FR SÉCHEUSE Á CHARGEMENT FRONTAL
ES SECADORA DE CARGA FRONTAL
INSTALLATION INSTRUCTIONS
INSTRUCTIONS D’INSTALLATION
INSTRUCCIONES DE INSTALACIÓN
A11199802 April 2018
2
Important Safety Instructions
WARNING
For your safety, the information in this manual must be followed to minimize the risk of
fire or explosion or to prevent property damage, personal injury or loss of life. DO NOT
store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
Safety Precautions
DO NOT attempt to install or operate
your unit until you have read the safety
precautions in this manual. Safety items
throughout this manual are labeled with a
Danger, Warning, or Caution based on the
risk type.
Definitions
This is the safety alert symbol. It is
used to alert you to potential personal injury
hazards. Obey all safety messages that
follow this symbol to avoid possible injury
or death.
DANGER
DANGER indicates an imminently hazardous situation which, if not avoided,
will result in death or serious injury.
Read all the following instructions before installing and using this appliance.
• Destroy the carton and plastic bags after the laundry center is unpacked. Children
might use them to play. Cartons covered with rugs, bedspreads, or plastic sheets
can become airtight chambers causing suffocation. Place all materials in a garbage
container or make materials inaccessible to children.
• Clothes dryer installation and service must be performed by a qualified installer,
service agency or the gas supplier.
• Install the clothes dryer according to the manufacturer’s instructions and local codes.
• The electrical service to the dryer must conform with local codes and ordinances
and the latest edition of the National Electrical Code, ANSI/NFPA 70, or in Canada,
the Canadian Electrical Code CSA C22.1 part 1.
• The gas service to the dryer must conform with local codes and ordinances and the
latest edition of the National Fuel Gas Code ANSI Z223.1/NFPA 54, or in Canada,
the Natural Gas and Propane Installation Code, CSA B149.1. An individual manual
shutoff valve must be installed within 6 ft (1.83 m) of the dryer in accordance with the
National Fuel Gas Code, ANSI Z223.1/NFPA 54.
• The dryer is designed under ANSI Z21.5.1/CSA 7.1 or UL 2158 - CAN/CSA C22.2
No. 112 (latest editions) for HOME USE only. This dryer is not recommended for
commercial applications such as restaurants, beauty salons, etc.
• DO NOT install a clothes dryer with flexible plastic or flexible foil venting
material. Flexible venting materials are known to collapse, be easily crushed
and trap lint. These conditions will obstruct clothes dryer airflow and increase the risk of fire.
• DO NOT stack a dryer on top of washer already installed on pedestal. DO NOT
stack washer on top of dryer. DO NOT stack washer on top of another washer.
The instructions in this manual and all other literature included with this dryer are not
meant to cover every possible condition and situation that may occur. Good safe practice and caution MUST be applied when installing, operating and maintaining any appliance.
3
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.
4
Installation Requirements
Please read and save
this guide
Thank you for choosing Electrolux, the
premium brand in home appliances. These
Installation Instructions are part of our
commitment to customer satisfaction and
product quality throughout the life of your
new appliance.
Installation Checklist
Exhaust Venting
Free-flowing, clear of lint buildup 4 inch (102 mm) rigid metal or
semi-rigid metal transition ducting
of minimal length and turns
NO foil or plastic venting material Approved vent hood exhausted to
outdoors
Leveling
Dryer is level, side-to-side and front-
to-back
Cabinet is sitting solid on all corners
Gas Supply (Gas Dryer)
Manual shutoff valve present in
supply
Tools and materials needed for installation:
All connections sealed with approved
sealer and wrench tight
Conversion kit for LP GAS system Gas supply turned on No leaks present at all connections
- check with soapy water, NEVER
check with flame
Water Hookup (Select Models)
Inspect hoses for proper placement
of rubber washers
Water supply is turned on Check for leaks Steam model dryers require use of
Care Guide read thoroughly
Door latches and drum tumbles
when cycle starts
Registration card sent in
Installation Requirements
5
Tools and materials needed for
installation:
Adjustable
pliers
Pipe wrench
for gas
supply
semi-rigid metal exhaust duct work
4 in.
(10.2 cm)
clamp
Phillips,
straight, &
square bit
screwdrivers
or
LP-resistant
thread tape
(for natural
gas or
LP supply)
4 inch, rigid metal or
gas line
shutoff valve
(gas dryer)
Adjustable
wrench
Carpenter’s
level
½” NPT
union flare
adapters (x2)
and flexible
gas supply line
(gas dryer)
3-wire or 4-wire
240 volt cord kit
(electric dryer)
ASSEMBLY HOSE
KIT - P/N 5304495002,
for steam models only,
is not included and
must be purchased
separately.
