Eldes ESIM4, ESIM4Q User Manual

ESIM4 ESIM4 Q
Battery Powered GSM Auto Dialler/ Mini Alarm System
User Manual v1.5
SAFETY INSTRUCTIONS
Please read and follow these safety guidelines in order to maintain safety of operators and people around:
• Battery powered GSM auto dialler/mini alarm system ESIM4/ESIM4 Q (later referenced as “the system”, “the device” or “ESIM4”) is equipped with a radio trans ceiver operating in GSM900/1800 bands / GSM850/900/1800/1900 bands respectively.
• DO NOT use the system where it can cause potential danger and interfere with other devices – such as medical devices.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impact.
• DO NOT attempt to repair the system yourself – any repairs must be carried out by fully qualied personnel only.
ESIM4 is a device that must be installed in limited access areas. Any system repairs must be done only by qualied, safety aware personnel.
Remove all batteries before installing. Never install or carry out maintenance during stormy weather.
The system must be powered by four 1,5 V lithium AA type batteries only. When inserting the batteries into the battery slots, mind the polarity terminals! Any additional device you connect to the system, such as a computer, must be powered by an EN 60950-1 approved supply.
To switch the system o, remove all four 1,5 V lithium AA type batteries.
Fuse F1 model – miniSMDC 0,5A. Replacement fuses have to be exactly the same as indicated by the manufacturer.
If you use a computer for the device conguration, it must be earthed.
The WEEE (Waste Electrical and Electronic Equipment) symbol on this product (see left) means it must not be disposed of in household waste. To prevent possible harm to human health and/or the environment, you must dispose of this product in an approved and environmentally safe recycling facility. For further information contact your system supplier, or your local waste authority.
2
2 EN
ESIM4 Manual v1.5
CONTENTS
1. GENERAL INFORMATION ...........................................................................................................................................................6
2. TECHNICAL SPECIFICATIONS ....................................................................................................................................................6
2.1. Electrical and Mechanical Characteristics .....................................................................................................................................................6
2.2. Main Unit and LED and Connector Functionality .........................................................................................................................................7
2.3. Wiring Diagrams ................................................................................................................................................................................................8
3. INSTALLATION ...........................................................................................................................................................................9
4. GENERAL OPERATIONAL DESCRIPTION..................................................................................................................................10
5. CONFIGURATION METHODS ....................................................................................................................................................10
5.1. SMS Text Messages .........................................................................................................................................................................................10
5.2. ELDES Conguration Tool ..............................................................................................................................................................................10
5.3. QR Codes ...........................................................................................................................................................................................................11
6. SMS PASSWORD .......................................................................................................................................................................11
7. USER PHONE NUMBERS ..........................................................................................................................................................12
8. DATE AND TIME........................................................................................................................................................................13
8.1. Automatic Date and Time Synchronization ................................................................................................................................................13
9. SLEEP AND WAKE-UP MODES .................................................................................................................................................14
9.1. Wake-Up Scheduler ........................................................................................................................................................................................15
10. INPUTS ....................................................................................................................................................................................16
10.1. Input Z1 ..........................................................................................................................................................................................................16
10.1.1. Digital Mode ...................................................................................................................................................................................................17
10.1.2. Analog Mode ..................................................................................................................................................................................................18
10.1.3. AUX Output ....................................................................................................................................................................................................18
10.2. Input Z2 ..........................................................................................................................................................................................................19
10.2.1. Digital Mode .................................................................................................................................................................................................. 20
10.2.2. Temperature Sensor Mode .........................................................................................................................................................................21
10.2.3. iButton Key Mode .........................................................................................................................................................................................23
10.3. Alarm/Restore Notications ...................................................................................................................................................................... 24
