Electrolux C-Flex 1200 User Manual

Page 1
PROFESSIONAL LAUNDRY
C-Flex 900, 1200
Features and benefits
• Chest type industrial ironer with mobile chest and fixed roll, offering a constant pressure and a maximum ironing surface for the utmost ironing quality
• Steam or thermal fluid heating
• The unique design of the chest and roll combined with an improved thermal insulation give a thermal output close to 97%
• Up to three chest can be mounted together for a 50m/min maximum ironing speed
• Simple and reliable drive, possible thanks to the fixed roll technology
• One adjustable suction fan per roll for an improved vapor suction
• Springpress contact and an optimized vapor extraction
®
fitting for an optimum roll and chest
Main specifications
Max. water evaporation* l/h Cylinder number
diameter mm length mm
Ironing speed** m/min
Main options
• Stainless steel Springpress® fitting for an extended longevity
• Nomex padding withstand temperatures above 180°C
• Extra insulation of the casings for a lower energy consumption and an improved working environment
• Vacuum feeding table for an easier use
• Preset ironing speeds or special speed ranges to customize the ironing to the user specificities
• Connection with feeding and folding systems
C-Flex 900 C-Flex 1200
205-795 210-1260 1-3 1-3
900 1200 2700, 3000, 3300, 3500 3000, 3300, 3500, 4200
4-51 6-51
Heating steam consumption*** kg/h
* 12 bars steam heating, smallest – biggest machine and 100% cylinder use, see detailed data ** See detailed data for available speed ranges per dimension *** 12 bar steam heating, smallest – biggest machine, see detailed data
240-960 295-1530
Page 2
Electrical connections
Voltage 400-415V 3AC 50Hz – 1 roll kW 400-415V 3AC 50Hz – 2 rolls kW 400-415V 3AC 50Hz – 3 rolls kW
927 930 933 935
4.6
12 22
Steam and air connections
Max. steam pressure kPa Compressed air DN
1400 15
1 roll
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
32 25 200
3
/h
2000
2 rolls
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
40 32 2 x 200
3
/h
2 x 2000
3 rolls
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
50 40 3 x 200
3
/h
3 x 2000
Sound level
Airborne sound level dB(A)
66
Heat emission
% of installed power, standard insulation % of installed power, extra insulation
5 3
Performances and energy consumption
1 roll
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
205 225 250 265 240 270 300 320 330 370 410 435 5-15
2 rolls
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
410 450 500 530 480 540 600 640 660 740 820 870 9-27
3 rolls
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
615 675 750 795 720 810 900 960 940 1110 1230 1305 14-42
Dimensions
A width mm B ironing width mm
C length 1 roll mm C length 2 rolls mm C length 3 rolls mm
D height mm
3900 4200 4500 4700 2700 3000 3300 3500
1685 2955 4225
1560
Net weight
1 roll kg 2 rolls kg 3 rolls kg
* 50% residual moisture, 140 gr/m2 polyester-cotton linen, 100% cylinder use ** Other speed range available on request
3010 3200 3400 3530 5980 6360 6760 7030 8950 9550 10170 10600
Page 3
Electrical connections
Voltage 400-415V 3AC 50Hz – 1 roll kW 400-415V 3AC 50Hz – 2 rolls kW 400-415V 3AC 50Hz – 3 rolls kW
1230 1233 1235 1242
7.9
19.6 30
Steam and air connections
Max. steam pressure kPa Compressed air DN
1400 15
1 roll
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
40 32 200
3
/h
2000
2 rolls
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
50 40 2 x 200
3
/h
2 x 2000
3 rolls
Steam DN Condensate DN Exhaust dia. (K) mm Evacuated air m
65 50 3 x 200
3
/h
3 x 2000
Sound level
Airborne sound level dB(A)
66
Heat emission
% of installed power, standard insulation % of installed power, extra insulation
5 3
Performances and energy consumption
1 roll
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
300 330 350 420 360 395 420 510 500 550 585 710 8-24
2 rolls
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
600 660 700 840 720 790 840 1020 1000 1100 1170 1420 14-43
3 rolls
Max. water evaporation (14 bar) l/h Steam average consumption (12 bar) kg/h Average linen output (12 bar)* kg/h Ironing speed** m/min
900 990 1050 1260 1080 1185 1260 1530 1500 1650 1755 2130 14-43
Dimensions
A width mm B ironing width mm
C length 1 roll mm C length 2 rolls mm C length 3 rolls mm
D height mm
4200 4500 4700 5400 3000 3300 3500 4200
1985 3555 5125
176 0
Net weight
1 roll kg 2 rolls kg 3 rolls kg
* 50% residual moisture, 140 gr/m2 polyester-cotton linen, 100% cylinder use ** Other speed range available on request
3860 4100 4360 4820 7700 8200 8530 9700 11630 12400 12900 14650
Page 4
2
1
6
5
5
5
5
x = 1 - 40 mm
1
2
6
3
4
B
A
7303
Top view
4
1
x
2
6
7302
Side view
3
D
2 Steam inlet 3 Electric connection
www.electrolux.com/professional
Share more of our thinking at www.electrolux.com
1 Compressed air inlet
7301
Rear view
4 Main switch 5 Vapor exhaust 6 Condensate connection
Art. No. 438918621/2015.01.14
We reserve the right to alter specifications without notice.
Loading...