User manual v1.5
Compatible with:
• ESIM364 all versions.
• EPIR v05.06.02 and up + EWT2 v16.17 and up.
• EPIR2 all versions.
• EPIR3 all versions
Main features:
• Alarm system arming and disarming.
• Arming and disarming in Stay mode.
• System parameter conguration.
• PGM output control.
• Visual indication by LED indicators.
• Audio indication by built-in buzzer.
• Keypad partition switch.
EKB3W is a wireless LED keypad intended to use with ELDES alarm systems. The system conguration by EKB3W keypad is performed by
activating the Conguration Mode and entering the required parameters and values. It is possible to connect up to 4 EKB3W devices to ELDES
alarm system at a time. The maximum wireless connection range is 150m (492.13ft) (in open areas).
NOTE: For complete information on device operation with ELDES alarm system, please refer to ELDES alarm system installation manual
located at www.eldes.lt/download
1. CONTENT OF PACK
Item Quantity
1. EKB3W .......................................................... 1
2. User manual.................................................. 1
3. 5,6kΩ resistor ...............................................1
4. Screws .......................................................... 4
5. 1,5V Alkaline AAA type batteries ............ 3
2. TECHNICAL SPECIFICATIONS
2.1 Electrical and Mechanical Characteristics
Battery type ................................................................... 1,5V Alkaline AAA type LR03 (IEC) / 24A (ANSI/NEDA)
Number of batteries .....................................................3
Battery operation time.................................................~12 months*
Wireless band ................................................................. ISM868/ISM915
Range of operating temperatures .............................-30...+55 °C (-22... +131°F)
Humidity ......................................................................... 0-90% RH @ 0... +40°C (0-90% RH @ +32... +104°F) (non-condensing)
Dimensions ..................................................................... 140x100x18mm (5.51x3.94x0.71in)
Wireless communication range ..................................Up to 30m (98.43ft) in premises; up to 150m (492.13ft) in open areas
Compatible with alarm systems .................................ELDES Wireless
* This operating time may vary in dierence conditions.
2.2 LED Functionality
ARMED Steady ON - alarm system is armed / exit delay in progres; ashing - Conguration mode activated
READY Steady ON - system is ready – no violated zones and tampers
SYSTEM Steady ON - system faults; ashing - violated high-numbered zones
BYPS Steady ON - zone bypass mode
1-12 Steady ON - violated zone / ashing - violated tamper (only for EPIR/EPIR2/EPIR3)
2
2 EN
USER MANUAL EKB3W V1.5
2.3 Keys Functionality
[BYPS] Zone bypass mode
[CODE] System fault list / violated high-numbered zone indication / violated tamper indication (only for ESIM364) / violated high-
[*] 1st character for Conguration mode activation/deactivation command (for ESIM364 up to v02.06.20; EPIR all versions; EPIR2
numbered tamper indication (only for EPIR/EPIR2/EPIR3)
up to v1.01.08) / clear typed in characters / keypad partition switch (if enabled; only for ESIM364 up to v02.06.20)
[#] Conrm (enter) command
[0] ... [9] Command typing
[1]... [2] Keypad partition switch (for ESIM364 v02.07.00 and up)
[STAY] Manual system arming in Stay mode
[INST] 1st character for Conguration mode activation/deactivation command (for EPIR2 v1.01.11 and up; EPIR3 all versions;
ESIM364 v02.07.00 and up)
2.4 Main Unit & Connector Functionality
1
ARMED
READY
SYSTEM BYPS
1
2
3
4
5
6
A B
FRONT SIDE
7
8
9
10
11
12
1 2 3
4 5 6
8 9
7
0 #
*
STAY
BYPS
INST
CODE
2
+ -
+ -
BATTERY
BATTERY
BATTERY
BACK SIDE
+-
TAMPER
5,6 kOhm
Z1COM
TAMPER Tamper switch
+ / - Battery slots
USER MANUAL EKB3W V1.5
COM Common terminal
Z1 Security zone terminal
3
3EN