10.3.1. Alarm Delay ................................................................................................................................................................................................... 26
11. SHOCK SENSOR .......................................................................................................................................................................27
12. ALARM/RESTORE NOTIFICATION SCHEDULER ..................................................................................................................... 28
13. OUTPUT ................................................................................................................................................................................. 29
13.1. Output Name ................................................................................................................................................................................................... 29
13.2. Turning Output ON and OFF ......................................................................................................................................................................... 29
14. BATTERY LEVEL MONITORING ...............................................................................................................................................32
15. ARMING AND DISARMING .......................................................................................................................................................33
16. SYSTEM INFORMATION. STATUS SMS ................................................................................................................................... 34
16.1. Periodic Status SMS .......................................................................................................................................................................................34
17. SYSTEM NOTIFICATIONS ........................................................................................................................................................35
18. EVENT MEMORY .....................................................................................................................................................................37
19. REMOTE LISTENING ............................................................................................................................................................... 38
20. TECHNICAL SUPPORT ........................................................................................................................................................... 39
20.1. Troubleshooting ............................................................................................................................................................................................. 39
20.2. Restoring Default Parameters ..................................................................................................................................................................... 39
20.3. Updating the Firmware via USB Cable ........................................................................................................................................................ 39
21. RELATED PRODUCTS .............................................................................................................................................................40
ESIM4 Manual v1.5
3
3EN
Limited Liability
The buyer agrees that the system will reduce the risk of re, theft, burglary or other danger but that it does not guarantee against the oc­currence of such events. “ELDES UAB” will not take any responsibility for the loss of personal eects, property or revenue whilst using the system. The liability of “ELDES UAB” is limited to the value of the system purchased. “ELDES UAB” is not aliated with any mobile/wireless/ cellular provider and is therefore not responsible for the quality of such services.
Manufacturer Warranty
The system carries a 24-month manufacturer warranty from “ELDES UAB”. The warranty begins the day the system is purchased by the user and the receipt must be retained as proof of purchase date. The warranty remains valid only if the system is used as intended, fol­lowing all guidelines outlined in this manual and in accordance with the operating conditions specied. The warranty is void if the system has been exposed to mechanical impact, chemicals, high humidity, uids, corrosive and hazardous environments or force majeure factors.
Dear Customer,
Thank you for choosing to purchase the battery powered GSM dialler ESIM4. Your thoughtful decision will ensure reliable solution for many years as all ELDES products are manufactured to meet the highest standards.
We are condent that you will be completely satised with your product. However, in the unlikely event that you do experience a problem, please contact the dealer from whom you made your purchase.
UAB ELDES
www.eldes.lt
Contents of Pack
Item Quantity
ESIM4 ...........................................................1
User manual. ...............................................1
1,5 V Lithium AA batteries........................4
GSM antenna... ............................................1
Plastic gland.... ............................................1
Screws. ........................................................2
Terminal block... .........................................1
Not included:
• SIM card – we recommend you get a contract SIM, not Pay As You Go.
• miniUSB cable - can be obtained from your local distributor.
• Temperature sensor - can be obtained from your local distributor.
• Microphone - can be obtained from your local distributor
• iButton key reader- can be obtained from your local distributor
• iButton keys - can be obtained from your local distributor
• Buzzer - can be obtained from your local distributor
4
4 EN
ESIM4 Manual v1.5
Copyright © “ELDES UAB”, 2015. All rights reserved
It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, “ELDES UAB” declares that the battery pow­ered GSM auto dialler/mini alarm system ESIM4 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt.
ESIM4 Manual v1.5
5
5EN
1. GENERAL INFORMATION
OUT
ESIM4 is a micro-controller based device used to inform users about the alarm in automatic or security systems, supply power to an auxiliary device and control one electrical appliance or measure temperature. The device can also be used as a mini-alarm system.
Examples of using the system:
• Suitable in areas without a 230V power supply.
• Switching one electronic device ON/OFF.
• Notication of failure or restoration of an electronic device via SMS text message and/or phone call.
• Property security.
• Temperature monitoring.
• Lighting, garden watering, water pump and other electrical equipment control via SMS text messages.
• Remote listening to what is happening in the secured area.
Main features:
• Conguration by SMS text message and PC.
• Sleep mode for battery power saving for up to 2 years.
• Up to 10 users for system conguration, control and acceptance of system event notications by SMS text messages and phone calls.
• 2 inputs on board turning to 4 inputs when ATZ mode enabled.
• Inputs Z1-Z4 customizable to NC or NO.
• Input Z1/Z3 modes: digital or analog.
• 1 AUX output operating in accordance with the set up period.
• Input Z2/Z4 modes: digital, temperature sensor or iButton key.
