Eemax EX144TC, EX144TC S, EX144TC ML, EX144TC FS, EX190TC User Manual

...
Series Two™, "TC"
In USA
Assembled
Staged Models (Two Heating Modules) with Thermostatic Control
Single or multi-xture
Commercial/Industrial
Adjustable temperature setting with +/–1°F temperature stability
Solar backup with FS option
Performance Features
Turns on in stages based on hot water demand
On demand hot water
Continuous hot water. No storage capacity to run out
Reduces installation cost and material. No T&P relief valve needed (check local codes) or venting
Easy installation with integral 3/4" NPT ttings
Cut energy waste. Flow switch activates heater only on demand (no standby heat loss)
Two glass-ber reinforced heater bodies and nichrome elements – a unique, patented ow path ensures optimum heat transfer and extended element life
Warranty, ve (5) years limited on leaks, one (1) year parts
Field serviceable replaceable cartridge element
Unit mounts on wall
High temperature limit switch
Optional Features
Factory set ambient to 180°F (FS)
Multi lavs 0.3 turn on. Staged up to 4 lavs 105°F-110°F temp setting (ML)
Sanitation 180°F (S)
N4, N4X (304SS) enclosures
Product Specications
Dimensions: 10.25" x 10.75" x 4.5"
Weight: 10.5 lb
Cover: Enameled steel
Color: White
Element: Dual replacement cartridge inserts
Thermostatic control (+/-1°F) accuracy at steady
state
Fittings: 3/4" NPT ttings at bottom of unit
Min. Dynamic Operating Pressure: 40 PSI
Max. Dynamic Operating Pressure: 150 PSI
UL listed le number: E86887
U.S. Patent #'s: 4,762,980 and 4,960,976
Suggested Specication
Tankless water heater shall be an Eemax Series Two model number EX_________________________.
Heater shall have two heating modules. Element shall be replaceable cartridge insert. Unit shall have a replaceable lter in the inlet connector. Heater shall be tted with 3/4" NPT water connections. Maximum operating pressure of 150 PSI. Hot water storage tanks prohibited. Unit shall be Eemax or approved equal. NOTE: Refer to rating chart for product information.
Enclosure to be tted with the following features:
_____ FS Factory set ambient to 180°F _____ ML Multi lavs 0.3 turn on. Staged up to
_____ S Sanitation 180°F _____ N4 NEMA 4 steel cabinet with powder coat nish _____ N4X NEMA 4 stainless steel, corrosion-resistant cabinet
*The wetted surface of this product contacted by water contains less than
0.25% lead and meets NSF/ANSI 372
4 lavs 110°F temp setting
Specications
Tankless Electric Water Heater
Special Design Service
Inquiries for units for unique applications are welcome. Call our Technical Service department at 1-800-543-6163.
Information and product specications contained in this document are subject to change without notice. REV 2020-01
21
Series Two, "TC"
10.68
10.12
20.00
1.97
8.78
NEMA 4/4X
Staged Models (Two Heating Modules) with Thermostatic Control
Specications
Tankless Electric Water Heater
Sux Denitions
FS Factory set ambient to 180°F ML Multi lavs 0.3 turn on. Staged up
S Sanitation 180°F
4.32
18.50
to
4 lavs 105°F-110°F temp setting
UTLET
1.77
1.41
4.00
.94
OUTLET
2.80
4.07 4.00
INLET
ELECTRICAL CONNECTION (2)
16.00
14.50
4XØ .500
MOUNTING HOLES
INLET
MODEL NUMBER
VOLTS 240*
C
EX144TC
C
EX144TC (derated 208V performance)
C
EX144TC S
C
EX144TC ML
C
EX144TC FS
C
EX190TC
C
EX190TC (derated 208V performance)
C
EX190TC S
C
EX190TC FS
C
EX190TC ML
EX023240TC
EX023240TC (derated 208V performance)
EX023240TC S
EX023240TC FS
EX023240TC ML
VOLTS 208 Single Phase
C
EX1608TC
C
EX1608TC S
C
EX1608TC FS
C
EX1608TC ML
VOLTS 277
EX160TC
EX160TC S
EX160TC FS
EX160TC ML
EX200TC
EX200TC S
EX200TC FS
EX200TC ML
CNL Models
C
EX144TC CNL
C
EX144TC S CNL
C
EX144TC FS CNL
C
EX144TC ML CNL
C
EX190TC CNL
C
EX190TC S CNL
C
EX190TC FS CNL
C
EX190TC ML CNL
C
EX1608TC CNL
C
EX1608TC S CNL
C
EX1608TC FS CNL
C
EX1608TC ML CNL
* 240V units can be used on 208V single phase with 25% reduced temperature output. Please note per UL standards the rating plate and installation instructions will all be according
to a 240V applied voltage. Check with local ofcials prior to derating the electrical infrastructure.
