Page 1/4
Identification:
Tech. Bulletin n°:
Date:
Issuer:
Factory:
Subject
Model
Problem
A14 - N900
PDX2005-02
26-05-2005
M. Scalon (TT&S)
PD-Vallenoncello Modular Cooking
N900 PASTA COOKERS: NEW WATER
SOLENOID VALVE
200372, 200373, 200374, 200375, 200376, 200377,
200378, 200379, 200380, 200381, 200382, 200383,
200396, 200397, 200398, 200399, 200400, 210376,
210377, 210378, 210379, 210380, 210381, 210382,
210383, 220376, 220377, 220378, 220379, 220380,
220381, 220382, 220383, 224009
The solenoid breaks in case of:
- lack of water in the main water supply net;
- hot water supplied to the pasta cooker.
Reason
Actions in
factory
Actions in
field
- The solenoid is designed for intermittent duty.
- New components from s/n 521…
- Updated the spare part lists.
- New components to install:
1. Water solenoid valve (new code: 0C2390);
2. n°2 hose carriers (code: 0C1626) for inner
water connections;
The new components are available as spare part.
The present modification can be retrofitted but it is not mandatory
For the spare part code of each component see also the Spare
Parts Catalogue.
ELECTROLUX PROFESSIONAL SPA TELEPHONE TELEFAX E-MAIL ADDRESS
POSTAL ADDRESS +39 0434 380582 +39 0434 380577 claudio.marziani@electrolux.it
V.le Treviso 15 +39 0434 380583 mara.scalon@electolux.it
33170 PORDENONE – ITALIA
Page 2/4
Tech. Bulletin PDX2005-02
OLD WATER SOLENOID VALVE NEW WATER SOLENOID VALVE
Solenoid ‘class F’
Room temperature 80 °C
Body in brass
To replace the new water solenoid valve on equipments older than s/n 521…
it is needed to run also the following modifications:
9 Bottom: it is needed to drill 2 holes (diam. 6 mm) for fitting the valve
round the main water inlet hole (see picture below);
16.5
Φ 5
31°
10
26
16
Φ 30
water inlet hole
17°
2 holes to drill: diameter 6 mm