4-2
EK-600U/EK-601W
4-3 Auto Waveform and Fan Calibration
After replacing main board, fan, or upgrading the firmware, please follow
steps as below:
1.Hold “power”key, then Plug in the power cord.Plug in the power cord.
2.Release the “power” key until the “power” LED flashed red 2s
to enter into auto waveform fan calibration.
3.When waveform download and Fan calibration is complete,the
projector power on automatically.
Note:- If the factory fan value don’t show in service mode,
please repeat the step 1,2 again.
- Make sure the “Blower Factory RPM “is 1705~2307.
4-4 Keystone Calibration
Procedure - Please put the projector on a horizontal surface.
- Please press "power", “up”,”right”,
“up”,”left”,”menu”, buttons sequentially
to get into service mode.
- Choose "Clibration" , press "Enter" button
then choose “Auto Keystone Calibration”
- Test the projected image under 30 degree
Inspection item - the projected screen
Criteria - Automatically adjust the shape of the projected
image according to the angle at which the projector
is positioned.