WARNING
• Failure to follow safety warnings
exactly could result in serious injury,
death, or property damage.
• DO NOT install a booster fan in
dryer exhaust duct.
• Install all clothes dryers in accordance with the installation instructions in this manual.
FIRE HAZARD
Optional
universal
accessory
wrench
or
External
vent hood
Metal foil
tape (not
duct tape)
Electrical system
requirements
NOTE
Because of potentially inconsistent voltage
capabilities, the use of this dryer with power
created by gas powered generators, solar
powered generators, wind powered generators or any other generator other than the
local utility company is not recommended.
Electrical Requirements For
Electric Dryer:
CIRCUIT - Individual 30 amp. branch circuit
fused with 30 amp. time delay fuses or
circuit breakers. Use separately fused
circuits for washer and dryer. DO NOT
operate washer and dryer on same circuit.
POWER SUPPLY - 3-wire or 4-wire,
120/240 volt, single phase, 60 Hz, Alternating Current.
NOTE
A 120/208 volt, single phase, 60 Hz,
Alternating Current supply may be used on
dryers marked for use on rating plate.
IMPORTANT
Dryer is internally grounded to neutral
unless it was manufactured for sale in
Canada.
Only a 4-conductor cord shall be used
when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding
through the neutral link is prohibited for: (1)
new branch circuit installations, (2) mobile
homes, (3) recreational vehicles, and (4)
areas where local codes DO NOT permit
grounding through the neutral.
6
Installation Requirements
3-WIRE POWER SUPPLY CORD
(not supplied)
3-wire receptacle
(NEMA type 10-30R)
The dryer MUST employ a 3-conductor
power supply cord NEMA 10-30 type
SRDT rated at 240 volt AC minimum, 30
amp, with 3 open end spade lug connectors with upturned ends or closed
loop connectors and marked for use with
clothes dryers. For 3-wire cord connection
instructions see ELECTRICAL CONNECTIONS FOR A 3-WIRE SYSTEM.
OUTLET RECEPTACLE - NEMA 10-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
4-WIRE POWER SUPPLY CORD
(not supplied)
4-wire receptacle
(NEMA type 14-30R)
The dryer MUST employ a 4-conductor
power supply cord NEMA 14-30 type
SRDT or DRT (as required) rated at 240
volt AC minimum, 30 amp, with 4 open
end spade lug connectors with upturned
ends or closed loop connectors and
marked for use with clothes dryers. For
4-wire cord connection instructions see
ELECTRICAL CONNECTIONS FOR A
4-WIRE SYSTEM.
Electrical Requirements For Gas
Dryer:
CIRCUIT - Individual, properly polarized
and grounded 15 amp. branch circuit
fused with 15 amp. time delay fuse or
circuit breaker.
POWER SUPPLY - 2-wire, with ground,
120 volt, single phase, 60 Hz, Alternating
Current.
POWER SUPPLY CORD - Dryer is equipped
with 120 volt 3-wire power cord.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
Grounding type wall receptacle
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Power cord with
3-prong grounded plug
NOTE
Dryers manufactured for sale in Canada
have factory-installed, 4-wire power
supply cord (NEMA 14-30).
OUTLET RECEPTACLE - NEMA 14-30R
receptacle to be located so the power
supply cord is accessible when the
dryer is in the installed position.
GROUNDING CONNECTION - See
“Grounding requirements” in Electrical
Installation section.
Gas supply requirements
WARNING
EXPLOSION HAZARD
Uncoated copper tubing will corrode when
subjected to natural gas, causing gas leaks.
Use ONLY black iron, stainless steel, or
plastic-coated brass piping for gas supply.
1. Installation MUST conform with local
codes, or in the absence of local
codes, with the National Fuel Gas
Code, ANSI Z223.1 (latest edition).
Installation Requirements
7
Gas supply requirements, continued
2. The gas supply line should be 1/2 inch
(1.27 cm) pipe.
3. If codes allow, flexible metal tubing
may be used to connect your dryer to
the gas supply line. The tubing MUST
be constructed of stainless steel or
plastic-coated brass.
4. The gas supply line MUST have an
individual shutoff valve installed in accordance with the B149.1, Natural Gas
and Propane Installation Code.
5. A 1/8 inch (0.32 cm) N.P.T. plugged
tapping, accessible for test gauge connection, MUST be installed immediately
upstream of the gas supply connection
to the dryer.
6. The dryer MUST be disconnected from
the gas supply piping system during
any pressure testing of the gas supply
piping system at test pressures in
excess of 1/2 psig (3.45 kPa).
