Please read and follow these safety guidelines to safeguard yourself and others:
• DO NOT use the device where it can cause potential danger and interfere with other devices – such as medical devices.
• DO NOT use the device in hazardous environment.
• DO NOT expose the device to high humidity, chemical environment or mechanical impact.
• DO NOT attempt to repair the device yourself – any repairs must be carried out by fully qualied personnel only.
Please, use the 10-24V 50Hz ~ 210mA AC or 10-24V 210mA DC power supply unit that meets the EN 60950-1 standard.
Any additional device you connect to the device, such as a computer, must also be powered by an EN 60950-1 approved
supply. When connecting the power supply to the device, switching the polarity terminal places does not have any aect.
External power supply can be connected to AC mains only inside installation room
with automatic 2-pole circuit breaker capable of disconnecting circuit in the event
of short circuit or over-current condition. Open circuit breaker must have a gap
between connections of more than 3mm and the disconnection current 5A.
AC/DC
ELAN3
USB cable
Disconnect the mains power before installing. Never install or carry out maintenance during stormy weather. The electric
socket that powers the device must be easily accessible.
To switch the device o, unplug the external electric power supply or any other linked device that the device is powered from.
A blown fuse cannot be replaced by the user. The replacement fuse has to be of the kind indicated by the manufacturer (Fuse
F1 model – miniSMDC 0,5A).
The WEEE (Waste Electrical and Electronic Equipment) symbol on this product (see left) means it must not be disposed of in
household waste. To prevent possible harm to human health and/or the environment, you must dispose of this product in an
approved and environmentally safe recycling facility. For further information contact your system supplier, or your local waste
authority.
It is strictly forbidden to copy and distribute information in this document or pass to a third party without an advanced
written authorization from “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related
products without a warning. Hereby, “ELDES UAB” declares that the SNMP Ethernet Controller ELAN3-SNMP is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity
may be consulted at www.eldes.lt.
2
2EN
ELAN3 SNMP Ethernet Controller
CONTENTS
1. GENERAL INFORMATION ...........................................................................................................................................................5
2.2. Main Unit, LED Indicator & Connector Functionality ...................................................................................................................................6
4. GENERAL OPERATIONAL DESCRIPTION....................................................................................................................................9
5. CONFIGURATION, CONTROL AND MONITORING METHODS .....................................................................................................9
5.1. Web Browser ......................................................................................................................................................................................................9
The following section is intended for input conguration. .................................................................................................................................11
6. TECHNICAL SUPPORT ............................................................................................................................................................. 17
6.3. Updating the Firmware via USB Cable ........................................................................................................................................................17
ELAN3 SNMP Ethernet Controller
3
3EN
Limited Liability
The buyer agrees that the device will reduce the risk of re, theft, burglary or other danger but that it does not guarantee against the
occurrence of such events.
“ELDES UAB” will not take any responsibility for the loss of personal eects, property or revenue whilst using the device. The liability of
“ELDES UAB” is limited to the value of the device purchased.
“ELDES UAB” is not aliated with any mobile/wireless/cellular provider and is therefore not responsible for the quality of such services.
Manufacturer Warranty
The device carries a 24-month manufacturer warranty from “ELDES UAB”.
The warranty begins the day the device is purchased by the user and the receipt must be retained as proof of purchase date. The warranty remains valid only if the device is used as intended, following all guidelines outlined in this manual and in accordance with the operating conditions specied.
The warranty is void if the device has been exposed to mechanical impact, chemicals, high humidity, uids, corrosive and hazardous
environments or force majeure factors.
Dear Customer,
Thank you for choosing to purchase the SNMP Ethernet Controller ELAN3-SNMP. Your thoughtful decision will ensure reliable solution
for many years as all ELDES products are manufactured to meet the highest standards.
We are condent that you will be completely satised with your product. However, in the unlikely event that you do experience a problem, please contact the dealer from whom you made your purchase.
2. User manual........................................... 1
Not included:
• Power supply unit - can be obtained from your local distributor.
• Ethernet cable - can be obtained from your local distributor.
• Temperature sensor - can be obtained from your local distributor.
• miniUSB cable - can be obtained from your local distributor.
4
4EN
ELAN3 SNMP Ethernet Controller
1. GENERAL INFORMATION
ELAN3-SNMP is a micro-controller based device used to inform users about the state changes on digital or analog inputs and control up to
2 electrical appliances connected to the open-collector outputs. These functions can be congured via web-browser or SNMP Manager
software compatible with SNMP (Simple Network Management Protocol) v1.0.
Examples of using the device:
• Any electrical appliance control: lighting, watering, heating etc.
• Remote reboot of the “frozen” devices, such as computer network or a server.
Main features:
• Supported Ethernet connectivity: 10/100 Mbit.
• Supported SNMP protocol: v1.0
• User name/password-protected web-based remote conguration, monitoring and control.
• 4 inputs and 1 open-collector output or 3 inputs and 2 open-collector outputs.
• Inputs customizable as NC or NO.
• Supported input modes: digital or analog.
• 1-Wire interface for up to 8 temperature sensor connection intended for temperature monitoring in dierent areas.
• Up to 3 destination IP addresses for trap message delivery.