Thank you for purchasing our generator. We want to help you get the best results from your new
generator and to operate it safely. This manual contains the information on how to do that; please read
it carefully. This owner’s manual describes the operation and maintenance of the Generator. All
information in this publication is based on the latest product information available at the time of printing.
We reserve the right to make changes at any time without notice and without incurring any obligation.
No part of this publication may be reproduced without written permission. This manual should be
considered a permanent part of the generator and should remain with it even if ownership changes.
SAFETY
Your safety and the safety of others are very important. We have provided important safety messages
in this manual and on the generator. Please read these messages carefully. A safety message alerts
you to potential hazards that could hurt you or others. Each safety message is preceded by a safety
alert symbol and one of three words: DANGER, WARNING, or CAUTION.
DANGER - You WILL be KILLED or SERIOUSLY HURT if you don’t follow instructions.
WARNING - You CAN be KILLED or SERIOUSLY HURT if you don’t follow instructions.
CAUTION - You CAN be HURT if you don’t follow instructions.
Each message tells you what the hazard is, what can happen, and what you can do to avoid or reduce
injury.
Damage Prevention Messages
You will also see other important messages that are preceded by the word NOTICE.
This word means:
NOTICE - Your generator or other property could be damaged if you don’t follow instructions.
The purpose of these messages is to help prevent damage to your generator, other property, or the
environment.
DANGER - CARBON MONOXIDE HAZARDS
• Always use generators outdoors, away from doors, windows and vents.
• NEVER use generators in homes, garages, basements, crawl spaces, or other enclosed or
partially enclosed areas, even with ventilation.
• Follow manufacturer’s instructions.
• Install carbon monoxide (CO) alarms in your home, following manufacturer’s instructions.
WARNING - ELECTRICAL HAZARDS:
• Keep the generator dry. Operate on a dry surface under an open, canopy-like structure.
• Dry your hands before touching the generator.
• Plug appliances directly into generator or use a heavy-duty outdoor-rated extension cord.
• NEVER plug the generator into a wall outlet. This practice, known as back feeding, can cause an
electrocution risk to utility workers and others served by the same utility transformer.
• If necessary to connect generator to house wiring to power appliances, have a qualified
electrician install appropriate equipment.
CAUTION - FIRE HAZARDS:
• Before refueling the generator, turn it off and let it cool. Fuel spilled on hot engine parts could
ignite.
• Always store fuel outside of living areas in properly labeled, non-glass containers.
• Store fuel away from any fuel-burning appliance.
2
Table Of Contents
SAFETY
SAFETY LABEL LOCATION
SAFETY INFORMATION
Component Identification
CONTROLS
Engine Switch
Recoil Starter
Fuel Valve
Choke Rod
Circuit Breaker
Ground Terminal
Oil Alert System
Pilot Lamp
DC Terminals
DC Circuit Protector
GENERATOR USE
Connections to a Building’s Electrical System
Generator Ground Circuit
AC Applications
AC Operation
DC Operation
Disconnecting the battery cables
PREOPERATION CHECK
Engine Oil
Fuel Recommendation
STARTING THE ENGINE
STOPPING THE ENGINE
MAINTENANCE
Maintenance Schedule
Engine Oil Change
Air Cleaner Service
Fuel Sediment Cup Cleaning
Spark Plug Service
These labels warn you of potential hazards that can cause serious injury. Read them carefully. If a
label comes off or becomes hard to read, contact your generator dealer for a replacement.
4
WARNING!
Do not connect to a building’s electrical system unless a transfer switch has been installed by
a qualified electrician. Using a generator or an electrical appliance in wet conditions such as
rain or snow or near a pool or sprinkler system, or when your hands are wet, could result in
electrocution. Keep the generator dry.
SAFETY INFORMATION
Generators are designed to give safe and dependable service if operated according to instructions.
Read and understand this owner’s manual before operating your generator. You can help prevent
accidents by being familiar with your generator’s controls and by observing safe operating procedures.
Operator Responsibility
Know how to stop the generator quickly in case of emergency. (See Page 14)
Understand the use of all generator controls, output receptacles and connections.
Be sure that anyone who operates the generator receives proper instruction. Do not let children
operate the generator.
