FIRE ALARM EQUIPMENT
Genesis® Chimes &
Chime/Strobes
Multi-Candela, Multi-Watt,
Field Configurable
EG1*-C & EG1*-CVM Series
FEATURES
> Unique low-profile design
> Attractive appearance
> Ultra-slim - protrudes les than
one inch from wall
®
> FullLight
Strobe Technology
> Low current draw
> 15/30/75/110 candela output
> Select non-coded (default),
temporal, or coded (single-stroke)
chime operation
> Single microprocessor controls
both chime and strobe
> Select high (default) or low dB
chime output
> No visible mounting screws
AGENCY APPROVALS
> UL 1971 Listed for the hearing
impaired
> UL 1638 Listed as protective
visual signaling appliances
> UL 464, CE, FCC
> MEA, FM, CSFM pending
*Standard models in white. Insert "R"
for red, "F" for white with fire marking,
"RF" for red with fire marking.
D-04
The Genesis line of signals are the smallest, most compact au-
dible-visible emergency signaling devices in the world. Genesis
chimes and chime strobes blend with any decor and feature tex-
tured housings in neutral white or traditional fire alarm red.
Genesis strobes do not require bulky specular reflectors. Instead,
an exclusive mask-and-cavity design channels and conditions light
to produce a highly controllable distribution pattern. Intensive devel-
opment efforts employing this new technology have given rise to a
new benchmark in strobe performance – FullLight
technology produces a smooth light distribution pattern without the
spikes and voids characteristic of specular reflectors. This ensures
the entire coverage area receives consistent illumination from the
strobe flash.
Genesis strobes are self-synchronizing, but when installed with an
optional synchronization module, strobe flashes from devices on
the same circuit synchronize to within 10 milliseconds of each other
indefinitely. Chime/Strobes feature 15, 30, 75 or 110 candela output,
selectable with a conveniently-located switch on the bottom of the
device. Settings are clearly visible even after installation.
Genesis chimes produce a pleasing mellow tone. When steady
(non-stroked) voltage is applied, the chime automatically pulses at
60 strokes per minute, or may be field-configured for temporal out-
put. When installed with a EG1M Signal Master Module, the chime
may also be field-configured for coded operation, which enables the
chime output to match the rate that voltage is applied to the circuit.
The chime’s 79 dBA (peak) output level makes this device suitable
for many private mode applications. Chimes may be set for low dB
output with a jumper cut that reduces sound output by about 5 dB.
®
technology. This
12-28
© Copyright 2004 Edwards
TECHNICAL INFORMATION
FIRE ALARM EQUIPMENT
2 3/4”
(70mm)
4 1/2”
(114mm)
GENESIS CHIMES & CHIME/STROBES
Housing Red or white textured UV stabilized, color impregnated engineered plastic. Exceeds 94V-0 UL flammability rating.
Lens Optical grade polycarbonate
Mounting Flush: 2 1/2" (64mm) deep one-gang box
(indoor wall mount only) Surface: Edwards model 27193 surface mount box, wiremold box, or equivalent surface-mount box
With optional trim plate: One-gang, two-gang, four-inch square, octagonal, or European single-gang box
Wire Connections Screw terminals: separate polarized inputs for speaker & strobe, #18 to #12 AWG (0.75 mm2 to 2.5 mm2) wire size
Operating Environment 32-120° F (0-49° C) ambient temperature; 93% relative humidity.
Agency Approvals UL1971, UL1638, UL464, CE, FCC, (MEA, FM, CSFM pending).
(All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule).
Operating Voltage EG1-C Series chimes: Non-coded, filtered 16-33V DC or unfiltered 16-33V DC FWR
(or coded when chime set to single-stroke operation)
EG1-CVM Series chime-strobes: Non-coded, filtered 16-33V DC or unfiltered 16-33V DC FWR
(or coded (audible NAC only) when used with optional EG1M Signal Master)
Strobe Output Rating UL 1971, UL 1638, selectable 15 cd, 30 cd, 75 cd, or 110 cd output
Strobe Flash Rate One flash per second (fps) with optional EG1M Signal Master indefinitely within 10 milliseconds
(or self synchronized within 200 milliseconds over 30 minutes on common circuit without EG1M).
Compatible Sync Module EG1M-RM
Chime Pulse Rate Non-coded operation - one stroke per second synchronized with optional EG1M Signal Master, indefinitely
within 10 milliseconds (or self-synchronized within 200 milliseconds over thirty minutes on a common circuit
without the EG1M Signal Master); coded operation - up to one stroke per second (EG1M Signal Master required)