• Mini-alarm system: arming/disarming by iButton key.
• Up to 8 temperature sensors support for temperature monitoring in dierent areas.
• 1 open-collector output for electrical appliance control.
• Built-in shock sensor for alarm/restore notication by SMS text message on vibration detection.
• Scheduled system operation in Wake-Up mode and on system event.
• Scheduled input alarm/restore notications.
• Periodic self-test notication by SMS text message to user phone number.
• Customizable notication texts.
• QR code generator allowing to arrange a single or multiple text commands in a single SMS text message and encrypt it in a QR code.
2. TECHNICAL SPECIFICATIONS
2.1. Electrical and Mechanical Characteristics
Battery type ............................................................................................1.5 V Lithium AA type batteries
Number of batteries ..............................................................................4
Current used in Sleep mode .................................................................30µAmax
GSM modem frequency .........................................................................ESIM4 - 900/1800 Mhz; ESIM4 Q - 850/900/1800/1900 MHz
Number of inputs ...................................................................................2
Digital input value range ......................................................................0... 3000mV
Analog input value range .....................................................................0... 24mA
Impulse duration ....................................................................................>600ms
Number of auxiliary terminals .............................................................1
Auxiliary output values .........................................................................12V 200mA max
Maximum supported number of temperature sensors ...................8
Number of outputs ................................................................................1
Output circuit ..........................................................................................Open collector output.
Output current........................................................................................200mA max
Supported temperature sensor model ..............................................Maxim®/Dallas® DS18S20, DS18B20
Supported iButton key model .............................................................. Maxim®/Dallas® DS1990A
Dimensions .............................................................................................115x90x56mm (4.53x3.54x2.20in)
Enclosure rating .....................................................................................IP 65
Operating temperature range .............................................................-20…+50°C (-30...+55°C with limitations (-4... +122°F (-22... +131°F with
Humidity ..................................................................................................0-90% RH @ 0...+40°C (0-90% RH @ +32...+104°F) (non-condensing)
Output is pulled to COM when enabled.
limitations))
ATTENTON: All 4 batteries must be of the same manufacturer.
6
6 EN
1 R
ESIM4 Manual v1.5
NOTE: We recommend using Camelion P7 lithium 1.5V AA type and Energizer Ultimate lithium 1.5V AA type batteries or other ‘‘ELDES UAB’’
recommended batteries.
2.2. Main Unit and LED and Connector Functionality
1
ANT
- -
+
+
Main Unit Functionality
GSM MODEM GSM network 900/1800 MHz modem
SIM SIM card slot
LED Light-emitting diode indicator
BATTERY
GSM
MODEM
BATTERY
BATTERY
ANT GSM antenna
MIC Microphone
USB Mini USB port
DEF Button for restoring default settings
FW Pins for rmware upgrade
FW
LED
+ +
C1 Z2 Z1AUX COM
- -
SIM
USB
MICDEF
OPEN
Connectors Description
Z1 Digital input / analog input terminal
Z2 Digital input / temperature sensor or iButton data terminal (DATA)
COM Common terminal
AUX Auxiliary power supply terminal
C1 Open-collector output / temperature sensor or buzzer power
supply positive terminal (+4V)
LED indications Description
1 ash every 0.5 sec. SIM card is not present / PIN code enabled
3 quick ashes every 3 sec. Searching for GSM network
1 ash every 5 sec Connected to GSM network / system operating successfully
1 quick weak ash every 10 sec. The device is operating in Sleep mode
ESIM4 Manual v1.5
7
7EN
2.3. Wiring Diagrams
ESIM4
AUXC1 COM Z2 Z1
5,6KΩ
1KΩ2KΩ
2 3
ESIM4
AUXC1 COM
Z2 Z1
PGM2
PGM1
Alarm system or other appliance
General wiring AUX wiring
4
ESIM4
AUXC1 COM Z2 Z1
GND
DATA
DATA
+4V
+4V
DS18S20, DS18B20
Temperature sensor
GND
ESIM4
AUX
C1 COMZ2 Z1
20mA
PRESSURE
VESSEL
PRESSURE
4mA
SENSOR
Gauge pressure transmitter
5
ESIM4
AUX
C1 COMZ2 Z1
+
Electrical appliance
Power supply
Temperature sensor wiring
6
ESIM4
AUXC1 COM Z2 Z1
+ -
BUZZER
brown
white
iButton key reader
iButton key reader and buzzer wiring
8
8 EN
Output wiring
7
ESIM4
AUXC1 COMZ2 Z1
5,6KΩ
Z1
COM
Magnet
Example of input wiring in ATZ mode
1KΩ2KΩ
Z3
COM
Magnet
ESIM4 Manual v1.5
3. INSTALLATION
For the connection of input/output terminals, use 0.50 mm2(0.02in2 ) 1 thread unshielded cable of up to 100m (328.08ft) length.
