Eldes EBU1 User Manual

BACKUP POWER SUPPLY
EBU1
Manual v1.1
Please read and follow these safety guidelines in order to maintain safety of operators and people around:
• Don’t use the system where it can be interfere with other devices and cause any potential danger.
• Don’t use the system with medical devices.
• Don’t use the system in hazardous environment.
• Don’t expose the system to high humidity, chemical environment or mechanical impacts.
• Don’t attempt to personally repair the system.
• System label is on the bottom side of the device.
System EBU1 is a device mounted in limited access areas. Any system repairs must be done only by qualied, safety aware personnel.
EBU1 must be powered by 12-30V 50mA power supply without additional load. All system must be powered by power supply which must meet power requirements by connected electronic appliance plus EBU1, must be approved by LST EN 60950-1 standard and be easily accessible
Any additional devices linked to the system EBU1 (computer, sensors, relays etc.) must be approved by LST EN 60950-1 standard.
Mains power must be disconnected before any installation or tuning work starts. The system installation or maintenance must not be done during stormy conditions.
The device is switched o by 2-pole circuit breaker and back-up battery removal from EBU1 device.
Fuse F1 type – miniSMDC 500mA. Replacement fuses have to be exactly the same as indicated by the manufacturer.
The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see right) or its documentation indicates that the pro­duct must not be disposed of together with household waste. To prevent possible harm to human health and/or the environment, the product must be disposed on in an approved and environmentally safe recycling process. For further information on how to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in your area.
Copyright © “ELDES UAB”, 2011. All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authorization by “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, ELDES UAB declares that this backup unit EBU1 is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. The declaration of conformity may be consulted at www.eldes.lt
Limited Liability
The buyer must agree that the system will re­duce the risk of re, theft, burglary or other dan­gers but does not guarantee against such events.
“ELDES UAB” will not take any responsibility re­garding personal or property or revenue loss while using the system.
“ELDES UAB” liability according to local laws
does not exceed value of the purchased system.
“ELDES UAB” is not aliated with any of the cellular providers therefore is not responsible for the quali­ty of cellular service.
CONTENT
1. General Information ......................................................... 4
1.1 Function ..................................................................................................................4
1.2 Operation Description .......................................................................................4
1.3 Connector Functionality ...................................................................................4
1.4 Technical Specications ....................................................................................5
1.5 Connection Circuit ..............................................................................................5
1.6 System Installation ..............................................................................................5
2. Battery replacement ......................................................... 5
3. Technical Support ............................................................. 5
Manufacturer Warranty
The system carries a 24-month warranty by the manufacturer “ELDES UAB”. Warranty period starts from the day the system has been purchased by the end user. The warranty is valid only if the system has been used as intended, following all guidelines listed in the manual and within specied operating conditions. Receipt must be kept as a proof of purchase date.
The warranty is voided if the system has been exposed to mechanical impact, chemicals, high humidity, uids, corrosive and
hazardous environment or other force majeure factors.
Package content:
1. EBU1 ......... ..............................................................qty. 1
2. EBU1 User Manual. ..............................................qty.1
About User Manual
This document describes a backup system EBU1, it’s installation and operation. It is very important to read User Manual before
start using the system.
1. General Information
1.1 Function
EBU1 is a power supply backup device used to connect various electronic appliances, such as sensors, adapters, dialers, automation systems and other electronic devices.
1.2 Operation Description
ELDES EBU1 power supply backup unit has an internal 9V battery which is used to power up a connected device in case of power supply failure. The DC output voltage is the same as DC input voltage. In case of main power is lost or cut, the system automatically activates PF (Power Failure) output connector and begins powering up the connected electronic device by internal EBU1 battery. After the main power source restores, the system charges the internal battery with built-in battery charger. EBU1 system comes with wires of 15cm length . This device can be used with any electronic device, which is powered by 9V. EBU1 can be used with the following ELDES devices: ESIM021, ESIM251, EW1, ELAN1 etc.
1.3 Connector Functionality
Fig. No. 1
Connector functionality
Wire color Labeling Explanation
Red DC in Main power supply positive connector Black COM Common contact Yellow DC out Power supply positive connector Blue PF Power failure output (open collector)
4
1.4 Technical Specications
Electrical and mechanical specications
DC in Main power supply positive connector Voltage - 12-30V 500 mA max. DC out Power supply positive connector DC in 500 mA max. PF
1 R
OUT
Open collector output. Output is pulled to COM when power failure detected (when voltage drops below 11,5V)
Battery voltage; capacity 9V 250mAh NiMH Max. battery charge current 250mAh (0...+50ºC) Operating temperature range -20...+55ºC Dimensions 80x36x21mm
Voltage - 30V; current - 20 mA
1.5 Connection Circuit
System EBU1 and electronic appliance unit COM must be connected. Output signal PF wire should be connected to electronic appliance input zone.
1.6 System installation
1. Fix the system box with two screws to the wall.
2. Connect the circuit as shown in Fig. No.2. Power supply cables are connected last. Electronic appliance power supply must be disconnected before connecting EBU1.
Even though backup system EBU1 installation is not complicated, it is recommended to be performed by a person with basic knowledge in electrical engineering and electronics to avoid any system damage.
Connection diagram
+12...+30V +12...+30V
Fig. No. 2 Fig. No. 3
During power failure (equivalent diagram)
+6,5...+10,5V
USER MANUAL EBU1 V1.1 5