"C" indicates evaluation and compliance to either Underwriters Laboratories (UL) or Intertek (ETL) under CAN/CSA-C22.2 No. 64/No. 88. CNL SKUs are Canada specic.
kW AMPS
15.0 64(2x32) 10 AWG 0.7 3.0 68° 51° 41° 34°
11.2 54(2x27) 10 AWG 0.7 3.0 51° 38° 31° 25°
15.0 64(2x32) 10 AWG 0.7 3.0 68° 51° 41° 34°
15.0 64(2x32) 10 AWG 0.3 3.0 68° 51° 41° 34°
15.0 64(2x32) 10 AWG 0.7 3.0 68° 51° 41° 34°
19.0 80(2x40) 8 AWG 0.7 3.0 87° 65° 52° 43°
14.0 68(2x34) 8 AWG 0.7 3.0 64° 48° 38° 32°
19.0 80(2x40) 8 AWG 0.7 3.0 87° 65° 52° 43°
19.0 80(2x40) 8 AWG 0.7 3.0 87° 65° 52° 43°
19.0 80(2x40) 8 AWG 0.3 3.0 87° 65° 52° 43°
23.0 96(2x48) 8 AWG 0.7 3.0 105° 79° 63° 52°
17.3 83(2x50) 8 AWG 0.7 3.0 79° 59° 47° 39°
23.0 96(2x48) 8 AWG 0.7 3.0 105° 79° 63° 52°
23.0 96(2x48) 8 AWG 0.7 3.0 105° 79° 63° 52°
23.0 96(2x48) 8 AWG 0.3 3.0 105° 79° 63° 52°
16.6 80(2x40) 8 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 8 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 8 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 8 AWG 0.3 3.0 76° 57° 45° 38°
16.0 58(2x29) 10 AWG 0.7 3.0 73° 55° 44° 36°
16.0 58(2x29) 10 AWG 0.7 3.0 73° 55° 44° 36°
16.0 58(2x29) 10 AWG 0.7 3.0 73° 55° 44° 36°
16.0 58(2x29) 10 AWG 0.3 3.0 73° 55° 44° 36°
20.0 72(2x36) 8 AWG 0.7 3.0 91° 68° 55° 46°
20.0 72(2x36) 8 AWG 0.7 3.0 91° 68° 55° 46°
20.0 72(2x36) 8 AWG 0.7 3.0 91° 68° 55° 46°
20.0 72(2x36) 8 AWG 0.3 3.0 91° 68° 55° 46°
15.0 64(2x32) 6 AWG 0.7 3.0 68° 51° 41° 34°
15.0 64(2x32) 6 AWG 0.7 3.0 68° 51° 41° 34°
15.0 64(2x32) 6 AWG 0.7 3.0 68° 51° 41° 34°
15.0 64(2x32) 6 AWG 0.3 3.0 68° 51° 41° 34°
19.0 80(2x40) 4 AWG 0.7 3.0 87° 65° 52° 43°
19.0 80(2x40) 4 AWG 0.7 3.0 87° 65° 52° 43°
19.0 80(2x40) 4 AWG 0.7 3.0 87° 65° 52° 43°
19.0 80(2x40) 4 AWG 0.3 3.0 87° 65° 52° 43°
16.6 80(2x40) 4 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 4 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 4 AWG 0.7 3.0 76° 57° 45° 38°
16.6 80(2x40) 4 AWG 0.3 3.0 76° 57° 45° 38°
RECOMMENDED
WIRE SIZE
(75° C/CU)
TURN ON
(GPM)
MAX FLOW
(GPM)
1.5
GPM
TEMPERATURE RISE °F
2.0
GPM
2.5
GPM
3.0
GPM
22