Identification:
Technical Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
Action in Factory
Action in Field
C08
PDD2005-06
30 March 2005
F. Ornella (Ovens Customer Support Dept.)
PDD Vallenoncello - Italy
BOILER BURNER FOR AOS061G, AOS101G,
AOS102G, AOS202G
AOS061G, AOS101G, AOS102G, AOS202G
Delayed ignition
Too high distance between ignition and ground rod
Changed burner and ignition rod from SN 432. All the ovens in
wharehouse were reworked.
The new burner is interchangeable with the old one.
In particular the spare part codes are:
Burner for AOS061G, AOS101G, AOS102G: 0C1865
Burner for AOS202G: 0C2190
Ignition rod: 0C2189 (AOS061G, AOS101G models)
Ignition rod: 0C1866 (AOS102G models)
Ignition rod: 0C2191 (AOS202G models – 2 pieces)
Detection rod: 0C1068 (all models)
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15
33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15
33170 PORDENONE - ITALY
++39 0434 380528 www.electrolux.com 00072220932
++39 0434 380555 filippo.fingolo@electrolux.it