Technical Bulletin
Identification:
Bulletin no:
Date:
Issuer:
Factory:
Subject:
E01-02-03-06-07-09
VTX2005-01
03-03-05
Customer Support Dept.
Villotta (Italy)
How to change parameters values into °F
Model:
Problem:
Reason:
Action in
All Cabinets and Counters with electronic board,
Self-Service units and Blast Chiller and Freezer.
The display shows temperatures in °C, or parameters need
to be adjusted.
The standard values of the factory parameters of the spare
part main board are in °C.
Factory:
Action in
Field:
The service should be able to reset the factory parameters
quickly, changing from °C to °F.
When resetting the factory parameters from °C to °F you don’t have to change all the parameters, but
FIRST you must reset the parameter related to the temperature unit of measure:
• Cabinets, Counters and Self-Service: “UNI” from C to F;
• Blast Chiller & Freezer “Dro” from C to F.
Then you can check all the factory parameters according to the parameters map (if available in °F).