Electrothermal MH8524, MH8524X1 Instruction Manual

Wax Dispenser
MH8524 & MH8524X1
Instruction Manual
ET0003 / Version 1.0
Introduction
Thank you for purchasing this Electrothermal product. To get the best performance from the equipment, and for your own safety, please read these instructions carefully before use.
1
2
4
3
5
6
1 Wax dispenser 2 Instruction manual 3 Warranty card
4 UK power lead 5 EU power lead 6 US power lead
(MH8524 only) (MH8524 only) (MH8524X1 only)
This equipment is designed to operate under the following conditions:
v For indoor use only v Use in a well ventilated area v Ambient temperature range 5°C to 40°C (41°F to 104°F) v Altitude to 2000 m (6500 ft) v Relative humidity not exceeding 80% (temperature 31ºC) decreasing to 50% (temperature 40ºC) v Mains supply uctuations not exceeding 10% of nominal v Overvoltage category II IEC60364-4-443 v Pollution degree 2 IEC664 v Use with a minimum distance all round of 300 mm (12 in.) from walls or other items
If the equipment is not used in the manner described in this manual and with accessories other than those recommended by the manufacturer, the protection provided may be impaired.
2
General Description
The Wax Dispenser is designed for on-demand delivery of molten wax. The novel design of the instrument ensures that it takes up a minimum bench space in the laboratory, whilst still maintaining a large 7.5L capacity tank, for melting up to 6kg of pelletized wax at a time. The Wax Dispenser has digital temperature control which provides accurate temperature control of the molten wax, and is coupled with an ultra fast heating system for rapid melting of pelletized wax. Delivery of molten wax is via a non-drip lever tap, which is heated via a dedicated heating
system, which prevents blockages resulting from solidied wax and ensures an even ow of wax. The inner tank has a lter screen (0.5mm mesh) tted to prevent coarse particles from blocking the delivery tap. The tank is also fully
insulated to prevent heat loss from the tank and to ensure that the outer surfaces of the tank are safe to touch.
Important Safety Advice
This product is designed for laboratory use only. Always follow good laboratory practice. Users should be aware of the following safety advice:
v DO NOT use without appropriate training. v SHOCK HAZARDS OR UNSAFE PRACTICES ARE DANGEROUS as they can cause severe personal injury, re
or death.
v DO NOT use combustible substances near hot objects. v DO NOT use the equipment in hazardous atmospheres. v DO NOT immerse the equipment in water. v DO NOT operate or handle any part of the product with wet hands or use on surfaces that may become ooded. v NEVER move the product while still connected to the power supply. v HIGH TEMPERATURES ARE DANGEROUS as they can cause serious burns to operators and ignite combustible
material.
v USE CARE AND WEAR PROTECTIVE GLOVES TO PROTECT HANDS. v NEVER lift or carry the instrument during operation. v NEVER use the tap to lift or carry the instrument. v DO NOT position the unit so that it is difcult to disconnect from the mains supply using the mains plug. v The mains outlet socket used should be located close to the equipment and readily identiable and accessible
to users. v DO NOT leave equipment switched on and it is not recommended to leave any heating apparatus unattended during operation.
v The unit should be carried using both hands. v DO NOT allow molten wax to accumulate on the surface of the equipment. v DO NOT use if the equipment is empty v DO NOT operate the tap while the wax is cold as this may damage the tap.
Symbols Dened
WARNING EARTH BIOHAZARDRISK OF
HOT
SURFACE
ELECTRIC SHOCK
3
Electrical Requirements
THIS INSTRUMENT MUST BE GROUNDED
Before connection please ensure that the line supply corresponds to the power requirements below:
Power: 480W Supply requirements: 110 - 120 V or 220 - 240 V ~ 50/60Hz
The unit is provided with three power cables consisting of a UK 3-pin and a “Schuko” 2-pin plug for 230 V installations and a NEMA 5-15 plug for 120 V installations.
Choose the power cable appropriate for your electrical installation and discard the other. Should neither power cable be suitable for connecting to the power supply, replace the plug with a suitable alternative.
THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN.
NOTE: Refer to the equipment rating plate to ensure that the plug and fusing are suitable for the voltage and
wattage stated. The wires in the mains cable are as follows:
230V 120V BROWN - HOT/LIVE BLACK - HOT/LIVE
BLUE - NEUTRAL WHITE - NEUTRAL GREEN/YELLOW – EARTH GREEN - EARTH
The appropriate power cable and power adaptor combination should be connected to the instrument BEFORE connection to the mains supply. Should the mains lead require replacement, a heat resistant cable of 1.25mm² (AWG16) of harmonised code H05VV-F connected to an IEC320 plug should be used.
IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN
THIS EQUIPMENT MUST NOT BE FLASH TESTED
4