Carbon Monoxide Hazards
Exhaust contains poisonous carbon monoxide, a colorless and odorless gas. Breathing exhaust can
cause loss of consciousness and may lead to death. If you run the generator in an area that is confined,
or even partially enclosed, the air you breathe could contain dangerous amounts of exhaust gas. To
keep exhaust gas from building up, provide adequate ventilation.
Electric Shock Hazards
The generator produces enough electric power to cause a serious shock or electrocution if misused.
Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or
sprinkler system, or when your hands are wet, could result in electrocution. Keep the generator dry.
If the generator is stored outdoors, unprotected from the weather, check all electrical components on
the control panel, before each use. Moisture or ice can cause a malfunction or short circuit in electrical
components which could result in electrocution.
Do not connect to a building’s electrical system unless a transfer switch has been installed by a
qualified electrician.
Fire and Burn Hazards
The exhaust system gets hot enough to ignite some materials.
• Keep the generator at least 1 meter (3 feet) away from buildings and other equipment during
operation.
• Do not enclose the generator in any structure.
• Keep flammable materials away from the generator.
The muffler becomes very hot during operation and remains hot for a while after stopping the engine.
• Be careful not to touch the muffler while it is hot.
• Let the engine cool before storing the generator indoors.
Gasoline is extremely flammable and is explosive under certain conditions.
5
• Do not smoke or allow flames or sparks where the generator is refueled or where gasoline is
stored.
• Refuel in a well-ventilated area with the engine stopped.
Fuel vapors are extremely flammable and may ignite after the engine has started. Make sure that any
spilled fuel has been wiped up before starting the generator.
Record the engine serial number for your future reference. (See Page 6) Refer to this serial number
when ordering parts, and when making technical requests.
Engine serial number:
6
CONTROLS
Engine Switch
To start and stop the engine.
Switch position:
OFF: To Stop the engine. Key can be
removed/inserted.
ON: To run the engine after starting.
START: To start the engine by turning
the starter motor.
Return the key to the ON position once the engine has started. Do not use the starter for
m or e t h an 5 seconds at a time. If the engine fails to start, release the switch and wait 10 seconds
before operating the starter again.
Recoil Starter
To start the engine. Pull the starter grip lightly
until resistance is felt. then pull briskly.
NOTICE
Do not allow the starter to snap
Back against the engine. Return it gently to
prevent damage to the starter.
Fuel Valve
The fuel valve is located between the fuel
tank and carburetor. When the valve lever
is in the ON position, fuel is allowed to flow
from the fuel tank to the carburetor. Be sure
to return the lever to OFF after stopping the
engine.
7
Choke Rod
The choke is used to provide an enriched fuel
mixture when cold starting. The choke can be
opened by moving the choke rod to the right
and closed by moving the choke rod to the
left.
Circuit Breaker
The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of
the generator at the receptacle. lf the circuit breaker is s w it c h e d O F F a u t o ma t i c a ll y , ch e c k t h a t
the appliance is working properly and does not exceed the rate d load c a p ac it y of the circuit
befo re switching the circuit breaker ON again.
Ground Terminal
The generator ground terminal is connected to the frame of the generator, on a metal
non-current carrying part of the generator, and the ground terminals of each receptacle.
Oil Alert System
The Oil Alert system is designed to prevent engine damage caused by an insufficient amount of oil in
the crankcase. Before the oil level in the crankcase can fall below a safe limit, the Oil Alert system will
automatically shut down the engine (the engine switch will remain in the ON position). The QB1300
does not have this feature.
Pilot Lamp
The pilot lamp is illuminated when the generator is operating normally.
DC Terminals
The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The terminals are
colored red to identify the positive (+) terminal and black to identify the negative (-) terminal. The
8
battery must be connected to the generator DC terminals with the proper polarity (battery positive to
generator red terminal and battery negative to the generator black terminal.)
DC Circuit Protector
The DC circuit protector automatically shuts off the DC battery charging circuit when the generator is
overloaded, when there is a problem with the battery or the connections between the battery and the
generator are improper.
GENERATOR USE
Connections to a Building’s Electrical System
Connections for standby power to a building’s electrical system must be made by a qualified electrician.
The connection must isolate the generator power from utility power, and must comply with all
applicable laws and electrical codes.
Improper connections to a building’s electrical system can allow electrical current from the
generator to back feed into the utility lines. Such back feed may electrocute utility company
workers or others who contact the lines during a power outage. Consult the utility company or
a qualified electrician.
