Subject

Model Problem Reason Action in Factory
Action in Field
C08
PDD2005-06

BOILER BURNER FOR AOS061G, AOS101G, AOS102G, AOS202G

AOS061G, AOS101G, AOS102G, AOS202G Delayed ignition Too high distance between ignition and ground rod Changed burner and ignition rod from SN 432. All the ovens in
wharehouse were reworked. The new burner is interchangeable with the old one.
In particular the spare part codes are: Burner for AOS061G, AOS101G, AOS102G: 0C1865 Burner for AOS202G: 0C2190 Ignition rod: 0C2189 (AOS061G, AOS101G models) Ignition rod: 0C1866 (AOS102G models) Ignition rod: 0C2191 (AOS202G models – 2 pieces) Detection rod: 0C1068 (all models)
ELECTROLUX PROFESSIONAL SPA MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15 33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15 33170 PORDENONE - ITALY
++39 0434 380528 www.electrolux.com 00072220932
++39 0434 380555 filippo.fingolo@electrolux.it
GROUND ROD
DETECTION ROD
IGNITI ON ROD