Elation Professional DJ Equipment User Manual

ELAR EX TRIPAR
ELAR EX TRIPAR Introduction
Unpacking: Thank you for purchasing the ELAR EX TRIPAR by Ela-
tion Architectural®. Every ELAR EX TRIPAR has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the shipping carton for damage that may have occurred during ship­ping. If the carton appears to be damaged, carefully inspect your x­ture for any damage and be sure all accessories necessary to operate the unit has arrived intact. In the case damage has been found or parts are missing, please contact our customer support number for further instructions. Do not return this unit to your dealer without rst contact­ing customer support.
Introduction: The ELAR EX TRIPAR is part of Elation Architectural®
continuing pursuit for creating high quality affordable intelligent fix­tures. The ELAR EX TRIPAR is a powerful DMX intelligent RGB LED wash. This wash is light weight and compact which makes it a great piece for mobile DJ’s and clubs. The unit has 4 operating modes; Auto Run mode, Program mode, RGB mode, and DMX Controlled. This unit can be used as a stand alone unit or in a master-slave conguration.
Customer Support: ©Elation® provides a customer support line, to
provide set up help and to answer any question should you encounter problems during your set up or initial operation. You may also visit us on the web at www.elationlighting.com for any comments or sugges­tions. Service Hours are Monday through Friday 9:00 a.m. to 5:00 p.m. Pacic Standard Time. Voice: (323) 582-3322 Fax: (323) 832-9142 E-mail: support@elationlighting.com
5/10
User Instructions
©Elation Architectural®
Los Angeles CA. 90040
www.elationlighting.com
Warning! To prevent or reduce the risk of electrical shock or re, do
not expose this unit to rain or moisture.
Caution! There are no user serviceable parts inside this unit. Do not
attempt any repairs yourself, doing so will void your manufactures war­ranty. In the unlikely event your unit may require service please contact
©Elation customer support.
PLEASE recycle the shipping carton when ever possible.
6122 S. Eastern Ave.
Elation Architectural - www.elationlighting.com - ELAR EX TRIPAR Instruction Manual Page 2
ELAR EX TRIPAR General Instructions
ELAR EX TRIPAR Safety Precautions
To optimize the performance of this product, please read these operat­ing instructions carefully to familiarize yourself with the basic operations of this unit. These instructions contain important safety information regarding the use and maintenance of this unit. Please keep this manual with the unit, for future reference.
ELAR EX TRIPAR Features
• Multi-Colors
• Tri LEDs - 3 LEDs Per Lens
• Built in Microphone
• 4 Operating Modes
• DMX-512 protocol
• 4 DMX Modes: 3 Channel Mode, 4 Channel Mode, 5 Channel & 6 Channel Mode
• Dimming 0-100% in 4 Channel Mode, 5 Channel Mode, & 6 Channel Mode.
• Daisy Chain Units Together in DMX Mode
ELAR EX TRIPAR Warranty Registration
The ELAR EX TRIPAR carries a two year limited warranty. Please fill out the enclosed warranty card to validate your purchase. All returned service items whether under warranty or not, must be freight pre-paid and accompany a return authorization (R.A.) number. The R.A. number must be clearly written on the outside of the return package. A brief description of the problem as well as the R.A. number must also be written down on a piece of paper included in the shipping carton. If the unit is under warranty, you must provide a copy of your proof of purchase invoice. You may obtain a R.A. number by contacting our customer support team on our customer support number. All pack­ages returned to the service department not displaying a R.A. number on the outside of the package will be returned to the shipper.
• Be sure that the local power outlet match that of the required volt­ age for your unit.
• Do not attempt to operate this unit if the power cord has been frayed or broken. Do not attempt to remove or break off the ground prong from the electrical cord. This prong is used to reduce the risk of electrical shock and re in case of an internal short.
• Disconnect from main power before making any type of connection.
• Do not remove the cover under any conditions. There are no user serviceable parts inside.