Improper connections to a building’s electrical system can allow electrical current from the
utility company to back feed into the generator. When utility power is restored, the generator
may explode, burn, or cause fires in the building’s electrical system.
In some areas, generators are required by law to be registered with local utility companies. Check
local regulations for proper registration and use procedures.
Generator Ground Circuits
Portable generators have a system ground that connects the generator frame components to the
ground terminals in the AC output receptacles. The system ground is not connected to the AC neutral
wire. Local regulations, codes or laws may require that the ground system be connected to the AC
neutral wire. If the generator is tested by a receptacle tester, it will not show the same ground circuit
condition as for a home receptacle. If local regulations, codes, or laws require the system ground to be
connected to the AC neutral wire, consult a qualified electrical or electrical inspector. Provide him with
the electrical wiring diagram in this manual.
The ground terminal can be used to ground the generator or bond the frame of the generator to the
frame of a vehicle, but only if it is required by local law or electrical code. Before using the ground
terminal consult a qualified electrician or electrical inspector for regulations in your area.
AC Applications
Before connecting an appliance or power cord to the generator make sure that it is in good working
order. Faulty appliances or power cords can create a potential for electrical shock. If an appliance
begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect
the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the
generator has been exceeded. Make sure that the electrical rating of the tool or appliance does not
9
exceed that of the generator, Never exceed the maximum power rating of the generator. Power levels
between rated and maximum may be used for no more than 5 minutes.
NOTICE
Substantial overloading will open the circuit breaker. Exceeding the time limit for maximum
power operation or slightly overloading the generator may not switch the circuit breaker OFF,
but will shorten the service life of the generator.
Limit operation requiring maximum power to 5 minutes.
Maximum power is: See specifications. (Page 21)
For continuous operation, do not exceed the rated power.
Rated power is: See specifications. (Page 21)
In either case, the total power requirements (VA) of all appliances connected must be considered.
Appliance and power tool manufactures usually list rating information near the model number or serial
number.
AC Operation
1. Start the engine.
2. Switch ON the AC circuit breaker.
3. Plug in the appliance.
Most motorized appliances require more than their rated wattage for startup. Do not exceed the
current limit specified for any one receptacle. If an overloaded circuit causes the AC circuit breaker to
switch OFF, reduce the electrical load on the circuit, wait a few minutes and then reset the
circuit-breaker.
DC operation
The DC terminals may ONLY be used for charging 12 volt automotive-type batteries.
The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide
adequate ventilation when charging or using batteries.
Connecting the battery cables:
1. Before connecting charging cables to a battery that is installed in a vehicle, disconnect the
vehicle’s grounded battery cable.
2. Connect the positive (+) battery cable to the battery positive (+) terminal.
3. Connect the other end of the positive (+) battery cable to the generator positive (+) terminal.
4. Connect the negative (-) battery cable to the battery negative (-) terminal.
5. Connect the other end of the negative (-) battery cable to the generator negative (-) terminal.
6. Start the generator.
NOTICE
Do not start the vehicle while the battery charging cables are connected and the generator is
running. The vehicle or the generator may be damaged.
An overloaded DC circuit, excessive current draw by the battery, or wiring problem will trip the DC
circuit protector (PUSH button extends out). If this happens, wait a few minutes before pushing in the
circuit protector to resume operation. If the circuit protector continues to go OFF, discontinue charging
and contact your authorized generator dealer.
10
Disconnecting the battery cables:
1. Stop the engine.
2. Disconnect the negative (-) battery cable from the generator negative (-) terminal.
3. Disconnect the other end of the negative (-) battery cable from the battery negative (-) terminal.
4. Disconnect the positive (+) battery cable from the generator positive (+) terminal.
5. Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal.
6. Connect the vehicle ground cable to the battery negative (-) terminal.
7. Reconnect the vehicle grounded battery cable.
PRE-OPERATION CHECK
Engine oil
NOTICE
Engine oil is a major factor affecting engine performance and service life. Non-detergent and
2-stroke engine oils will damage the engine and should not be used.
Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
Use 4-stroke oil, or equivalent high detergent, premium quality motor oil certified to meet or exceed U.S.
automobile manufacturer’s requirements for Service Classification SG, SF/CC, and CD. Motor oils
classified SG, SF/CC; CD will show this designation on the container. (1) SG.SF/CC.CD SINGLE
VISCOSITY (2) SG.SF/CC.CD MULTI VISCOSITY. SAE 10W-30 is recommended for general,
all-temperature use. Other viscosities shown in the chart may be used when the average temperature
in your area is within the indicated range.
1. Remove the oil filler cap and wipe the dipstick clean.
2. Check the oil level by inserting the dipstick into the filler neck without screwing it in.
3. If the level is low, fill to the top of the oil filler neck with the recommended oil.
11
Fuel Recommendation
1. Check the fuel level gauge.
2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer.
WARNING
Gasoline is extremely flammable and is explosive under certain conditions. Refuel in a
well-ventilated area with the engine stopped. Do not smoke or allow flames or sparks in the
area where the engine is refueled or where gasoline is stored. Do not overfill the fuel tank
(there should be no fuel in the filler neck). After refueling, make sure the tank cap is closed
properly and securely. Be careful not to spill fuel when refueling. Spilled fuel or fuel vapor may
ignite. If any fuel is spilled, make sure the area is dry before starting the engine. Avoid repeated
or prolonged contact with skin or breathing of vapor.
KEEP OUT OF REACH OF CHILDREN.
Fuel tank capacity: See specifications. (Page 21)
Use gasoline with a pump octane rating of 86 or higher. We recommend unleaded gasoline because it
produces fewer engine and spark plug deposits and extends exhaust system life. Never use stale or
contaminated gasoline or oil/gasoline mixture. Avoid getting dirt or water in the fuel tank. Occasionally
you may hear light knocking or pinging, (metallic rapping noise) while operating under heavy loads.
This is no cause for concern. If knocking or pinging occurs at a steady engine speed, under normal
load, change brands of gasoline. If knocking or pinging persists, contact your authorized QBP
generator dealer.
NOTICE
Running the engine with persistent spark knock or pinging can cause engine damage.
Running the engine with persistent spark knock or pinging is misuse, and the Limited Warranty does
not cover parts damaged by misuse.
Oxygenated Fuels
Some gasoline is being blended with alcohol or an ether compound to increase the octane. This
gasoline is collectively referred to as oxygenated fuels. Some areas of the United States use
oxygenated fuels to help meet clean air standards. If you use an oxygenated fuel, be sure its pump
octane rating is 86 or higher.
Ethanol (ethyl or grain alcohol)
12
Gasoline containing more than 10% ethanol by volume may cause starting and/or performance
problems. Gasoline containing ethanol may be marketed under the name Gasohol.
Methanol (methyl or wood alcohol)
Gasoline containing methanol must contain co solvents and corrosion inhibitors to protect the fuel
system. Gasoline containing more than 5% methanol by volume may cause starting and/or
performance problems and may damage metal, rubber and plastic parts of your fuel system.
MTBE (methyl tertiary butyl ether)
Your may use gasoline containing up to 15% MTBE by volume. Before using an oxygenated fuel, try to
confirm the fuel’s contents. Some states require this information to be posted on the pump. If you
notice any undesirable operating symptoms, switch to a conventional unleaded gasoline.
Fuel system damage or performance problems resulting from the use of an oxygenated fuel are not
the responsibility of factory and are not covered under warranty.
NOTICE
Oxygenated fuels can damage paint and plastic. Be careful not to spill fuel when filling your
fuel tank. Damage caused by spilled fuel is not covered under warranty.
STARTING
Recoil Start
1. Make sure to disconnect all electrical loads from panel receptacles. The generator may be hard
to start if a load is connected.
2. Turn the fuel valve to the ON position.
3. The automatic choke will be closed if the engine is cold. If you want to operate the choke
manually, move the choke rod out of the CLOSED position.
4. Turn the engine switch to the ON position.
5. Pull the starter grip lightly until resistance is felt, then pull briskly.
NOTICE
Do not allow the starter grip to snap back against the engine. Return it gently to prevent
damage to the starter or housing.
6. If you have manually closed the choke, move it to the OPEN position as the engine warms up.
Electric Start
1. Make sure to disconnect all electrical loads from panel receptacles. The generator may be hard
to start if a load is connected.
2. Turn the fuel valve to the ON position.
3. The automatic choke will be closed if the engine is cold. If you want to operate the choke
manually, move the choke rod out of the CLOSED position.