7. The dryer MUST be isolated from the
gas supply piping system during any
pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.45 kPa).
8. Connections for the gas supply must
comply with the Standard for Connectors for Gas Appliances, ANSI Z21.24/
CSA 6.10.
The following are specific requirements for proper and safe operation of
your dryer.
WARNING
FIRE HAZARD
DO NOT
flexible plastic or foil venting materials.
Flexible venting materials are known to
collapse, be easily crushed and trap lint.
These conditions will obstruct clothes
dryer airflow and increase the risk of fire.
If your present system is made up of
plastic or foil duct, replace it with a
rigid or semi-rigid metal duct. Ensure
the present duct is free of any lint
prior to installing dryer duct.
install a clothes dryer with
CorrectIncorrect
Exhaust system
requirements
Use only 4 inch (102 mm) diameter
(minimum) rigid or semi rigid metal duct
and approved vent hood which has a
swing-out damper(s) that open when
the dryer is in operation. When the dryer
stops, the dampers automatically close to
prevent drafts and the entrance of insects
and rodents. To avoid restricting the outlet,
maintain a minimum of 12 inches (30.5
cm) clearance between the vent hood and
the ground or any other obstruction.
WARNING
FIRE HAZARD
Failure to follow these instructions can create excessive drying times and fire hazards.
CorrectIncorrect
WARNING
FIRE HAZARD
• Failure to follow safety warnings exactly could result in serious injury,
death, or property damage.
• DO NOT install a booster fan in dryer
exhaust duct.
• Install all clothes dryers in accordance with the installation instructions in this manual.
8
Installation Requirements
Exhaust system requirements, continued
WARNING
A clothes dryer must be exhausted
outdoors.
a chimney, a wall, a ceiling, an attic, a
crawl space or any concealed space of
a building. A clothes dryer produces
combustible lint. If the dryer is not
exhausted outdoors, some fine lint will
be expelled into the laundry area.
accumulation of lint in any area of the
home can create a health and fire hazard.
The dryer must be connected to an
exhaust outdoors. Regularly inspect the
outdoor exhaust opening and remove any
accumulation of lint around the outdoor exhaust opening and in the surrounding area.
FIRE HAZARD
DO NOT
exhaust dryer into
An
WARNING
• DO NOT allow combustible materi-
als (for example: clothing, draperies/
curtains, paper) to come in contact
with exhaust system. The dryer MUST
NOT be exhausted into a chimney,
a wall, a ceiling, or any concealed
space of a building which can accumulate lint, resulting in a fire hazard.
• DO NOT screen the exhaust ends of
the vent system, or use any screws,
rivets or other fasteners that extend
into the duct to assemble the exhaust
system. No
screen or grate
of any mesh size
is allowed to
cover the exhaust
opening. Lint can become
caught in the screen, grate, or on
the screws or rivets, clogging the
duct work and creating a fire hazard as well as increasing drying
times. Use an approved vent hood to
terminate the duct outdoors, and seal
all joints with metal foil tape. All male
duct pipe fittings MUST be installed
downstream with the flow of air.
FIRE HAZARD
WARNING
Exceeding the length of duct pipe
or number of elbows allowed in the
“MAXIMUM LENGTH” charts can cause an
accumulation of lint in the exhaust system.
Plugging the system could create a fire
hazard, as well as increase drying times.
Number of 90° turns
(10.2 cm)louvered
0125 ft. (38 m)110 ft. (33.5 m)
1115 ft. (35 m)100 ft. (30.5 m)
2105 ft. (32 m)90 ft. (27.5 m)
395 ft. (29 m)80 ft. (24.5 m)
485 ft. (26 m)70 ft. (21.5 m)
MAXIMUM LENGTH
of 4” (102 mm) Rigid Metal Duct
VENT HOOD TYPE
(Preferred)
4”
2.5”
(6.35 cm)
WARNING
• DO NOT install flexible plastic or
flexible foil venting material.
• DO NOT exceed 8 ft. (2.4 m)
duct length if installing semirigid venting.
Exhaust Direction
Directional exhausting can be accomplished by installing a quick-turn 90° dryer
vent elbow directly to exhaust outlet of
dryer. Dryer vent elbows are available
through your local parts distributor or
hardware store.
FIRE HAZARD
See also CLEARANCE
REQUIREMENTS.
Installation Requirements
Exhaust system requirements, continued
Install male fittings in correct direction:
NOTE
Use of 90° quickturn elbow required to
meet minimum installation depth.
