Eizo ECLIENT SC1 User Manual

- For Administrator -
For Microsoft Windows CE.NET
Version A
Please confirm the version of the software built in eClient, and refer to the suited User's Manual (Refer to the User's Manual Version List on next page).
This is the manual for the following software version.
*
Microsoft Windows CE:
*
Microsoft Terminal Server Client: Ver. 8.0.1 or later
* Ctrix
ICA Client Software:
Ver. 7.23 or later

User’s Manual Version List

A handling description changes with versions of the software built in eClient. Please refer to below.
NOTE
The version of software built in eClient can be checked with a [System]-[ICA] tab of [Terminal Properties].
OS: Microsoft Windows CE .NET
Software
Manual
A
(This manual)
Microsoft Windows CE
4.20 Rev.3.0.2 or later Version 8.0.1 or later Version 7.23 or later
Microsoft Windows
Terminal Server
ICA Client
Software

SAFETY SYMBOLS

This manual uses the safety symbols below. They denote critical information. Please read them carefully.
WARNING
Failure to abide by the information in a WARNING may result in serious injury and can be life threatening.
CAUTION
Failure to abide by the information in a CAUTION may result in moderate injury and/or property or product damage.
Indicates a prohibited action.
Indicates to ground for safety.
Copyright© 2004 EIZO NANAO CORPORATION. All rights reserved. No part of this manual may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, or otherwise, without the prior written permission of EIZO NANAO CORPORATION. EIZO NANAO CORPORATION is under no obligation to hold any submitted material or information confidential unless prior arrangements are made pursuant to EIZO NANAO CORPORATION's receipt of said information. Although every effort has been made to ensure that this manual provides up-to-date information, please note that EIZO monitor specifications are subject to change without notice.
ENERGY STAR is a U.S. registered mark. Apple and Macintosh are registered trademarks of Apple Computer, Inc. DPMS is a trademark and VESA is a registered trademark of Video Electronics Standards Association. VGA is a registered trademark of International Business Machines Corporation. Windows is a registered trademark of Microsoft Corporation. ScreenManager and PowerManager are trademarks of EIZO NANAO CORPORATION. FlexScan and EIZO are registered trademarks of EIZO NANAO CORPORATION.
As an ENERGY STAR that this product meets the ENERGY STAR guidelines for energy efficiency.
®
Partner, EIZO NANAO CORPORATION has determined
3

TABLE OF CONTENTS

1. INTRODUCTION ..................................................................................... 5
1-1. General Description ......................................................................................5
1-2. Features ........................................................................................................5
1-3. Package Contents..........................................................................................6
1-4. Controllers & Connectors ............................................................................7
2. CONNECTING the eClient SC1............................................................. 9
2-1. Setting up the eClient SC1 ............................................................................9
3. SETTING UP the eClient SC1.............................................................. 15
4. ADDING & CHANGING A CONNETION NAME................................... 25
4-1. Adding a Connection Name........................................................................25
4-2. Setting an Autostart Connection.................................................................28
4-3. Modifying a Connection Name...................................................................28
5. How to control ..................................................................................... 29
5-1. Logging on or off the WTS .........................................................................29
6. USING THE TERMINAL PROPERTIES ................................................ 35
6-1. General .......................................................................................................36
6-2. Display........................................................................................................37
6-3. Control Panel..............................................................................................38
6-6. ICA Settings (ICA Protocol only)................................................................46
6-7. Server..........................................................................................................47
6-8. Security .......................................................................................................48
6-9. System.........................................................................................................50
7. SOFTWARE UPDATING/INSTALLATION ............................................ 51
8. PRACTICAL SETUP ............................................................................. 55
8-1. SC1 settings ................................................................................................55
8-2. Short cut command by keyboard ................................................................58
9. TROUBLESHOOTING........................................................................... 59
10. CLEANING.......................................................................................... 60
11. SPECIFICATIONS ............................................................................... 61
4
TABLE OF CONTENTS
4

1. INTRODUCTION

g
k
Thank you very much for purchasing the EIZO eClient SC1.