4. Turn the engine switch to the START position.
5. Return the key to the ON position once the engine has started. Do not use the starter
for mo re than 5 seconds at a time. If the engine fails to start, release the switch and wait 10
seconds before operating the starter again.
6. If you have manually closed the choke, move it to the OPEN position as the engine warms up.
13
STOPPING
In an emergency:
1. To stop the engine in an emergency, turn the engine switch to the OFF position.
In normal use:
1. Turn the AC circuit breaker to the OFF position.
2. Disconnect all electrical loads from panel receptacles.
Disconnect DC battery charging cables.
3. Turn the engine switch to the OFF position.
4. Turn the fuel valve to the OFF position.
MAINTENENCE
Periodic maintenance and adjustment is necessary to keep the generator in good operating condition.
Perform the service and inspection at the intervals shown in the Maintenance schedule below.
Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any
maintenance. If the engine must be run, make sure the area is well ventilated.
NOTICE
Use only genuine factory parts or their equivalent for maintenance or repair. Replacement parts which
are not of equivalent quality may damage the generator.
14
Maintenance Schedule
Notes
1) Service more frequently when used in dusty areas.
2) These items should be serviced by an authorized generator dealer, unless owner has proper
tools and is mechanically proficient.
3) For professional commercial use, log hours of operation to determine proper maintenance
intervals.
Engine oil change
Drain the oil while the engine is warm to assure rapid and complete draining.
1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil.
2. Reinstall the drain plug and sealing washer. Tighten the plug securely.
3. Refill with the recommended oil and check the level.
Oil capacity: See specifications. (Page 21)
Used motor oil may cause skin cancer if repeatedly left in contact with the skin for prolonged
periods. Although this is unlikely unless you handle used oil on a daily basis, it is still
advisable to thoroughly wash your hands with soap and water as soon as possible after
handling used oil.
15
Please dispose of used motor oil in a manner that is compatible with the environment. We suggest you
take it in a sealed container to your local service station or recycling center for disposal. Do not throw it
in the trash or pour it on the ground.
Air cleaner service
A dirty air cleaner will restrict air flow to the carburetor. To prevent carburetor malfunction, service the
air cleaner regularly. Service more frequently when operating the generator in extremely dusty areas.
Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion.
Use only soapy water or nonflammable solvent.
NOTICE
Never run the generator without the air cleaner. Rapid engine wear will result.
1. Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element.
2. Wash the element in a solution of household detergent and warm water, then rinse
thoroughly; or wash in nonflammable or high flash point solvent.
3. Allow the element to dry thoroughly.
4. Soak the element in clean engine oil and squeeze out the excess oil. The engine will smoke
during initial start-up if too much oil is left in the element.
5. Reinstall the air cleaner element and the cover.
16
Fuel Sediment Cup Cleaning
The sediment cup prevents dirt or water, which may be in the fuel tank, from entering the carburetor. If
the engine has not been run for a long time, the sediment cup should be cleaned.
1. Turn the fuel valve to the OFF position. Remove the sediment cup, O-ring, and filter.
2. Clean the sediment cup, O-ring, and filter in nonflammable or high flash point solvent.
3. Reinstall the filter, O-ring, and sediment cup.
4. Turn the fuel valve ON and check for leaks.
Spark Plug Service
Recommended spark plugs: MP160; BPR6ES (NGK)
MP240, MP340, MP390; BPR5ES (NGK)
MP270; BP6ES (NGK)
To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. I f
the engine has been running, the muffler will be very hot. Be careful not to touch the muffler.
1. Remove the spark plug cap.
2. Clean any dirt from around the spark plug base.
3. Use the wrench supplied in the tool kit to remove the spark plug.
4. Visually inspect the spark plug. Discard it if t h e i n s u l a t o r i s c r a c k e d or chipped.
5. Clean the spark plug with a wire brush if it is to be reused.
6. Measure the plug gap with a feeler gauge. The gap should be: 0.70-0.80 mm (0.028-0.031 in)
7. Correct as necessary by carefully bending the side electrode.
8. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to
prevent cross-threading.
9. After the spark plug is seated, tighten with a spark plug wrench to compress the washer.
• If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress the
washer.
• If reinstalling a used spark plug, tighten 1/8-1/4 turns after the spark plug seats to
compress the washer.