9
WARNING
FIRE HAZARD
DO NOT install the dryer where gasoline
or other flammables are kept or stored. If
the dryer is installed in a garage, it must
be a minimum of 18 inches (45.7 cm)
above the floor. Failure to do so can result in death, explosion, fire or burns.
In installations where the exhaust system
is not described in the charts, the following
method must be used to determine if the
exhaust system is acceptable:
1. Connect an inclined or digital manometer between the dryer and the point
the exhaust connects to the dryer.
2. Set the dryer timer and temperature to
air fluff (cool down) and start the dryer.
3. Read the measurement on the manometer.
4. The system back pressure MUST
NOT be higher than 1.0 inch of water
column. If the system back pressure is
less than 1.0 inch of water column, the
system is acceptable. If the manometer
reading is higher than 1.0 inch of water
column, the system is too restrictive
and the installation is unacceptable.
CorrectIncorrect
Although vertical orientation of the exhaust
system is acceptable, certain extenuating
circumstances could affect the performance of the dryer:
• Only the rigid metal duct work should
be used.
• Venting vertically through a roof may expose the exhaust system to down drafts
causing an increase in vent restriction.
• Running the exhaust system through an
uninsulated area may cause condensation and faster accumulation of lint.
• Compression or crimping of the exhaust
system will cause an increase in vent
restriction.
• The exhaust system should be
inspected and cleaned a minimum of
every 18 months with normal usage.
The more the dryer is used, the more
often you should check the exhaust system and vent hood for proper operation
and that it is free of obstructions.
Manufactured or mobile home installation
1. Installation MUST conform to current
Manufactured Home Construction &
Safety Standard, Title 24 CFR, Part
32-80 (formerly the Federal Standard
for Mobile Home Construction and
Safety, Title 24, HUD Part 280) or
Standard CAN/CSAZ240 MH.
2. Dryer MUST be exhausted outside
(outdoors, not beneath the mobile
home) using metal ducting that will not
support combustion. Metal ducting
must be 4 inches (10.16 cm) in diameter with no obstructions. Rigid metal
duct is preferred.
3. If dryer is exhausted through the floor
and area beneath the mobile home is
enclosed, the exhaust system MUST
terminate outside the enclosure with
the termination securely fastened to a
non-combustible portion of the mobile
home structure.
4. Refer to previous sections in this guide
for other important exhaust venting
system requirements.
5. When installing a gas dryer into a mobile home, a provision must be made
for outside make up air. This provision
is to be not less than twice the area of
the dryer exhaust outlet.
6. Installer MUST anchor this (1) dryer
or (2) dryer mounted on pedestal to
the floor with approved Mobile Home
Installation Kit - P/N 137067200.
10
(0 cm)
1"
(2.5 cm)
0"
Installation Requirements
Clearance requirements
IMPORTANT
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water
or outside weather conditions.
2. In an area where it will come in contact with curtains, drapes, or anything
that will obstruct the flow of combustion and ventilation air.
3. On carpet. Floor MUST be solid with
a maximum slope of 1 inch (2.5 cm).
Installation In A Recess Or
Closet
1. A dryer installed in a bedroom,
bathroom, recess or closet, MUST be
exhausted outdoors.
2. No other fuel burning appliance shall
be installed in the same closet as the
gas dryer.
3. Your dryer needs the space around it
for proper ventilation.
DO NOT install your dryer in a closet
with a solid door.
4. Closet door ventilation required: A
minimum of 120 square inches (774.2
cm²) of opening, equally divided at the
top and bottom of the door, is required.
Openings should be located 3 inches
(7.6 cm) from bottom and top of door.
Openings are required to be unobstructed when a door is installed. A louvered
door with equivalent air openings for the
full length of the door is acceptable.
MIN INSTALLATION CLEARANCES -
Alcove 0” (0 cm) 0” (0 cm)* 0” (0 cm)n/a
Under-
Counter
Closet 0” (0 cm) 0” (0 cm)* 0” (0 cm)
•F
or other than straight back venting, a quickturn 90° dryer vent elbow must be installed to
achieve 0” (0 cm) installation.
0"
Inches (cm)
SidesRearTopFront
0” (0 cm) 0” (0 cm)* 0” (0 cm)n/a
(2.5 cm)
0"
(0 cm)
1”
(0 cm)
closet door
3"
(7.6cm)
3"
(7.6cm)
60 sq. in.
(387.1cm²)
60 sq. in.
(387.1cm²)
NOTE
To achieve an installation with 0” (0
cm) clearance for the back of the dryer
(for other than straight back venting), a
quick-turn 90° dryer vent elbow must be
installed as described previously in this
manual.
