Identification:
Technical Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
Action in Factory
Action in Field
C08
PDD2005-04
16 February 2005
F. Fingolo (Ovens Customer Support Dept.)
PDD Vallenoncello - Italy
AOS NEW ANTIREFLOW VALVES
All AOS range, levelA
Need of semplifying the Cleaning System
Substituted old antireflow valves with new ones in new position from
serial number 506 (no retrofit)
h
NEW ANTIREFLOW VALVE
are part code 0C2312
S
OLD ANTIREFLOW VALVE
are part code 007008
S
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15
33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15
33170 PORDENONE - ITALY
++39 0434 380528 www.electrolux.com 00072220932
++39 0434 380555 filippo.fingolo@electrolux.it
Eliminated antireflow valves and pipes connecting boiler and cleaning system to
steam condenser draining tube.
EW POSITION
FOR
ANTIREFLOW
LEANING SYSTEM
LD CLEANING SYSTEM
Now are used two new antireflow valves for cleaning system water connection and
two for boiler water connection, put directly on nipples.
2