Electrolux 727151, AOCP201CRR, AOCP061T User Manual

Electrolux air-o-chill
Blast Chillers 100 kg - 20 GN 1/1
Chilling means bringing the temperature of cooked food from +90ºC to +3°C in a short time lap which does not allow bacterial growth .Electrolux Blast Chillers reduce temperature from +90ºC to +3°C at food core in less than 90 minutes: the model detailed on this sheet performs this cycle up to a 100 kg full load. After the Blast Chilling a holding cycle starts automatically to maintain food at +3°C. Blast chilled food has a solid 5 days shelf life without loss of flavour, nutritional values and weight. The opportunity to prepare in a single shot the food to be used in different times during the week enables a better work scheduling and therefore a sensible reduction in labour costs.
OPERATING MODES
Cruise: the chiller automatically sets
the parameters for the quickes and best chilling (it works by probe).
Soft Chilling (Air temperature –2°C).
Hard Chilling (Air temperature
–20°C).
All the probe-driven cycles feature
ARTE (Algorithm for Remaining Time Estimation) to make planning the activities easier.
Holding at +3°C (automatically
activated at the end of each cycle).
Turbo cooling: the chiller works
continuously at the desired temperature. Ideal for continuous production.
It is possible to operate by time or
by probe.
The control unit provides several
operating settings: time/core temperature according to NF and UK regulations, time/air temperature/probe personalised according to national regulations, sterilizing cycle: UV lamps built-in (on request), 3 single sensor core temperature probes (as accessory), ideal for meats, automatic defrosting and manual defrosting. All parameters are programmable.
3-sensor core probe as standard.
The control unit provides two large
displays to read out: time, core temperature, cycle countdown, alarms, service information.
Two customizable cycles (P1 & P2)
for each operating mode, allowing to set the time and air temperature. These programs can be converted into ice-cream specialized cycles (shape maintainance and holding).
All information related to the
different operating models are recorded: date, time, cycle, core temperature, holding temperature, HACCP accordance.
An audible alarm starts when the
cycle ends or terminates abnormally.
PERFORMANCE
Blast Chilling cycle: 100 kg from
+90°C up to + 3°C in less than 90 minutes.
Chilling times can vary according to
food quantity, density, moisture contents and type of containers. Chilling capacity according to NF* regulations is 70 kg.
Electrolux air-o-chill
Blast Chillers 100 kg - 20 GN 1/1
CONSTRUCTION
Model AOCP061T available for
tower configuration (with a six grids air-o-steam oven).
Internal and external finishing in 304
AISI stainless steel and back panel in stainless steel.
High density polyurethane
insulation, 60 mm tickness, HCFC free.
Environmentally friendly: R404a as
refrigerant fluid.
Developed and produced in ISO
9001 and ISO 14001 certified factory.
Inner cell with fully rounded corners.
Door equipped with removable
magnetic gasket with hygienic design.
Motors and fan waterproof
protected IP20.
Evaporator with antirust protection.
Ventilator (fan) swinging hinged
panel for access to the evaporator for cleaning.
Automatic heated door frame.
Solenoid valves.
1 thermostatic expansion valve.
Feet 200 mm high.
Stand alone printer as optional, built
in on request.
PC connection on request, gate RS
485.  INSTALLATION
No water connections required.
Waste water can be plumbed into
drain, but can also be collected in an optional waste container.
MOBILE RACK
Model AOCP061 is compatible with
air-o-steam and air-o-cook ranges.  *NF HYGIENE ALIMENTAIRE certifying authority : AFAQ AFNOR CERTIFICATION. Adress:11, Avenue Francis de Pressense - 93571 Saint-Denis La Plaine Cedex - France. Conformity with regulation NF031. Certified guarantees: fitness for cleaning, thermal performance.  Installation diagram:  C - Water drain I - Electrical connection Y - Connection for appliance lifting L - Remote electrical connection N - Cooling water inlet O - Cooling water outlet
AOCP201CRR
TECHNICAL DATA
Type Blast Chiller - 100 kg Productivity per cycle - kg. NF Regulations - chilling / freezing 72 UK Guide lines - chilling / freezing 100 Cooling unit Remote Thermostat Electronic Thermometers Digital External dimensions - mm width 1040 depth/with open doors 895 height 1783 N° and type of door 1 Door hinges Left Trays type GN 1/1; 600x400 Max load capacity - trays h 65 mm - n° 20 N° defrost in 24 hrs. 6 Refrigerant type R404a Refrigeration power - W 13480 Refrigerant power at evaporation temperature - °C -10 Power - kW installed-electric 0.88
INCLUDED ACCESSORIES
3-SENSOR PROBE FOR CHILLER+C/FREEZER 1
ACCESSORIES
1 SINGLE SENSOR PROBE CHILLER+C/FREEZER 880089 2 SINGLE SENSOR PROBES CHILLER+C/FREEZER 880096 AIR REMOTE UNIT CHILL+C/FREEZER CW 100KG 880031 AIR/WATER REMOTE UNIT F.BC+BCF LW 100KG 880059 BANQ.TROLLEY-45PLATES-85MM PITCH-20GN1/1 922072 BANQ.TROLLEY-54PLATES-74MM PITCH-20GN1/1 922016 KIT 3 SINGLE SENSOR PROBES FOR BC/BCF 880269 KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW 880183 KIT HACCP EKIS 922166 PAIR OF 1/1 GN AISI 304 S/S GRIDS 921101 PASTRY TROLLEY 16(400X600)80MM-20 1/1 LW 922068 PRINTER FOR HACCP BASIC VERSION 881532 RILSAN COATED GRID 881061 THERMAL COVER FOR 20X1/1GN 922014 TROLLEY TRAY RACK F. 20X1/1GN,63MM PITCH 922007 TROLLEY TRAY RACK F.16X1/1GN,80MM PITCH 922010 WATER REMOTE UNIT BLAST CHILLER CW 100KG 880034
727151