1-1. General Description

The SC1 is used as a thin client, which connects to the terminal service installed Windows Terminal Server (Hereafter defined WTS) as listed below and accesses applications or data provided from the WTS.
Server (WTS: Windows Terminal Server)
Microsoft Windows 2000 Server / Advanced Server / Datacenter Server Microsoft Windows Server 2003 Standard Edition / Enterprise Edition / Datacenter
Edition
Windows Terminal Server (WTS)
Networ
Output data of applications
eClient SC1
· Operation of applications
· Stora
e of data

1-2. Features

Lower TCO (Total Cost of Ownership)
Saves Space and Power Consumption
Less Heat, Less Noise
Windows CE OS-based
Serial Port for Modem/PDA (*Hayes AT compatible modem supported)
2 USB downstream ports (SC1: Standard Rev. 1.1)
Local Web Browser added as a default connection
PC card slot for modem card or LAN card
Wake on LAN supported
Network utility software, “Network Administrator Version 3.0” supported
Two installation types; EIZO Monitor mounted / Stand alone
EIZO Monitor detachable stand type
Input data from keyboard/mouse/ stylus
Display data Operation by keyboard/
mouse
1. INTRODUCTION 5
Secondary power switch (wired)

1-3. Package Contents

Please contact your local dealer for assistance if any of the listed items are missing or damaged. Please make sure that all the items listed are in the package.
SC1
Mouse (FDM-LCS1)
Power Cord
Switch Box (1.8 m)
Signal Cable (FD-C29) (50 cm)
User’s Manual
Monitor Attachment Unit: for mounting monitor *
Power Cord (50 cm): for mounting monitor*
Clamp for cables: for mounting monitor*
*1 The monitor attachment unit, the power cord, and the clamp for cables are used when
attaching a monitor in SC1. Installation of a monitor should follow the system administrator.
NOTE
A keyboard is not included. It must be purchased separately.
Please use the enclosed mouse. EIZO NANAO CORPORATION will no be held
responsible for accident or damage caused by the use of a mouse manufactured by other companies.
We recommend that you retain the original packing materials in case of future need.
1
1
1
6
1. INTRODUCTION

1-4. Controllers & Connectors

Controllers
Left View
(1) (2)
(3)
(4)
AC OUTPUT
AC INPUT
Right View
P o
w e
r S
Y N
C
OFF
ON
(5)
(1) Power Button (2) Power Indicator
Power Indicator State of the unit Blue
Off Power is off (Wake on LAN standby)
*1
[Procedure to return to the operation mode]
- Operate the mouse or keyboard.
*2
The monitor is in the power save mode when the power save function of the monitor is set.
Operation mode
Screen saver is active
No picture is displayed on the monitor
* L567 used as an example
*1
*1, *2
*3
(3) Connector for Switch Box
*3
(4) Switch Box (5) Power Supply Control Switch (POWER SYNC)
*4
3
The secondary power switch makes it easy to turn the SC1 on and off when stowed
*
away under the desk or out of reach. When the enclosed switch box is connected to the connector, it can be used as a power button. The power button on the SC1 can be used simultaneously even if the switch box is connected.
4
Please refer to pg. 12 for details on the power supply control switch (POWER
*
SYNC).
NOTE
When turning off/on the unit, leave the unit off for a few seconds before turning it on again.
Do your part to conserve energy, turn off the unit when your finished using it. Complete energy use can only be stopped by disconnecting the unit from the power supply.
1. INTRODUCTION 7
Connectors
(3)
(5)
(2)
(4)
(1)
AC INPUTAC INPUT
AC OUTPUTAC OUTPUT
P
P
o
o
w
w
e
e
r S
r S
Y
Y
N
N
C
C
OFFO
FF
ONO
N
(6)
(7)
(8)
(9)
(10)
(11)
(12)
(1) Power Supply Control Switch (POWER SYNC)…Same with (5) on P.7 (2) Power Connector(AC output) (3) Power Connector(AC input) (4) Ethernet Connector (10 Base-T, 100 Base-TX) (5) Parallel Connector (6) Headphone Connector
Microphone Connector (7) PC Card Slot (8) USB Port (Downstream) x 2 (9) DVI-I Output Connector (10) Serial Port (RS-232C) (11) Mouse Connector
Keyboard Connector
1
(12) Security Lock*
1
This allows for connection of a security cable. This lock supports Kensington’s
*
MicroSaver security system. For further information, please consult: Kensington Technology Group 2855 Campus Drive, San Mateo, CA 94403 USA Tel: 800-650-4242, x3348 Intl: 650-572-2700 Fax: 650-572-9675 http://www.kensington.com
8
1. INTRODUCTION