1. Wire up the system in accordance with the wiring diagrams (see 2.3 Wiring Diagrams for more details).
2. If necessary to run the wires, drill out a hole of 13mm (0.51in) diameter in the ESIM4 enclosure and insert the plastic gland supplied in
ESIM4 package. The plastic gland must be facing down.
8
3. The system comes with a GSM antenna that is already connected. If another type of GSM antenna is required, please replace the
standard GSM antenna with an antenna of your choice.
4. When placing the system, follow the recommendations:
11
5. Disable the PIN code request of the SIM card by inserting it into a mobile phone and following the proper menu steps.
6. Once the PIN code is disabled, insert the SIM card into the SIM card slot / holder of ESIM4 system.
12
9
Never install in the following locations:
• inside the metal cabinet
• closer than 20cm (7.87in) from the
metal surface and/or power lines
13
10
14
15
OPEN
16
OPEN
7. Insert all 4 batteries and wait until the LED indicator starts blinking indicating successful micro-controller operation. The system is
now running in Wake-Up mode for 3 minutes to congure the system by SMS text messages (see 5. CONFIGURATION METHODS).
8. Change the default SMS password (see 6. SMS PASSWORD for more details).
9. Set the phone number for User 1 (see 7. USER PHONE NUMBERS for more details).
10. Once the LED indicator lights OFF, the system will switch to Sleep mode and it will no longer accept any SMS text messages.
ATTENTION: The system is NOT compatible with pure 3G SIM cards. Only 2G/GSM SIM cards and 3G SIM cards with 2G/GSM prole enabled
are supported. For more details, please contact your GSM operator.
ATTENTION: We also recommend you to disable call forwarding, voice mail/text message reports on missed/busy calls and similar services
that might cause incorrect system operation. Please contact your GSM operator for more details on these services and how to disable them.
9
ESIM4 Manual v1.5
9EN
NOTE: For maximum system reliability we recommend you do NOT use a Pay As You Go SIM card. Otherwise, in the event of insucient credit
balance on the SIM card, the system would fail to make a phone call or send SMS text messages.
NOTE: We advise you to choose the same GSM SIM provider for your system as for your mobile phone. This will ensure the fastest, most
reliable SMS text message delivery service and phone call connection.
NOTE: Even though the installation process of ESIM4 is not too complicated, we still recommend to perform it by a person with basic knowl-
edge in electrical engineering and electronics to avoid any system damage.
4. GENERAL OPERATIONAL DESCRIPTION
The battery powered GSM dialler ESIM4 uses the GSM network for event transmission by SMS text message and/or phone call to the listed user phone numbers. In addition to being informed about alarm and restore events of the inputs, the users can use the system to supply power to an auxiliary device and control one electrical appliance using an output or measure the temperature using up to 8 temperature sensors.
The system has two inputs (normally closed or normally open) for a detection device connection. By enabling the ATZ mode and connecting the resistors, 2 detection devices can be connected to each input. The system also supplies 12 volt power to an auxiliary device, such as, pressure sensor. In addition, the system comes equipped with a built-in shock sensor for any vibration detection where the system is placed.
ESIM4 can also be used as a mini alarm system supporting arming/disarming feature by iButton key.
ESIM4 can control 1 electrical appliance on receipt of the correct SMS text message or via ELDES Conguration Tool software. For example, users can turn on or o the heating, lighting, lift the gates, blinds etc.
By default, when an authorised number calls to the system, the device answers and the user can listen for 60 seconds to what is going on in the premises. This function works only when a microphone is connected. The system will ignore SMS requests and voice calls coming from unknown phone numbers.
