apply to: (a) exterior finish or appearance; (b) certain specific items
described in the individual product-line
statement(s) below, or in the individual product data sheet or owner’s manual; (c) malfunction resulting from use or operation of
the product other than as specified in the
product data sheet or owner’s manual; (d)
malfunction resulting from misuse or abuse
of the product; or (e) malfunction occurring
at any time after repairs have been made to
the product by anyone other than ElectroVoice Service or any of its authorized service representatives. Obtaining Warranty
Service: To obtain warranty service, a customer must deliver the product, prepaid, to
Electro-V oice Service or any of its authorized
service representatives together with proof
of purchase of the product in the form of a
bill of sale or receipted invoice. A list of authorized service representatives is available
from Electro-Voice Service at 600 Cecil
Street, Buchanan, MI 49107 (800/234-6831
or FAX 616/695-4743). Incidental and
Consequential Damages Excluded: Product repair or replacement and return to the
RE200 Cardioid, True Condenser Instrument Microphone
customer are the only remedies provided to
the customer. Electro-Voice shall not be liable for any incidental or consequential damages including, without limitation, injury to
persons or property or loss of use. Some states
do not allow the exclusion or limitation of
incidental or consequential damages so the
above limitation or exclusion may not apply
to you. Other Rights: This warranty gives
you specific legal rights, and you may also
have other rights which vary from state to
state. Electro-Voice Wired Microphones
are guaranteed against malfunction from any
cause for two (2) years from the date of original purchase. In addition, the Limited Warranty for the acoustic system contained in
these microphones shall apply for the life of
the product, defined as a period of ten (10)
years from the date that the manufacture of
the specific microphone has been discontinued. Any and all active electronics incorporated in these microphones are guaranteed
against malfunction due to defects in materials or workmanship for a period of three
(3) years from the date of original purchase.
The Limited Warranty does not extend to
2
cables, cable connectors, or switches. Additional details are included in the Uniform
Limited W arranty statement.
For warranty repair or service information, contact the service repair department
at: 616/695-6831 or 800/685-2606.
For technical assistance, contact Technical
Support at 800/234-6831 or 616/695-6831,
M-F, 8:00 a.m. to 5:00 p.m. Eastern Standard Time.
Specifications subject to change without notice.
Figure 1—Frequency Response
5 dB
Response in dB
20
50 1000500200
30
100 2000
FREQUENCY IN HERTZ
Figure2—RE200 Polar Response
330°
300°
270°
240°
100 Hz
500 Hz
1,000 Hz
5,000 Hz
210°
0°
180°
30°
150°
5000
60°
120°
90°
10000
20000