Dryer dimensions
53.2” (135 cm)*
to clear open door
31.6” (80 cm)*
to front of closed door
Installation Requirements
27.0 ”
(68.5 cm)
11
freestand dryer
on floor
floor line
dryer mounted on
optional pedestal
floor line
53.5” (136 cm)*
to clear open door
approved stacking
kit (STACKIT7X)
required for
stacked installation
floor line
32.0” (81.25 cm)*
to front of closed door
(96.5 cm)
53.25”
(135.5 cm)
75.75”
(192.5 cm)
38.0”
gas supply
pipe on rear
of gas unit
17.0”
(43 cm)
water supply
connection on
rear of unit
gas supply
pipe on rear
of gas unit
39.0”
(99 cm)
1.5”
(4 cm)
3.75”
(9.5 cm)
drain hose on
rear of unit
(34.5 cm)
to center of
rear vent
2
13.5”
electrical
supply on
rear of unit
centerline
height of
rear vent
electrical
supply on
rear of unit
centerline
height for
rear vent
power cord on
3
rear of unit
3.7”
(9.5
19.0”
(48 cm)
1
41.0”
(105 cm)
1
* Connection of water inlet hose on steam dryer adds 3/4 in. (2 cm) to installation depth.
1
Power supply cord length on gas dryer or electric Canadian dryer approximately 60
inches (152.5 cm).
2
Drain hose length on washer approximately 59 inches (150 cm).
3
Power supply cord length on washer approximately 60 inches (152.5 cm).
12
Installation Instructions
Electrical installation
The following are specific requirements for
proper and safe electrical installation of
your dryer. Failure to follow these instructions can create electrical shock and/or a
fire hazard.
WARNING
ELECTRICAL SHOCK HAZARD
• This appliance MUST be properly
grounded. Electrical shock can result
if the dryer is not properly grounded.
Follow the instructions in this manual
for proper grounding.
• DO NOT use an extension cord with
this dryer. Some extension cords
are not designed to withstand the
amounts of electrical current this dryer
utilizes and can melt, creating electrical shock and/or fire hazard. Locate
the dryer within reach of the receptacle for the length power cord to be
purchased, allowing some slack in
the cord. Refer to the pre-installation
requirements in this manual for the
proper power cord to be purchased.
WARNING
ELECTRICAL SHOCK HAZARD
• A U.L.-approved strain relief must be
installed onto power cord. If the strain
relief is not attached, the cord can
be pulled out of the dryer and can
be cut by any movement of the cord,
resulting in electrical shock.
• DO NOT use an aluminum wired
receptacle with a copper wired
power cord and plug (or vice versa).
A chemical reaction occurs between
copper and aluminum and can cause
electrical shorts. The proper wiring
and receptacle is a copper wired
power cord with a copper wired
receptacle.
Grounding requirements -
Electric dryer (USA)
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
For a grounded, cord-connected
dryer:
1. The dryer MUST be grounded. In the
event of a malfunction or breakdown,
grounding will reduce the risk of electrical shock by providing a path of least
resistance for electrical current.
2. After you purchase and install a 3 wire
or 4 wire power supply cord having an
equipment-grounding conductor and a
grounding plug that matches your wiring system, the plug MUST be plugged
into an appropriate, copper wired
receptacle that is properly installed and
grounded in accordance with all local
codes and ordinances. If in doubt, call
a licensed electrician.
3. DO NOT modify the plug you’ve in-
stalled on this appliance. If it will not fit
the outlet, have a proper outlet installed
by a qualified electrician.
For a permanently connected dryer:
The dryer MUST be connected to a
grounded metal, permanent wiring system;
or an equipment grounding conductor
must be run with the circuit conductors
and connected to the equipment-grounding terminal or lead on the appliance.
NOTE
Dryers operating on 208 volt power supply
will have longer drying times than dryers
operating on 240 volt power supply.
Installation Instructions
13
Grounding requirements -
Electric dryer (Canada)
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
For a grounded, cord-connected
dryer:
1. The dryer MUST be grounded. In the
event of a malfunction or breakdown,
grounding will reduce the risk of electrical shock by providing a path of least
resistance for electrical current.
2. Since your dryer is equipped with
a power supply cord having an
equipment-grounding conductor and
a grounding plug, the plug must be
plugged into an appropriate outlet that
is properly installed and grounded in
accordance with all local codes and
ordinances. If in doubt, call a licensed
electrician.
3. DO NOT modify the plug provided
with this appliance. If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.
Grounding requirements -
Gas dryer (USA and Canada)
1. The dryer is equipped with a threeprong (grounding) plug for your protection against shock hazard and should
be plugged directly into a properly
grounded three-prong receptacle.
2. The plug must be plugged into an
appropriate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances. If
in doubt, call a licensed electrician.
