The 125XBRi Series Chameleon Multi-Status LED Indicator
is a UL and cUL listed, multi-color LED signaling appliance
in a NEMA 4X rated enclosure. The indicator can be panel
or conduit mounted. A protective guard, Cat. No. 125GRD,
is also available.
The lights are available in 24V DC and 120V 50/60 Hz. They
are available in either Red/Blue/Amber or Red/Green/Amber.
Edwards Signaling's NEW 125XBRi Multi-status Indicator
is more "chameleon-like" than ever. With our new adaptive
design - one device does it all. With a quick change to the
new 125 Chameleon's dip switch settings, these exible
multi-status indicators instantly adapt for use with or without
control from an external PLC, PAC, or control relay. Now,
regardless of the application you will have just the right device
for the job with only half the inventory.
XTRA-SAFE Enabled
The Chameleon 125XBRi devices ship as standard with
Edwards Signaling's XTRA-SAFETM Technology (patent
pending) Enabled. XTRA-SAFE multi-status indicating
devices employ patented combinations of color AND ashrate to provide more denite status indication to those who
are color-blind. With XTRA-SAFE, when Chameleon multistatus indicators are turned red, they pulse at a rate of 240
ashes per minute, further emphasizing the urgency which
the color red typically connotes. When amber, these devices
pulse at a "less urgent" rate of 120 ashes per minute. When
Chameleon multi-status indicators are turned blue or green
and no other colors are energized, the Chameleon devices
remain "steady-on" and do not ash. Even in extreme cases
where no color is perceived, ash-rate variation provides a
redundant layer of visual indication.
When XTRA-SAFE Technology is enabled, and multiple colors are energized, the device will cycle through the energized
colors at the following pre-set ash-rates:
the unit pulses at a rate of 65 ashes per minute. When
Chameleon multi-status indicators are turned green or blue
and no other colors are energized, the Chameleon devices
remain "steady on" and do not ash.
When XTRA-SAFE Technology is disabled, and multiple colors are energized, the device will cycle through all energized
colors at 65 FPM.
Externally Controlled
The Chameleon multi-status indicators can also be used in
applications where they will be controlled "externally" using a
Programmable Logic Controller (PLC) or other such external
controller. When externally controlled by a PLC, activation
of colors and ash-rate are fully customizable, and can be
programmatically determined. In applications, where multiple
colors are activated simultaneously, the lights operate on a
priority with red highest, amber second and blue or green,
the lowest. Refer to Figure 1 (Applications WITH a separate
PLC or Controller).
Wire color corresponds with each indicated color.
Red wire = Red LED's
Yellow wire = Amber LED's
Blue with Green tracer wire = Green or Blue LED's
Electrical Specications
GRAY BASEBLACK BASE
Catalog NumberCatalog NumberElectrical Specs
Red, Green, Amber
125XBRiRGA24D125XBRiRGA24DB24V DC, 0.150A
125XBRiRGA120A125XBRiRGA120AB120V AC*, 0.100A
Red, Blue, Amber
125XBRiRBA24D125XBRiRBA24DB24V DC, 0.150A
125XBRiRBA120A125XBRiRBA120B120V AC*, 0.100A
* 120V AC 50/60 Hz
Red: 240 FPM
Amber: 120 FPM
Green or Blue: 65 FPM
XTRA-SAFE Disabled
While in most cases, the added layer of safety gained by operating a multi-status indicator with XTRA-SAFE Technology
is desirable, some applications may not require differentiation
in ash rates. In other applications, changes do not correspond to escalating levels of urgency. The adaptive design
of the new Chameleon 125 XBRi allows the product to be
adapted to accommodate these requirements by conguring
the dipswitches as shown in Figure 1 (Applications WITHOUT a separate PLC or Controller - XTRA-SAFE Technology
Disabled). With XTRA-SAFE Disabled, when red or amber,
Mechanical Specications
Outdoor Locations
Temperature Ratings ...........-31F to +150F (-35C to +66C)
1. Remove (4) screws securing the lens to the base from
bottom of base (Figure 2) and remove lens.
WARNING
To prevent electrical shock, ensure that power
is turned off before installing the signal.
The 125XBRi Multi-Status indicator is shipped with XTRASAFE Technology Enabled. The unit offers two other eld
selectable options: (1) for applications without a separate
PLC or controller with the XTRA-SAFE Technology disabled
or (2) for applications with a separate PLC or controller. For
more information on the features, refer to the description.
For settings, refer to Figure 1.
XTRA-SAFE Enabled
WARNING
To avoid risk of injury, install lens before
energizing the unit and do not remove or
insert light source when unit is energized.
