EEMAX “SERIES-TWO” WATER HEATERS
ELECTRIC INSTANTANEOUS WATER HEATER
INSTALLATION GUIDE AND OWNERS MANUAL
MODELS COVERED:- EX190 TC, T2 - 240/208 V
EX144 TC, T2 - 240/208 V
EX1608 TC, T2 – 208V
EX160 TC, T2 - 277 V
EX200 TC, T2 - 277 V
WARNING
READ THE GENERAL SAFETY SECTION BEGINNING ON THE INSIDE COVER
AND THEN THIS ENTIRE MANUAL BEFORE INSTALLING OR OPERATING THIS
WATER HEATER. IF YOU DON’T FOLLOW THE SAFETY RULES, THE UNIT WILL
NOT OPERATE PROPERLY AND IT COULD CAUSE DEATH, SERIOUS BODILY
INJURY AND/OR PROPERTY DAMAGE. READ ALSO THE ENCLOSED
WARRANTY CARD. WARRANTY OF THIS WATER HEATER WILL DEPEND ON
PROPER INSTALLATION AND OPERATION. THE WARRANTY SHALL BE VOID IF
THE DESIGN HAS BEEN ALTERED IN ANY WAY WHATSOEVER. THE
MANUFACTURER OF THIS HEATER WILL NOT BE LIABLE FOR ANY DAMAGES
BECAUSE OF FAILURE TO COMPLY WITH THE INSTALLATION AND
OPERATING INSTRUCTIONS OUTLINED ON THE FOLLOWING PAGES.
THE INSTALLATION MUST CONFORM WITH THE INSTRUCTIONS IN THIS
MANUAL; ELECTRIC COMPANY RULES; AND THE LOCAL CODES, OR IN
THE ABSENCE OF LOCAL CODES, WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE. THIS PUBLICATION IS AVAILABLE FROM
YOUR LOCAL GOVERNMENT OR PUBLIC LIBRARY OR ELECTRIC COMPANY
OR BY WRITING UNDERWRITERS LABORATORIES, 333 PFINGSTEN ROAD
NORTHBROOK, IL, 60062.
IF YOU REQUIRE ANY HELP OR HAVE ANY QUESTIONS RELATING TO THE
INSTALLATION OR PERFORMANCE OF THIS HEATER, PLEASE CALL OUR
TECHNICAL SERVICE DEPARTMENT TOLLFREE : 1-800-543-6163.
HAVE THE INFORMATION LISTED BELOW BEFORE CALLING :
SERIAL NO. MODEL NO. EX INSTALLATION DATE
1
seriestwo092608.ppt
GENERAL SAFETY
The “Eemax Series Two” heater is specifically designed to take in cold water and heat it to
temperatures suitable for normal domestic usage up to a maximum of 140 F (60 C). To
obtain optimum performance and energy savings, the unit should be located as near as
possible to the point of use.
The unit is supplied with 3/4” NPT pipe connections. Under no circumstances use a blow
torch on pipe which is connected to the heater (serious damage to the electronic flow
switch will result). Carefully use Teflon tape, ensuring no debris enter the heater. Do not
use pipe dope.
Also, ensure that the pipes are clear of installation debris before fitting the heater.
THIS HEATER MUST HAVE TWO DEDICATED INDEPENDENT
CIRCUITS, USING CORRECTLY RATED WIRES AND CIRCUIT
BREAKERS.
WARNING
FAILURE TO GROUND THE SYSTEM MAY RESULT IN DEATH OR SERIOUS INJURY.
WARNING
IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE OR MAINTENANCE
CAN CAUSE DEATH, SERIOUS BODILY INJURY OR PROPERTY DAMAGE. REFER TO
THIS MANUAL FOR ASSISTANCE OR CONSULT THE LOCAL ELECTRIC UTILITY FOR
FURTHER INFORMATION.
WARNING
WATER HEATERS EQUIPPED FOR ONE VOLTAGE ONLY: THIS WATER HEATER IS
EQUIPPED FOR ONE VOLTAGE TYPE ONLY: CHECK THE RATING PLATE ON THE FRONT
COVER OF UNIT FOR THE CORRECT VOLTAGE. DO NOT USE THIS WATER HEATER WITH
ANY OTHER VOLTAGE OTHER THAN THE ONE SHOWN ON THE MODEL RATING PLATE.
FAILURE TO USE THE CORRECT VOLTAGE CAN CAUSE PROBLEMS WHICH CAN RESULT
IN DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. IF YOU HAVE ANY
QUESTIONS OR DOUBTS CONSULT EEMAX OR YOUR ELECTRIC COMPANY.
WARNING
HAZARD OF ELECTRICAL SHOCK! BEFORE REMOVING THE COVER OR SERVICING THE
WATER HEATER, MAKE SURE THE ELECTRICAL SUPPLY TO THE WATER HEATER IS
TURNED “OFF”. FAILURE TO DO THIS COULD RESULT IN DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
2
MOUNTING
HOLES
MINIMUM - 8” CLEARANCE ABOVE UNIT
10 ½’’
RELAY LUGS
ELECTRICAL
HOOK-UP
240/208 V
L 1 L2 L1 L2
RELAY LUGS
ELECTRICAL
HOOK-UP
277 V
10’’
4”
Outlet isolating valveball valve (leave open
just enough to obtain
adequate flow of hot water)
L N L
N
ground
Two independent circuit breakers
Inlet isolating valve-
ball valve. (Always leave fully
open when unit is in service.)
Figure 1
3
I. MOUNTING THE UNIT
1) The unit should be mounted as close to the point of use as possible. For example, directly
beneath the sink is ideal.
Do not install the heater above a faucet or “point of use” because the siphoning effect may
drain the heater which can cause premature element burn out.
2) This unit must only be mounted in a vertical position with the water fittings located at the
bottom of the unit. Mounting other than in the vertical position WILL cause element burn
out and cause permanent damage to the water heater.
3) The cold water inlet is on the right hand side and the hot water outlet is on the left hand side.
Under NO circumstances can these be reversed.
4) Leave a minimum of 8” above the unit for easy replacement of the element.
5) The heater should be fixed to the wall using screws in the four mounting holes at each corner
of the backplate.
NOTE: The heater should be installed below the level of all hot water outlets serviced by this
heater.
NOTE: PRESSURE AND TEMPERATURE RELIEF VALVE
These units are not required by UL to have a Pressure and Temperature Relief
Valve (PTRV). You should check with local codes to find out if one is required in your
area.
If local codes require the use of a temperature and pressure relief valve it should be
installed on the outlet hot water pipe before the outlet ball valve.
Figure 2
Installation directly beneath the
sink is ideal
Hot
EemaX
4
Cold
TO SHOWER
HOT OUTLET COLD INLET