17
NOTICE
The spark plug must be securely tightened. An improperly tightened spark plug can become
very hot and could damage the engine. Never use spark plugs which have an improper heat
range. Use only the recommended spark plugs or equivalent.
TRANSPORTATION/STORAGE
When transporting the generator, turn the engine switch and the fuel valve OFF. Keep the generator
level to prevent fuel spillage. Fuel vapor or spilled fuel may ignite.
Contact with a hot engine or exhaust system can cause serious burns or fires. Let the engine
cool before transporting or storing the generator.
Take care not to drop or strike the generator when transporting. Do not place heavy objects on the
generator.
Before storing the unit for an extended period:
1. Be sure the storage area is free of excessive humidity and dust.
2. Service according to the table below:
18
Gasoline is extremely flammable and is explosive under certain conditions Perform this task in
a well ventilated area with the engine stopped. Do not smoke or allow flame s or sparks in the area
during this procedure.
1. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container.
2. Change the engine oil.
3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder.
Crank the engine several revolutions to distribute the oil, and then reinstall the spark plug.
4. Slowly pull the starter grip until resistance is felt. At this point, the piston is com ing
up on its compression stroke a nd b oth the int ake and exhaust valves are closed. Storing the engine in
this position will help to protect it from internal corrosion.
Automatic Washer 2300 1150
Blender 900 300
Ceiling Fan 1200 800
Clock Radio 100 100
Clothes Dryer (Gas) 1200 700
Coffee pot (10 cup) 1200 1200
Coffee pot (4 cup) 650 650
Color Television 300 300
Curling iron 65 65
Dehumidifier 800 650
Dishwasher (Cool Dry) 1400 700
Electric blanket 400 400
Electric Clothes Dryer 6750 5400
Electric Fry Pan 1500 1500
Electric Range (8-inch element) 2100 2100
Frying pan 1200 1200
Garage door opener (1/3 HP) 350 250
George Forman type grill 2000 1300
Hair dryer 1200 1200
Heating pad 350 350
Ice maker 400 300
Iron 1200 1200
Lights As indicated on bulb As indicated on bulb
Microwave (full-size) 1500 1500
Microwave (small) 800 800
Refrigerator or Freezer 2200 700
Refrigerator or Freezer – Energy Star 1200 132-192
Refrigerator/freezer (medium) 900 500
Small Appliance 1700 200
Space heater 1800 1800
Table fan 2000 800
Toaster (2-slice) 1600 1000
Vacuum cleaner 1200 1200
Appliances
Surge Wattage
(Startup) Running Wattage
22
Electronics
Surge Wattage
CD player 100 100
Color Television 300 300
Desktop Computer 600 to 800 600 to 800
DVD player 100 100
Fax 600 to 800 600 to 800
Laptop Computer 200 to 250 200 to 250
Monitor (CRT) 200 to 250 200 to 250
Printer 400 to 600 400 to 600
Radio 50-200 50-200
Receiver 450 450
Stereo 100 100
Television - Color 300 300
Television (20") 130 130
Television (big screen) 400 400
VCR 100 100
Video game console 100 100
X-Box 360 game console 200 170
(Startup) Running Wattage
Heating and Air
Surge Wattage
Furnace Fan (Gas or fuel oil): 1/2 HP 2350 875
Furnace Fan (Gas or fuel oil): 1/3 HP 1400 700
Furnace Fan (Gas or fuel oil): 1/4 HP 1000 600
Furnace Fan (Gas or fuel oil): 1/6 HP 750 500
Furnace Fan (Gas or fuel oil): 1/8 HP 500 300
Portable Air Conditioner 7000BTU 1800 1120
Portable Air Conditioner 9000BTU 2100 1400
Portable Air Conditioner: 10,000 BTU 2200 1500
Portable Heater (Kerosene, Diesel Fuel): 150,000
BTU 1000 625
Portable Heater (Kerosene, Diesel Fuel): 50,000 BTU 600 400
Portable Heater (Kerosene, Diesel Fuel): 90,000 BTU 725 500
RV Air Conditioner 13,500 BTU 2200 1500
Space Heater 800 800
(Startup) Running Wattage
23
Power Equipment
Surge Wattage
Air Compressor (1 HP) 4500 1600
Air Compressor (1/2 HP) 1600 975
Battery Charger: 100 Amp with 300 Amp Boost 2400/7800 2400/7800
Battery Charger: 15 Amp 380 380
Battery Charger: 60 Amp with 250 Amp Boost 1500/5750 1500/5750
Belt Sander 2400 1200
Bench Grinder (8") 2500 1400
Circular Saw, Heavy Duty (7 1/4") 2300 1400
Drill: 1/2in., 5.4 Amps 900 600
Drill: 3/8in., 4 Amps 600 440
Electric Chain Saw (14" , 2 HP) 1100 1100
Electric Chain Saw: 14in. Bar, 2 HP 1100 1100