3. DO NOT modify the plug provided
with this appliance. If it will not fit the
outlet, have a proper outlet installed by
a qualified electrician.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
Grounding type wall receptacle
Do not, under
any circumstances,
cut, remove,
or bypass the
grounding prong.
Power cord with
3-prong grounded plug
14
Access
Recovery Slot
Installation Instructions
Electrical connection
(non-Canada) - 3 wire cord
3-wire receptacle
(NEMA type 10-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing could result in personal
injury or even death.
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block access cover in the lower
corner on the back of the dryer.
3. Install a UL-approved strain relief
according to the power cord/strain
relief manufacturer’s instructions in the
power cord entry hole below the access panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA
10-30 type SRDT, through the strain
relief.
5. Attach the power cord neutral (center
wire) conductor to the SILVER colored
center terminal on the terminal block.
Tighten the screw securely.
6. Attach the remaining two power cord
outer conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the
internal ground from the center terminal
back to the GREEN screw next to the
terminal block.
NEMA 10-30
If a terminal screw falls during cord
installation, it can be retrieved in the
terminal screw recovery slot below the
access panel.
DO NOT remove
internal ground in
a 3-wire system!!
IMPORTANT
30 AMP
Cover Screw
Terminal
Block
Line 2
(BRASS Terminal)
Neutral
(SILVER Terminal)
Line 1
(BRASS Terminal)
Internal Ground
(GREEN Screw)
Install UL-Approved
Strain Relief Here
Terminal Screw
NOTE
Neutral
(center wire)
Neutral
terminal
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp
wiring/conductor at connections.
7. Follow manufacturer’s guidelines for
8. Reinstall the terminal block cover.
firmly securing the strain relief and
power cord.
Installation Instructions
Access
Recovery Slot
15
Electrical connection
(non-Canada) - 4 wire cord
4-wire receptacle
(NEMA type 14-30R)
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing could result in personal
injury or even death.
WARNING
ELECTRICAL HAZARD
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation. Verify
proper operation after servicing.
1. Turn off power supply to outlet.
2. Remove the screw securing the terminal block access cover in the lower
corner on the back of the dryer.
3. Install a UL-approved strain relief
according to the power cord/strain
relief manufacturer’s instructions in the
power cord entry hole below the access panel. At this time, the strain relief
should be loosely in place.
4. Thread an UNPLUGGED, UL-approved, 30 amp. power cord, NEMA
14-30 type DRT or SRDT, through the
strain relief.
5. Disconnect the internal (WHITE) dryer
harness ground wire from the (GREEN)
ground screw next to terminal block.
6. Attach the ground (GREEN) power
cord wire to the cabinet with the
ground (GREEN) screw. Tighten the
screw securely.
7. Move the internal dryer harness ground
(WHITE) wire to the terminal block and
attach it along with the neutral (WHITE)
power cord wire conductor to center,
SILVER colored terminal on the terminal
block. Tighten the screw securely.
8. Attach the RED and BLACK power
cord conductors to the outer, BRASS
colored terminals on the terminal block.
Tighten both screws securely.
WARNING
ELECTRICAL SHOCK HAZARD
DO NOT make a sharp bend or crimp
wiring/conductor at connections.
9. Follow manufacturer’s guidelines for
firmly securing the strain relief and
power cord.
10. Reinstall the terminal block cover.
Neutral
(WHITE
wire)
Cover Screw
Terminal
Block
Line 2
(BRASS Terminal)
Neutral
(SILVER Terminal)
Line 1
(BRASS Terminal)
Internal Ground
(GREEN Screw)
Install UL-Approved
Strain Relief Here
Terminal Screw
30 AMP
NEMA 14-30
Ground
(GREEN
wire)
NOTE
If a terminal screw falls during cord installation, it can be retrieved in the terminal
screw recovery slot below the access
panel.
Move internal ground (WHITE)
wire to neutral (SILVER)
terminal for 4-wire system.
GREEN
ground screw
GREEN
ground wire
BLACK or
RED power wire
Neutral
terminal
WHITE
neutral wire
BLACK
or RED
power wire
16
Installation Instructions
Gas connection
1. Remove the shipping cap from gas
pipe at the rear of the dryer.
IMPORTANT
DO NOT connect the dryer to L.P. gas
service without converting the gas valve.
An L.P. conversion kit must be installed
by a qualified gas technician.
2. Connect a 1/2 inch (1.27 cm) I.D.
semi-rigid or approved pipe from gas
supply line to the 3/8 inch (0.96 cm)
pipe located on the back of the dryer.