Most of the time the system operates in Sleep mode allowing to save battery power for up to 2 years. However, when an event occurs, requiring the device to send SMS messages and/or dial one of the listed user phone numbers, the device will switch to Wake-Up mode.
5. CONFIGURATION METHODS
5.1. SMS Text Messages
!!! In this user manual the underscore character ”_” represents one space character. Every underscore character must be replaced by a single space character. There must be no spaces or other unnecessary characters at the beginning and at the end of the SMS text message.
In order to congure and control the system by SMS text message, send the text command to the ESIM4 system phone num­ber from one of the listed user phone numbers. The system supports multiple text commands arranged in a single SMS text
SMS
message. The structure of SMS text message consists of 4-digit SMS password (the default SMS password is 0000 – four zeros), the parameter and value. For some parameters the value does not apply e. g. STATUS. The variables are indicated in lower-case letters, while a valid parameter value range is indicated in brackets.
For more details on how to encrypt an SMS text message in a QR code, please refer to 5.3. QR Codes and ELDES Conguration Tool software’s HELP section.
5.2. ELDES Conguration Tool
Cong
10
10 EN
Software ELDES Conguration Tool is intended for ESIM4 battery powered GSM dialler conguration via USB port locally. This software simplies system conguration process by allowing to use a personal computer in the process. Before starting to use
Tool
ELDES Conguration Tool software, please read the user guide provided in the software’s HELP section.
ELDES Conguration Tool is freeware and can be downloaded at: www.eldes.lt/download
NOTE: Conguration by USB cable and ELDES Conguration Tool software does not require the batteries to be inserted in the device.
ESIM4 Manual v1.5
5.3. QR Codes
For user convenience, ELDES Conguration Tool software comes equipped with QR code generator allowing to arrange a single or multiple text commands in a single SMS text message and encrypt it in a QR code. Once the QR code is generated, the user using his mobile phone’s built-in camera can take a picture of the code right from his monitor’s screen, then decrypt it to the SMS text message using his mobile phone’s application and send the SMS text message to the system.
Cong
Generate QR code
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
6. SMS PASSWORD
For security reasons, the system uses the following type of password:
SMS password – 4-digit password used for system conguration and control from user phone number by SMS text message . By default, SMS password is 0000, which MUST be changed!
SMS text message content:
wwww_PSW:ssss
Set SMS password
SMS
Value: wwww – 4-digit default SMS password; ssss – 4-digit new SMS password; range –
[0001... 9999].
Example: 0000_PSW:1111
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
ESIM4 Manual v1.5
11
11EN
7. USER PHONE NUMBERS
The system supports up to 10 user phone numbers identied as User 1 through 10. When the phone number is set, the user will be able to congure the system by SMS text messages as well as to receive the alarm/restore phone calls and SMS text messages from the system (see 10.3. Alarm/Restore Notications).
By default, the system accepts incoming calls and SMS text messages from any phone number. Once a user phone number is listed, the system ignores any incoming calls and SMS text messages from a non-listed phone number as well as it rejects the SMS text messages containing wrong SMS password even from a listed user phone number.
To set User 1 phone number is mandatory, while the other 9 are optional. The supported phone number formats are the following:
• International (with plus) – The phone numbers must be entered starting with plus and an international country code in the following
format: +[international code][area code][local number], example for UK: +44170911XXXX1.
• International (with 00) – The phone numbers must be entered starting with 00 and an international country code in the following
format: 00[international code][area code][local number], example for UK: 0044170911XXXX1.
• Local – The phone numbers must be entered starting with an area code in the following format: [area code][local number], example
for UK: 0170911XXXX1.
SMS text message content:
Set user phone number
ssss_NRup:ttteeellnnuumm
SMS
Value: ssss – 4-digit SMS password; up – user phone number slot, range – [1... 10]; ttteeelln-
nuumm – up to 15 digits user phone number.
Example: 1111_NR1:+44170911XXXX1
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
View user phone numbers
Delete user phone number
ATTENTION: NEVER add a phone number of the device’s SIM card as a user phone number!
