Identification:
Technical Bulletin no:
Date:
Issuer:
Factory:
Subject
Model
Problem
Reason
Action in Factory
Action in Field
C08
PDD2005-16
04 October 2005
A. Canova (Ovens Customer Support Dept.)
PDD Vallenoncello - Italy
Cavity burner detection rod on AOS gas ovens
All AOS gas ovens
Detection problems.
Bending of the detection rod.
Introduced of a new detection rod 20 mm shorter; from SN 522.
The new rod is completely interchangeable with the old one and has the
same spare part code: 0C1049. The stock in spare part warehouse was
updated.
OLD: 100 mm
NEW: 80 mm
ELECTROLUX PROFESSIONAL SPA
MAILING ADDRESS TELEPHONE WEBSITE VAT NO.
VIALE TREVISO, 15
33170 PORDENONE - ITALY
OFFICE ADDRESS TELEFAX E-MAIL ADDRESS
VIALE TREVISO, 15
33170 PORDENONE - ITALY
++39 0434 380516 www.electrolux.com 00072220932
++39 0434 380555 alessandro.canova@electrolux.it