2. CONNECTING the eClient SC1

This chapter explains how to connect the eClient SC1 to a WTS.

2-1. Setting up the eClient SC1

Please observe the following cautions when connecting the SC1.
WARNING
Place the eClient SC1 on a strong, stable surface.
A unit placed on an inadequate surface may fall, resulting in injury or equipment damage. If the unit falls, disconnect the power immediately and have the unit checked by a qualified service engineer before using it again. Using a unit after it has been dropped may result in fire or electric shock.
Set the unit in an appropriate location.
Not doing so may result in fire, electric shock, or equipment damage.
*
Do not place outdoors.
*
Do not place in the transportation system (ship, aircraft, trains, automobiles, etc.)
*
Do not place in a dusty or humid environment.
*
Do not place in a location where the steam comes directly on the screen.
*
Do not place near heat generating devices or a humidifier.
The Monitor Attachment Unit supports only EIZO L767, L567, L557, L367.
Mounting other monitors to the unit may result in injury or equipment damage. Contact your system administrator for details of the attachment.
* The illustrated monitors in this section are L567. Monitors
are not included in the package.
Maximum load capacity of AC outlet is 2 A.
Connecting unit with more than 2 A may result in fire, electric shock or other damage.
OK
2. CONNECTING the eClient SC1
9
Mounting EIZO monitor to the SC1
When using other monitors than EIZO, proceed to step 3.
The Monitor Attachment Unit of SC1 supports the EIZO L767, L567, L557, and L367, so EIZO monitor mounted SC1 is available.
NOTE
Prepare the following, when mounting a monitor to the SC1.
Monitor L767, L567, L557, L367 Screws The screws used for the monitor original stand Power Cord Power Cord (50 cm) which is included into the SC1 package.
Mounting EIZO monitor procedure
Step
1.
Attach the monitor attachment unit to the monitor.
Step 1
Monitor Attachment Unit
Step 2
AC OUTPUTAC OUTPU
A
A
C
C
IN
IN
P
P
U
U
T
T
Step
P
P o
o
w
w e
e
r
r S
S
Y
Y
N
N
C
C
O
O
F
F F
F
ONO
N
P
P O
O
O
O Q
Q
|
| O
O
P
P O
O
Q
Q |
|
O
O Q
Q
u
u S
S
‘ O
O
Q
Q
u
u
‘ ‘
Q
Q
T
2.
Mount the monitor to the SC1.
1.
Attach the monitor attachment unit to the monitor.
(1) [1] Hold the center of the cover of the monitor attachment unit (upper side and
bottom side) and [2] slide them rightward or leftward to remove the covers.
[2]
[1]
10
2. CONNECTING the eClient SC1
[2]
[1][1]
(2) Lay the LCD monitor down on the soft cloth or cushion not to scratch the panel
surface.
(3) Remove the original stand by loosening the screws.
(4) Attach the monitor attachment unit to the monitor securely, by using the screws,
which used for the original stand.
100 mm x 100 mm For L567, L557, L767
75 mm x 75 mm For L367
(5) Get back the cover to the monitor attachment unit.
2.
Mount the monitor to the SC1.
(1) Fit the protruding portion of the monitor attachment unit (4 points) to the
attachment position of SC1 (4 points), and insert it in downward, by pressing down the knob of the monitor attachment unit into the knob position of SC1.
NOTE
Monitor mount positions SC1 has three attachment position (Highest position, Middle position and lowest position). Please be sure to attach in each position as follows.
Refer to the P. 62 for the dimensions figure according to monitor size.
Knob position
Middle position
(2) Grip both side of the monitor firmly with both hands and adjust the monitor angle
as desired.
Highest position
Lowest position
2. CONNECTING the eClient SC1
11
Connecting the signal cable and power cables
3.
Plug the signal cable into the connector at the rear of the monitor and the other end of the cable into the video connector on the DVI-I connector of the SC1
4.
After connecting, secure the connection with the screw-in fasteners.