Use a 1/2 inch to 3/8 inch (1.27 cm to
0.96 cm) reducer for the connection.
Apply an approved thread sealer that is
resistant to the corrosive action of liquefied gases on all pipe connections.
Manual
Shutoff
Valve
Open
All connections must be wrench-tightened
3. Open the shutoff valve in the gas supply line to allow gas to flow through
the pipe. Wait a few minutes for gas to
move through the gas line.
Closed
Flare
Union
Nipple
GAS FLOW
Flexible
Connector
Flare
Union
Inlet Pipe on
Back of Dryer
IMPORTANT
The supply line must be equipped with an
approved manual shutoff valve. This valve
should be located in the same room as
the dryer and should be in a location that
allows ease of opening and closing. DO NOT block access to the gas shutoff valve.
WARNING
EXPLOSION HAZARD
NEVER test for gas leaks with an open
flame.
IMPORTANT
Installation to the gas service must follow
local codes and ordinances and the latest edition of the National Fuel Gas Code
ANSI Z223.1/NFPA 54 or in Canada,
CSA B149.1.
Water connection
(Steam Model only)
WARNING
Periodically inspect all water inlet hoses
for water leaks, wear, cuts, corrosion
and bulges. Replace all hoses, if any
sign of the above is visible. All hoses
should be replaced every 5 years to
reduce the risk of hose failures.
Water Supply Requirements
Cold water faucet MUST be installed within
42 inches (107 cm) of your dryer’s water
inlet. The faucet MUST be 3/4 inch (1.9 cm)
with threading for laundry hose connection.
Water pressure MUST be between 20 and
120 psi. Your water department can advise
you of your water pressure.
1. Turn off COLD water supply to washer.
to dryer
from gas supply
Shutoff Valve - Open position
4. Check for gas system leaks with a manometer. If a manometer is not available, test all connections by brushing
on a soapy water solution.
2. Remove COLD inlet hose from COLD
water supply and inspect for rubber
washer. Replace washer if it is torn or
worn out.
Rubber Washers
MUST BE PRESENT
Installation Instructions
to Washer
17
Water connection, continued
(Steam Model only)
Rubber Washer
Must be Present
and Undamaged
Cold Inlet Hose
3. Momentarily turn on COLD supply
and run some water into a bucket or
container to clear any contaminants in
the line.
4. Inspect hose couplings for proper
placement of rubber washers. Use
hoses from
5304495002 (not included).
ASSEMBLY HOSE KIT
5. If your installation has room for the
COLD water supply to accept the “Y”
connector directly, thread the “Y” connector to the COLD water supply and
snug it by hand; then tighten it another
2/3 turn with pliers.
NOTE
If you were able to install the “Y” connector directly to the COLD water supply,
please skip to step 8.
6. If there is not room to install the “Y”
connector directly, thread the short
extension hose on to the COLD water
supply and snug it by hand; then
tighten it another 2/3 turn with pliers.
7. Thread the “Y” connector to the short
extension hose and snug it by hand;
then tighten it another 2/3 turn with
pliers.
8. Connect the COLD inlet hose for the
washer to the “Y” connector and snug
it by hand; then tighten it another 2/3
turn with pliers.
9. Connect the straight end of the long
#
hose from the kit to the other outlet
on the “Y” connector and snug it by
hand. Connect the hose’s 90° coupling to the brass water inlet on the
back of the dryer and snug it by hand.
Tighten each connection of the dryer
inlet hose another 2/3 turn with pliers.
Hose Extension
“Y” Connector
Cold Water Supply
Hose to Washer
Water Inlet
on Dryer
10. Turn on the water and check for leaks
at all connections.
18
Installation Instructions
General installation
1. Connect the exhaust duct to the outside exhaust system. Use of a 4” (102
mm) clamp (item A) is recommended to
connect the dryer to the exhaust vent
system. Use metal foil tape to seal all
other joints.
2. Use a carpenter’s level to level your
dryer front-to-back and side-to-side.
3. Use adjustable pliers to adjust the
leveling legs so the dryer is level frontto-rear and side-to-side, and stable
corner-to-corner.
4. Press down on alternate corners and
sides and feel for the slightest movement. Adjust the appropriate leg(s) so
the dryer sits solidly on the floor on
ALL four legs. Keep the leveling leg
extension at a minimum for best performance of the dryer.
IMPORTANT
Be sure the power is off at a circuit
breaker/fuse box before plugging the
power cord into an outlet.
5. Plug the power cord into a grounded
outlet.
WARNING
Improper grounding of the dryer may
cause serious injury or death. Check with
a licensed electrician if you are in doubt
as to whether the appliance is properly
grounded.