- Applications without a separate PLC or Controller
- XTRA-SAFE Technology Disabled: Set dipswitch
SW1 to the OFF position and SW2 to the ON
position.
XTRA-SAFE Disabled
- Applications with a separate PLC or Controller - Set
dipswitches SW1 and SW2 to the OFF position.
With a PLC or other External Controller
2. Replace lens on base and secure with (4) screws
removed in step 1.
Lens
Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Enabled
(Factory Default)
*It is generally recommended that both dipswitches, SW1 and SW2,
be set to OFF for applications using an external Programmable Logic
Controller (PLC) or other external controller. A PLC or controller, however, can be used with any of the shown configurations.
Applications WITHOUT
a PLC or Controller* XTRA-SAFE Technology
Disabled
Figure 1. Dipswitch Settings
Applications WITH
a PLC or Controller*
O-Ring (in groove)
(supplied)
Base
(4) Screws securiing
lens to base
Figure 2. Removing the Lens
Table 2. PLC Compatibility
GRAY BASEBLACK BASE
Catalog NumberCatalog NumberOperating
Voltage (Volts)
125XBRiRGA24D125XBRiRGA24DB24V DC515028.5/65
125XBRiRBA24D125XBRiRBA24DB
125XBRiRGA120A125XBRiRGA120AB120V AC 50/60 Hz510028.5/212
Note: When panel mounting these beacons, the surface
and construction details of the panel must be
WARNING
To avoid risk of injury, install lens before
energizing the unit.
taken into consideration in order to ensure that the
integrity of the outdoor, NEMA 4X rating is fully
maintained. Installer should evaluate.
1. Thread the 18" (457 mm) signal wire leads through either
1/2" or 3/4" conduit into an approved conduit outlet box.
(Product is supplied with a double threaded - 1/2" internal
and 3/4" external - conduit hub.)
WARNING
To prevent electrical shock, disconnect power
before removing the lens.
2. Thread the conduit onto the base of the signal.
(Blue or Green LED activation)
DC Units; Blue with green stripe, Positive (+)
AC Units; Blue with Green stripe, Hot
1. Place the mounting gasket (supplied) over the hole in
the panel and route the signal wires through the gasket
and the hole in the panel.
2. Insert the base through the hole in the panel and screw
the locking nut (supplied), with the raised locking edge
facing the mounting surface, onto the base to secure
the beacon.
125XBRI Series Chameleon
LED Visual Indicator
3/4" (19 mm) NPT
conduit (not supplied)
DC Units; Black DC common (-)
AC Units; White AC neutral
(Red LED activation)
DC Units; Red Positive (+)
AC Units; Red Hot
(Amber LED activation)
DC Units; Amber Positive (+)
AC Units; Amber Hot
Wire Nuts
(not supplied)
Figure 3. Conduit Mounting (3/4" Shown)
Locking Nut -
1.3625" OD
(supplied)
Control panel
Wire nuts
(not supplied)
DC Units; Black DC common (-)
AC Units; White AC neutral
Figure 4. Panel Mounting
Power source wires
125XBRI Series Chameleon
LED Visual Indicator
Gasket
(supplied)
(Blue or Green LED activation)
DC Units; Blue with green stripe, Positive (+)
AC Units; Blue with green stripe, Hot
(Red LED activation)
(DC Units; Red positive (+)
AC Units Red Hot
(Amber LED activation)
DC Units; Amber Positive (+)
AC Units; Amber Hot
P/N 3101611 ISSUE 3
Page 4
Wiring (Refer to Figures 3 and 4)
Maintenance
AC models
1. There are four 18" wire leads: white (neutral), red
(for activation of red LEDs), blue with green stripe (for
activation or green or blue LEDs--depending on model)
and amber (for activation of amber LEDs).
Using wire nuts, connect white lead to AC neutral and
connect each of the other three leads to AC hots.
DC models
1. There are four 18" wire leads: black (negative), red
(for activation of red LEDs), blue with green stripe (for
activation of green or blue LEDs--depending on model)
and amber (for activation of amber LEDs).
Using wire nuts, connect black lead to DC negative and
connect each of the other three leads to DC positives.
2. Turn on power and verify that the signal operates
properly.
Cleaning
The module lens exterior surfaces should be periodically
cleaned with a soft clean cloth using water and a mild detergent to maintain optimum light visibility. Disconnect power
before cleaning.
Lens Replacement
1. Remove (4) screws securing the lens to the base from
bottom of base and remove lens.
2. Replace lens on base and secure with (4) screws
removed in step 1 (Figure 2).