5.
Plug the power cord (50 cm), included into the package, into the power connector on the rear of the monitor and the other end of the cable into the power connector (AC outlet) of the eCleint, or into a power outlet.
WARNING
Use the enclosed power cord and connect to the standard power outlet of your country.
Be sure to remain within the rated voltage of the power cord. Not doing so may result in fire or electric shock.
The equipment must be connected to a grounded main outlet.
Not doing so may result in fire or electric shock.
Maximum load capacity of AC outlet is 2 A.
Connecting unit with more than 2 A may result in fire, electric shock or other damage.
Power Supply Control Switch (POWER SYNC)
When the monitor's power cord is connected to the AC output power supply of SC1, the monitor’s power supply can be linked with on/off of SC1. Choose ON from the power supply control switch (POWER SYNC).
When the power button of SC1 is turned on or off…
Power Supply Control Switch (POWER SYNC)
ON The monitor’s power supply is linked, and it turns on or
OFF (default) Since the monitor’s power supply is not linked, please
Power supply for the monitor
off simultaneously.
turn the monitor's power supply on or off independently.
12
2. CONNECTING the eClient SC1
NOTE
Bundling cables After all connection has been made, please bundle the cables with the clamp included into the package, so that the cables do not obstruct the paths as follows.
Clamp installation
Power SYNCPower SYNC
OFFOFF
ONON
P
P
O
O
O
O Q
Q
|
| O
O
P
P
AC OUTPUTAC OUTPUT
O
O
Q
Q |
|
O
O Q
Q
u
u S
S
‘ O
O
Q
Q u
u
‘ ‘
Q
Q
A
A
C
C
IN
IN
P
P
U
U
T
T
Connecting the peripheral devices to SC1
NOTE
Before connecting the SC1, confirm the following:
- The SC1 is turned off.
- The WTS is turned on.
Connect the peripherals to the appropriate connectors of the unit.
6.
In case of connecting the WTS through LAN: Connect the SC1 to the network with an Ethernet cable.
In case of a dial-up or dial-in connection: Connect the SC1 to a modem or a modem card.
NOTE
Please remove the lid on the side of the SC1 before connecting a LAN card or a modem card.
7.
Plug a keyboard and a mouse into the SC1.
8.
When using other devices, connect them to the appropriate connectors.
2. CONNECTING the eClient SC1
13
9.
The switch box is connected to the attached connector on the SC1 if needed.
The secondary power switch makes it easy to turn the SC1 on and off when stowed away under the desk or out of reach. When the switch box is connected to the connector, it can be used as a power button. The power button on the SC1 can be used simultaneously even if the switch box is connected.
10.
If using other devices, please connect them to the appropriate
connectors.
11.
Plug the power cord into the power connector.
If the power cord is connected to a power supply wall socket, regardless of ON or OFF operation of the power button, the SC1 will starts up.
NOTICE
Note that the SC1 also starts up whenever electric power is intercepted from power failure or master power shutdown, and power supply is restored after that.
WARNING
Use the enclosed power cord and connect to the standard power outlet of your country.
Be sure to remain within the rated voltage of the power cord. Not doing so may result in fire or electric shock.
The equipment must be connected to a grounded main outlet.
Not doing so may result in fire or electric shock.
NOTE
The screen, which SC1 can display, is as follows.
Analog Output Digital Output
640 x 480 @60 Hz
800 x 600 @60 Hz
1024 x 768 @60 Hz
1280 x 1024 @60 Hz
14
2. CONNECTING the eClient SC1
8 bbp 8 bbp 16 bbp 16 bbp 32 bbp 8 bbp 8 bbp 16 bbp 16 bbp 32 bbp 8 bbp 8 bbp 16 bbp 16 bbp 32 bbp 8 bbp 8 bbp 16 bbp 16 bbp
32 bbp
640 x 480 @60 Hz
32 bbp
800 x 600 @60 Hz
32 bbp
1024 x 768 @60 Hz
32 bbp
1280 x 1024 @60 Hz
32 bbp

