User Manual v1.4
Compatible with:
• ESIM264 v07.14.02 and up.
• ESIM364 v02.06.01 and up.
Main features:
• Alarm system arming & disarming;
• Stay mode activation & deactivation;
• System parameter conguration;
• PGM output control;
• Visual indication by LED indicators;
• Audio indication by built-in buzzer;
• Keypad partition switch.
EKB3 is a LED keypad intended to use with ELDES alarm systems. The system conguration by EKB3 keypad is performed by activating the Conguration Mode and entering the required parameters & values. ELDES alarm systems allow to connect up to 4
EKB3 keypads.
NOTE: For complete system conguration & control using EKB3 keypad, please refer to ELDES alarm system installation manual
located at: www.eldes.lt/en/download
1. Package content
1. EKB3 ............................................ qty. 1
2. User manual ............................ qty. 1
3. 5,6kΩ resistor .......................... qty. 1
2
2. Technical specications
2.1 Electrical and mechanical characteristics
Power supply 12-14V 150mA max
Maximum keypad connection cable length 100 m.
Dimensions 140x100x18mm
Range of Operating Temperatures -30...+55ºC
2.2 LED Functionality
ARMED Steady ON - alarm system is armed / exit delay in progress; ashing - Conguration mode activated
READY Steady ON - system is ready – no violated zones and tampers
SYSTEM Steady ON - system faults; ashing - violated high-numbered zones
BYPS Steady ON - zone bypass mode
1-12 Steady ON - violated zone
2.3 Keys Functionality
[BYPS] Zone bypass mode
[CODE] System fault list / violated high-numbered zone indication / violated tamper indication
[*] 1st character for Conguration mode activation/deactivation command (for ESIM364 up to v02.06.20 and ESIM264 all
[#] Conrm (enter) command
[0] ... [9] Command typing
[1] ... [4] Keypad partition switch (only for ESIM364) / steady ON - armed partition indication (only for ESIM364) / ashing - vio-
[0] Simultaneous 4-partition arming (only for ESIM364)
[STAY]
[INST] 1st character for Conguration mode activation/deactivation command (only for ESIM364 v02.07.00 and up)
versions) / clear typed in characters / keypad partition switch (if enabled; only for ESIM264)
lated partition indication (only for ESIM364)
Manual system arming in Stay mode
2.4 Connector functionality
AUX+ Positive 12-14V power supply terminal
AUX- Negative 12-14V
G RS485 interface for communication (green wire)
Y RS485 interface for communication (yellow wire)
COM Common terminal for Z1
Z1 Security zone terminal
Z2 N/A
A B
ARMED
READY
SYSTEM BYPS
7
1
8
2
9
3
10
4
11
5
12
6
USER MANUAL EKB3 V1.4 3
power supply terminal
FRONT SIDE
1 2 3
4 5 6
7
8 9
0 #
*
Fig. No. 1
STAY
BYPS
INST
CODE
BACK SIDE
3 2
DIP SWITCH
Fig. No. 2
TAMPER
COM Y
Z2 Z1
AUX-
G
AUX+