SAFETY INSTRUCTIONS
Please read and follow these safety guidelines to safeguard yourself and others:
DO NOT use the device in hazardous environment.
DO NOT expose the device to high humidity, chemical environment or mechanical impact.
DO NOT attempt to repair the device yourself – any repairs must be carried out by fully qualied personnel only.
Please, use the 10-24V 50Hz ~ 210mA AC or 10-24V 210mA DC power supply unit that meets the EN 60950-1 standard. Any additional device you connect to the device, such as a computer, must also be powered by an EN 60950-1 approved supply. When connecting the power supply to the device, switching the polarity terminal places does not have any aect.
External power supply can be connected to AC mains only inside installation room with automatic 2-pole circuit breaker capable of disconnecting circuit in the event of short circuit or over-current condition. Open circuit breaker must have a gap between connections of more than 3mm and the disconnection current 5A.
AC/DC
ELAN3
USB cable
Disconnect the mains power before installing. Never install or carry out maintenance during stormy weather. The electric socket that powers the device must be easily accessible.
To switch the device o, unplug the external electric power supply or any other linked device that the device is powered from. A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (Fuse F1 model – miniSMDC 0,5A).
The WEEE (Waste Electrical and Electronic Equipment) symbol on this product (see left) means it must not be disposed of in household waste. To prevent possible harm to human health and/or the environment, you must dispose of this product in an approved and environmentally safe recycling facility. For further information contact your system supplier, or your local waste authority.
AC 230V 50 Hz/DC 24V
Phase
Null
PE
Copyright © “ELDES UAB”, 2014. All rights reserved
It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, “ELDES UAB” declares that the SNMP Ethernet Controller ELAN3-SNMP is in compli­ance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt.
2
2 EN
ELAN3 SNMP Ethernet Controller
CONTENTS
1. GENERAL INFORMATION ...........................................................................................................................................................5
2. TECHNICAL SPECIFICATIONS ....................................................................................................................................................5
2.1. Electrical & Mechanical Characteristics .........................................................................................................................................................5
2.2. Main Unit, LED Indicator & Connector Functionality ...................................................................................................................................6
2.3. Wiring Diagrams ................................................................................................................................................................................................7
3. INSTALLATION ...........................................................................................................................................................................8
4. GENERAL OPERATIONAL DESCRIPTION....................................................................................................................................9
5. CONFIGURATION, CONTROL AND MONITORING METHODS .....................................................................................................9
5.1. Web Browser ......................................................................................................................................................................................................9
The following section is intended for input conguration. .................................................................................................................................11
5.2. SNMP Manager.................................................................................................................................................................................................14
6. TECHNICAL SUPPORT ............................................................................................................................................................. 17
6.1. Troubleshooting .............................................................................................................................................................................................17
6.2. Restoring Default Parameters ......................................................................................................................................................................17
6.3. Updating the Firmware via USB Cable ........................................................................................................................................................17
ELAN3 SNMP Ethernet Controller
3
3EN
Limited Liability
The buyer agrees that the device will reduce the risk of re, theft, burglary or other danger but that it does not guarantee against the occurrence of such events.
“ELDES UAB” will not take any responsibility for the loss of personal eects, property or revenue whilst using the device. The liability of “ELDES UAB” is limited to the value of the device purchased.
“ELDES UAB” is not aliated with any mobile/wireless/cellular provider and is therefore not responsible for the quality of such services.
Manufacturer Warranty
The device carries a 24-month manufacturer warranty from “ELDES UAB”.
The warranty begins the day the device is purchased by the user and the receipt must be retained as proof of purchase date. The warran­ty remains valid only if the device is used as intended, following all guidelines outlined in this manual and in accordance with the operat­ing conditions specied.
The warranty is void if the device has been exposed to mechanical impact, chemicals, high humidity, uids, corrosive and hazardous environments or force majeure factors.
Dear Customer,
Thank you for choosing to purchase the SNMP Ethernet Controller ELAN3-SNMP. Your thoughtful decision will ensure reliable solution for many years as all ELDES products are manufactured to meet the highest standards.
We are condent that you will be completely satised with your product. However, in the unlikely event that you do experience a prob­lem, please contact the dealer from whom you made your purchase.
UAB ELDES
CONTENTS OF PACK
Item ................................................... Quantity
1. ELAN3-SNMP......................................................1
2. User manual........................................... 1
Not included:
Power supply unit - can be obtained from your local distributor.
Ethernet cable - can be obtained from your local distributor.
Temperature sensor - can be obtained from your local distributor.
miniUSB cable - can be obtained from your local distributor.
4
4 EN
ELAN3 SNMP Ethernet Controller
1. GENERAL INFORMATION
ELAN3-SNMP is a micro-controller based device used to inform users about the state changes on digital or analog inputs and control up to 2 electrical appliances connected to the open-collector outputs. These functions can be congured via web-browser or SNMP Manager software compatible with SNMP (Simple Network Management Protocol) v1.0.
Examples of using the device:
Any electrical appliance control: lighting, watering, heating etc.
Remote reboot of the “frozen” devices, such as computer network or a server.
Main features:
Supported Ethernet connectivity: 10/100 Mbit.
Supported SNMP protocol: v1.0
User name/password-protected web-based remote conguration, monitoring and control.
4 inputs and 1 open-collector output or 3 inputs and 2 open-collector outputs.
Inputs customizable as NC or NO.
Supported input modes: digital or analog.
1-Wire interface for up to 8 temperature sensor connection intended for temperature monitoring in dierent areas.
Up to 3 destination IP addresses for trap message delivery.
2. TECHNICAL SPECIFICATIONS
2.1. Electrical & Mechanical Characteristics
Power supply ..................................................................................10-24V 50Hz ~ 210mA max. / 10-24V 210mA max.
Number of inputs/outputs............................................................4 inputs & 1 output or 3 inputs & 2 outputs (congurable)
Input value range ......................................................................... .0... 10V; 30V max.
Input internal resistance..............................................................40 kΩ
Output circuit ................................................................................. Open collector output. Output
is pulled to COM when turned ON.
Maximum commuted output values............................................30V 50Hz ~ 200mA /
30 V 200 mA
Maximum supported number of temperature sensors............8
Supported temperature sensor model ......................................Maxim®/Dallas® DS18S20, DS18B20
Enclosure dimensions...................................................................87x107x29 mm
PCB dimensions..............................................................................63x82x17 mm
Operating temperature range......................................................-20…+55 °C
Humidity...........................................................................................0-90% RH @ 0... +40 °C (non-condensing)
ELAN3 SNMP Ethernet Controller
5
5EN
2.2. Main Unit, LED Indicator & Connector Functionality
FRONT SIDE SIDE VIEW
1
RJ45
F1
AC/DC C1 COM Z2 Z1 +5V DATAZ3C2/
USB
USB
STATUS
DEF
Z4
LAN
(green)
RJ45
RJ45 10/100Base-T Ethernet port
USB Mini USB port for rmware update
DEF Pins for rmware update and restoring default parameters
STATUS Red light-emitting diode indicating micro-controller status
F1 miniSMDC 0,5A fuse
AC/DC Power supply terminals
C1 Open-collector output terminal
COM Common terminal
C2/Z4 Open-collector output | digital/analog input terminal
Z3, Z2, Z1 Digital/analog input terminal
+5V Temperature sensor power supply terminal
DATA Temperature sensor data terminal
LAN (green) Green light-emitting diode indicating Ethernet activity
LAN (yellow) Yellow light-emitting diode indicating Ethernet status
LAN (yellow)
6
6 EN
ELAN3 SNMP Ethernet Controller
Loading...