3. SETTING UP the eClient SC1

This chapter presents how to prepare for a connection with a WTS when the eClient SC1 starts up for the first time.
1.
Turn on the eClient SC1.
The power indicator turns green and a picture appears on the screen.
NOTE
When no picture is displayed, or when the message (No keyboard connected. / No mouse connected.) is shown on the screen, please refer to “8. Troubleshooting” on page 59.
2.
“eClient Setup Wizard” is displayed.
(Set up the SC1 according to directions of the displayed dialog box.)
3. SETTING UP the eClient SC1
15
3.
End User License Agreement page is displayed.
Read the content and click [Accept] to continue.
16
3. SETTING UP the eClient SC1
4.
Set up the network environment.
[Terminal Name] ................Type the name to identify this unit on the network.
Click [Network Properties] and set up connection information according to the connection method to WTS/Web server.
Connection method Reference page
In case of connecting the WTS/Web through Built-in LAN
In case of connecting with a NE2000 compatible LAN card:
In case of connecting with a Cisco wireless LAN card/ Agere wireless LAN card:
In case of a dial-up connection:
In case of the dial-in connection (ICA protocol only) to log on to WTS
NOTE
eClient
[Dial-Up Connection] [Dial-In Connection]
Telephone Lines
RAS Server
WTS FTP Server
p.18
p.18
p.19
p.20
Go to step 5
* Skip the [Network
Properties] settings
Telephone Lines
WTS
eClient
3. SETTING UP the eClient SC1
17
Example; In case of connecting with a
NE2000 compatible LAN card
In case of connecting the WTS/Web through Built-in LAN:
(1) Double-click [Built-in LAN] icon.
[IP Address] ........................Type the IP address of the unit.
[Name Servers]....................Type the IP address of each server when DNS or
WINS is used.
[Advanced]..........................Type the transmission speed and MAC Address of a
network.
In case of connecting with a NE2000 compatible LAN card:
(1) Double-click [NE 20001] icon.
[IP Address] ........................Type the IP address of the unit.
[Name Servers]....................Type the IP address of each server when DNS or
WINS is used.
18
3. SETTING UP the eClient SC1
In case of connecting with a Cisco wireless LAN card/Agere wireless LAN card:
(1) Double-click [CISCO1]/[WLAGS461] icon.
[IP Address] ........................Type the IP address of the unit.
[Name Servers] ...................Type the IP address of each server when DNS or
WINS is used. [Wireless Networks]
...................................Set the connection setting with a wireless LAN card.
NOTE
In case of selecting [Obtain an IP address via DHCP], deactivate the built-in
LAN by the procedure below.
(1) Richt-click [Built-in LAN] icon (2) Select [Disable] in the displayed dialog.
3. SETTING UP the eClient SC1
19
Loading...
+ 44 hidden pages