• Never open this unit, it is factory sealed for a reason.
• Never plug this unit in to a dimmer pack
• Always be sure to mount this unit in an area that will allow proper ventilation. Allow about 6” (15cm) between this device and a wall.
• Do not attempt to operate this unit, if it becomes damaged.
• During long periods of non-use, disconnect the unit’s main power.
• Always mount this unit in safe and stable matter.
• Power-supply cords should be routed so that they are not likely to be walked on or pinched by items placed upon or against them, paying particular attention to the point they exit from the unit.
• Cleaning -The fixture should be cleaned only as recommended by t he manufacturer. See page 13 for cleaning details.
• Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (inclu­ d ing amplifiers) that produce heat.
• The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilled into the appliance. C. The appliance does not appear to operate normally or exhibits a marked change in performance.
Elation Architectural - www.elationlighting.com - ELAR EX TRIPAR Instruction Manual Page 4Elation Architectural - www.elationlighting.com - ELAR EX TRIPAR Instruction Manual Page 3
ELAR EX TRIPAR Set Up
POWER
SOUND
REMOTE
CONTROL
INPUT
POWER
INPUT OUTPUT
1
2
3
Termination reduces signal errors and avoids signal transmission problems and interference. It is always advisable to connect a DMX terminal, (Resistance 120 Ohm 1/4 W) between PIN 2 (DMX-) and PIN 3 (DMX +) of the last fixture.
ELAR EX TRIPAR Set Up
Power Supply: The Elation ELAR EX TRIPAR contains an electronic ballast, which will auto sense the voltage when it is plugged into the power source. With the electronic power supply unit you do not need to worry about wall voltage, this unit can be plugged in anywhere.
DMX-512: DMX is short for Digital Multiplex. This is a universal pro-
tocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions from the controller to the fixture. DMX data is sent as serial data that trav­els from fixture to fixture via the DATA “IN” and DATA “OUT” XLR ter­minals located on all DMX fixtures (most controllers only have a DATA “OUT” terminal).
DMX Linking: DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller, as long as all xtures and the controller are DMX compli­ant. To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
Data Cable (DMX Cable) Requirements (For DMX Operation):
The ELAR EX TRIPAR can be controlled via DMX-512 protocol. The ELAR EX TRIPAR has 4 DMX Modes. The DMX address is set using the ELAR WR controller. Your unit and your DMX controller require a approved DMX-512 110 Ohm Data cable for data input and data output. We highly recommend the ELAR 3C-1M or ELAR 3C-5M DMX Cables. These cables can be used in dry, damp, or wet areas in indoor or out­door enviroments. The rubber neoprene outer jacket is weather and ozone resistant making the cables suitable for outdoor use. This cable may be purchased at almost all professional sound and lighting stores. Remember that DMX cable must be daisy chained and cannot be split.
Special Note: Line Termination.
When longer runs of cable are
5-Pin XLR DMX Connectors.
Some manufactures use 5-pin DMX-
512 data cables for DATA transmission in place of 3-pin. 5-pin DMX xtures may be implemented in a 3-pin DMX line. When inserting standard 5-pin data cables in to a 3-pin line a cable adaptor must be used, these adaptors are readily available at most electric stores. The chart below details a proper cable conversion.
3-Pin XLR to 5-Pin XLR Conversion
Conductor 5-Pin XLR Male (In)3-Pin XLR Female (Out)
Ground/Shield
Data Compliment (- signal)
Data True (+ signal)
Not Used
Not Used
Pin 1
Pin 2
Pin 3
Pin 1
Pin 2
Pin 3
Do Not Use
Do Not Use
Elation Architectural - www.elationlighting.com - ELAR EX TRIPAR Instruction Manual Page 5
Elation Architectural - www.elationlighting.com - ELAR EX TRIPAR Instruction Manual Page 6
Loading...
+ 5 hidden pages