Electric Welder: 200 Amp AC 9000 9000
Electric Welder: 230 Amp AC at 100 Amp 7800 7800
High-pressure Washer (1 HP) 3600 1200
Mitre Saw 2400 1650
Power drill 1500 500
Power hand sander 1500 500
Power hand saw 1800 600
Pressure Washer (1 HP) 3600 1200
Table Saw (10") 4500 1800
(Startup) Running Wattage
Well & Sump Pumps
Sump Pump: 1/3 HP 1300 800
Sump Pump: 1/2 HP 2150 1050
Well Pump: 1/3 HP 2000 1000
24
Surge Wattage
(Startup) Running Wattage
Limited Warranty
Queen Bee Power™ Generators are warranted by Jae Enterprises, Inc. to the original retail consumer against
defects in material and workmanship for a period of one (1) year from the date of retail purchase and is not
transferable. This one year warranty applies only to products used in consumer applications. If this generator is
used in a commercial application, then the period of warranty coverage is limited to six (6) months from the date
of purchase. The replacement parts will be provided if the generator is found to be properly installed,
maintained and operated in accordance with normal procedures. This warranty does not apply to malfunctions
caused by damage, unreasonable use, misuse, repair or service by unauthorized persons, or normal wear and
tear.
THERE IS NO OTHER EXPRESS WARRANTY. Any implied or statutory warranties, including any warranty or
merchantability or fitness of purposes are expressly limited to the duration of the warranty. In no event is Jae
Enterprises, Inc. liable for incidental or consequential loss or damage arising from injury, loss of use, loss of
time, rentals, profits, or income to the customer as a result of a failure of any component or part. Purchase of the
generator constitutes that you have read, fully understand and agree to these terms of sale. There are inherent
dangers involved in the operation of a gas generator. Purchaser shall use these products at their own risk. Jae
Enterprises, Inc. will not be held liable under any circumstance for incidental or consequential loss or damage or
injury due to the direct or indirect use, misuse or abuse of any generator purchased from Jae Enterprises, Inc.,
including any malfunction.
PURCHASERS RESPONSIBILITY: You must inspect all equipment before using it and take full responsibility
for assuring that the generator is in good working order and safe to use. You further understand that you are
responsible for damage to equipment. Purchaser understands the nature of generator operation and
acknowledges that Purchaser is qualified to operate said generator, and is in proper physical condition to
participate in such activity. Purchaser agrees to assume all risks when allowing others to operate Purchaser's
generator. If Purchaser is not familiar with the nature of generator operation, Purchaser should seek
professional instruction before operating a generator.
WHAT IS COVERED: Replacement Parts Only
WHAT IS NOT COVERED: This warranty does not extend to parts affected or damaged by accident and/or
collision, normal wear, fuel contamination, use in an application for which the product was not designed or any
other misuse, incorporation or use of unsuitable attachments or parts, unauthorized alteration, or any causes
other than defects in material or workmanship of the product. Labor costs for replacement of parts.
Transportation charges for defective products. Transportation charges to consumer for repaired products.
Brushes, fuses, rubber feet, and receptacles. Damages caused by abuse, accident, improper repair, or failure
to perform normal maintenance. Sales outside of the United States or Canada. Any other expense including
consequential damages, incidental damages, or incidental expenses, including damage to property.
HOW TO OBTAIN WARRANTY PARTS: Contact the authorized Queen Bee Power™ dealer from whom you
purchased your generator. Dated proof of purchase is required for any and all warranty claims. Replacement
parts are available from Jae Enterprises, Inc.. If you are unable to contact your original dealer, contact Jae
Enterprises, Inc.. This warranty gives you specific legal rights and you may also have other rights which vary
from state to state.