ATTENTION: Once User 1 phone number is set, it will be restricted to modify it only.
NOTE: Multiple user phone numbers can be set by a single SMS text message, e.g.: 1111_NR1:+4417091111111_ NR2:+4417091111112_
NR6:017091111113_NR10:+4417091111114
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
SMS text message content:
ssss_NRup:
SMS
Value: ssss – 4-digit SMS password; up – user phone number slot, range – [1... 10].
Example: 1111_NR4:
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
12
12 EN
ESIM4 Manual v1.5
8. DATE AND TIME
The system comes equipped with internal real-time clock (RTC) that keeps track of the current date and time. Once the system is up and running, the user must set the correct date and time, otherwise the system will not operate properly. After shutting down and starting up the system, the date and time must be set again.
SMS text message content:
ssss_CLK:yyyy.mm.dd_hr:mn
Set date and time
View date and time
For more details on how to view system’s information that may include date and time, please refer to 16. SYSTEM INFORMATION. STATUS SMS.
8.1. Automatic Date and Time Synchronization
This feature enables the system to set the date and time automatically without the user being involved in this process. The system supports the following method of automatic date and time synchronization that is used whenever the system switches to Wake-Up mode:
• Via GSM network – Once enabled, the system automatically sends a date/time request to the GSM operator. This method is the most accurate synchronization method. Some GSM operators might not support it.
By default, synchronization via GSM network is disabled. To enable/disable automatic date and time synchronization via GSM network, please refer to the following conguration methods.
Enable automatic date and time synchronization
SMS
Value: ssss – 4-digit SMS password; yyyy – year; mm – month, range – [01... 12]; dd – day,
range – [01... 31]; hr – hours, range – [00... 23]; mn – minutes, range – [00... 59].
Example: 1111_CLK:2013.03.16_14:33
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
SMS text message content:
ssss_STATUS
SMS
Value: ssss – 4-digit SMS password.
Example: 1111_STATUS
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
SMS text message content:
ssss_MTIME:ON
SMS
Value: ssss – 4-digit SMS password;
Example: 1111_MTIME:ON
Disable automatic date and time synchronization
ESIM4 Manual v1.5
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
SMS text message content:
ssss_MTIME:OFF
SMS
Value: ssss – 4-digit SMS password;
Example: 1111_MTIME:OFF
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
13
13EN
9. SLEEP AND WAKE-UP MODES
The system can operate in one of the following modes at a time:
• Wake-Up – The micro-controller and the GSM modem are active and the system is ready to send and accept the SMS text messages and
phone calls to/from the listed user phone number.
• Sleep – The micro-controller and the GSM modem are disabled and the system will not be able to accept the SMS text messages or
phone calls from the listed user phone number. Normally, this mode is used most of the system’s uptime to signicantly extend battery life.
The system starts up in Wake-Up mode and operates in this mode for 3 minutes. When the 3-minute period expires, the system will switch to Sleep mode and operate in this mode until an event occurs or Wake-Up scheduler comes into eect (see 9.1. Wake-Up Scheduler).
When an event occurs, the system will follow this pattern:
1) Switches to Wake-Up mode.
2) Noties the user by SMS text message and/or phone call.
3) Stays in Wake-Up mode for 10 seconds.
4) Returns to Sleep mode.
By default, after notifying the user on a certain event, the system will stay in Wake-Up mode for 10 second time period. To set a dierent time period, please refer to the following conguration methods.
Set time period to stay in Wake-Up mode after notifying the user
View Wake-Up mode parameters
ATTENTION: All 4 batteries must be inserted in the device for the system to run in Wake-Up mode. If the system is connect to the PC only via
USB cable, it will NEVER switch to Wake-Up mode.
NOTE: 0 value makes the system to instantly return to Sleep mode after notifying the user.
For more details on the system events and the algorithm of how the system sends the notications, please refer to 17. SYSTEM NOTIFICATIONS.
SMS text message content:
SMS
ssss_MONT:se
Value: ssss – 4-digit SMS password; se – seconds, range – [0... 65535].
Example: 1111_MONT:25
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
Cong
This operation may be carried out from the PC using the ELDES Conguration Tool software.
Tool
14
14 EN
ESIM4 Manual v1.5
Loading...