6. Turn on the power at the circuit
breaker/fuse box.
7. Read the Use & Care Guide provided
with the dryer. It contains valuable and
helpful information that will save you
time and money.
8. If you have any questions during initial
operation, please review the “Avoid
Service Checklist” in your Use & Care
Guide before calling for service.
9. Place these instructions in a location
near the dryer for future reference.
NOTE
A wiring diagram and technical data
sheet are located under the dryer top
panel.
CAUTION
When discarding or storing your old dryer, remove the door.
Reversing Door
x2
x2
NOTE
Door reversibility is available on all dryer models.
IMPORTANT
BEFORE YOU REVERSE YOUR DRYER
DOOR:
1. Be sure you have adequate swing area
before reversing door.
2. Gather your tools - including a screw
driver with a #2 square bit and plastic
knife (or small, flat prying tool that won’t
damage paint).
3. Be sure dryer is unplugged from power
source!
WARNING
ELECTRICAL SHOCK HAZARD
Failure to disconnect power source before servicing could result in personal injury or
even death.
Tools needed for reversal:
Plastic knife
Screwdriver
with #2
square bit
19
Removing Latch and Hole Plugs
1. Open the door.
2. Remove plastic hole plugs and save to
reinstall later. You may have to use a
non-scratching plastic knife if you are
unable to dislodge the plugs manually.
3. Remove both screws from door latch.
Save latch and screws for reinstallation
later.
20
x2
x4
Reversing Door
Removing Door Assembly
1. Completely open the door to expose all
four hinge screws.
2. Remove all four hinge screws with #2
square bit driver. Save for reinstalling
later.
x4
3. Grasp the door with both hands and
lift slightly as you pull door and hinge
away from the front panel.
Reinstalling Door Assembly
1. Rotate the door and hang the upper
hook on the back of the hinge in the
upper hole of the front panel.
Reinstalling Latch and Hole Plugs
1. Install door latch with screws removed
earlier.
2. Insert plastic hole plugs removed
earlier.
x2
2. Reinstall and tighten all four screws
removed earlier - two front screws first,
then two side screws.
1
3
4
2
Verify Reversed Door Operation
1. Test door for free, smooth swinging
operation and secure latching when
closed.
2. Plug in dryer and close the door. Start
a test cycle: drum should tumble until
door is pulled open or cycle is paused
or canceled.
Options
(67 cm)
21
Accessories
MATCHING STORAGE PEDESTAL*
White Pedestal - P/N EPWD257UIW
Titanium Pedestal - P/N EPWD257UTT
A storage pedestal accessory, specifically designed for this dryer may be
used to elevate the dryer for ease of
use. This pedestal will add about 15”
(38 cm) to the height of your unit.
*Other colors may be available. Contact the
source where you purchased your dryer.
DRYER STACKING KIT
P/N STACKIT7X
Depending on the model you purchased, a kit for stacking a matching
dryer on top of this washer may have
been included in the initial purchase of
your dryer. If your model did not include
a stacking kit or you desire another
stacking kit, you may order one.
LP CONVERSION KIT
P/N PCK4200
Gas dryers intended for use in a location supplied with LP must use a conversion kit prior to installation.
MOBILE HOME INSTALLATION KIT
P/N 137067200
Installations in mobile homes require
use of MOBILE HOME INSTALLATION
KIT.
DRYING RACK
P/N A04840701
Depending on the model you purchased, a drying rack may have been
included in the initial purchase of your
dryer. If your model did not include a
drying rack or you desire another drying rack, you may order one.
UNIVERSAL APPLIANCE WRENCH
P/N 137019200
A UNIVERSAL APPLIANCE WRENCH
is available to aid in dryer/washer/pedestal feet adjustment.
TOUCH UP PAINT PENS
White - P/N 5304468812
Titanium - P/N 5304475700
*Other colors may be available. Contact the
source where you purchased your dryer.
ASSEMBLY HOSE KIT
P/N 5304495002
WARNING
Failure to use accessories manufactured
by (or approved by) the manufacturer
could result in personal injury, property
damage or damage to the dryer.
27”
(68.5 cm)
15”
(38 cm)
26.5”
Storage Pedestal
Drying Rack
Universal Appliance Wrench
Replacement parts in
U.S. and Canada
If replacements parts are needed for
your dryer, you can contact the source
where you purchased your dryer, call
1-877-4ELECTROLUX (1-877-435-
3287) in the U.S. or 1-800-265-8352
in Canada, or visit our website,
www.electroluxappliances.com in the U.S.
or www.electroluxappliances.ca in Canada
for the Electrolux Authorized Parts Distributor nearest you.