Table of contents
Table of contents |
1 |
|
|
||||||||||||||||||||||||||||||||||||
Thank you |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
|||||||||||||||
Energy saving tips |
2 |
|
|
|
|
|
|||||||||||||||||||||||||||||||||
Notes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 |
|
|
|
|
|
||||||||||||||||||
Specifications |
|
3 |
|
|
|
|
|
||||||||||||||||||||||||||||||||
Safety precautions |
3 |
|
|
|
|||||||||||||||||||||||||||||||||||
Parts |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|||||||||||||||||||
|
Front view |
5 |
|
|
|
|
|
||||||||||||||||||||||||||||||||
Rear view |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5 |
|
|
|
|
|
|||||||||||||
Accessories |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 |
|
|
|
|
|
|||||||||||||
Installation |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
7 |
|
|
|
|
||||||||||||
Installing |
|
|
|
the exhaust hose |
7 |
|
|
|
|||||||||||||||||||||||||||||||
Window installation |
|
|
|
|
8 |
|
|
|
|
|
|||||||||||||||||||||||||||||
Wall installation |
|
|
|
|
|
|
|
|
|
9 |
|
|
|
|
|
||||||||||||||||||||||||
Notes |
|
|
|
|
|
|
|
|
|
|
|
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
10 |
|
|
||||||||||||||||||||||||||||
Control |
panel |
|
11 |
|
|
||||||||||||||||||||||||||||||||||
LED indicators |
11 |
|
|
||||||||||||||||||||||||||||||||||||
Buttons |
|
|
|
|
|
|
|
|
|
|
12 |
|
|
||||||||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|||||||||||||||||||
Remote control |
|
12 |
|
|
|||||||||||||||||||||||||||||||||||
Setting up the remote control |
12 |
|
|
||||||||||||||||||||||||||||||||||||
Notes |
|
12 |
|
|
|||||||||||||||||||||||||||||||||||
Caution |
13 |
|
|
||||||||||||||||||||||||||||||||||||
Remote |
control functions |
13 |
|
||||||||||||||||||||||||||||||||||||
Regulating airflow direction |
|
|
|
|
15 |
|
|
||||||||||||||||||||||||||||||||
Manual drainage |
|
|
|
|
16 |
|
|||||||||||||||||||||||||||||||||
Drain parts |
|
|
|
|
|
|
|
|
|
|
|
16 |
|
|
|||||||||||||||||||||||||
Draining with the drain tray |
16 |
|
|||||||||||||||||||||||||||||||||||||
Direct drainage |
|
|
17 |
|
|
||||||||||||||||||||||||||||||||||
Maintenance |
|
|
|
|
|
|
17 |
|
|||||||||||||||||||||||||||||||
Notes |
|
|
|
|
|
|
|
|
|
|
17 |
|
|
||||||||||||||||||||||||||
Cleaning the Exterior |
17 |
|
|
||||||||||||||||||||||||||||||||||||
Cleaning the condenser |
|
coils |
17 |
|
|
||||||||||||||||||||||||||||||||||
Prefilter and charcoal filter |
|
17 |
|
||||||||||||||||||||||||||||||||||||
Notes |
|
|
|
17 |
|
|
|||||||||||||||||||||||||||||||||
Installing the charcoal filter |
18 |
|
|||||||||||||||||||||||||||||||||||||
Cleaning the prefilter |
|
18 |
|
||||||||||||||||||||||||||||||||||||
Long term storage |
|
18 |
|
|
|||||||||||||||||||||||||||||||||||
Troubleshooting |
|
19 |
|
|
|||||||||||||||||||||||||||||||||||
Limited warranty |
|
|
22 |
|
|
1
Thank you
Thank you for purchasing an EdgeStar portable air conditioner. Rest assured that all EdgeStar products are designed and manufactured to the highest standards. We would like you to be able to fully utilize all features of this portable air conditioner, so please take the time to read this owner’s manual in full prior to using the unit.
Energy saving tips:
1.Use the portable air conditioner for the recommended room size. Rooms that are too small can cause the unit to short cycle and work inefficiently. Rooms that are too large will never cool completely.
2.Be careful not to obstruct the air flow coming out of the portable air conditioner. A powerful, unobstructed airflow is crucial for optimum cooling.
3.Keep blinds and curtains closed during the sunniest part of the day.
4.Clean the pre-filter often, and replace the activated carbon filter as needed (it should be replaced twice a year under normal conditions).
5.Close your fireplace damper, floor grills, and wall grills to prevent cool air from escaping.
6.Avoid opening doors frequently
7.Note that each additional person in room adds between 100-150 BTU of heat, so the more people in a room, the more cooling capacity is required
8.Set the portable air conditioner to maximum cooling and high speed airflow when you first start it up, and then adjust the unit to a comfortable setting.
Notes:
The portable air conditioner must be plugged into an appropriate power outlet. Refer to the rating label on the back of the unit for more information.
The portable air conditioner is a compressor-driven cooling system. The air conditioner has an anti-overheating safety feature that can delay the compressor from starting for three minutes after the air conditioner turns on or when a mode change is made. If the compressor does not immediately start, it is likely because of this feature. To protect the compressor from overheating or freezing, it will only operate when the ambient temperature is between 61° and 97°F.
Always unwind the power cord completely before use.
Please note that in Cooling, Heating, Auto, and Dry modes, the exhaust hose must be used.
The heating function is equipped with an auto-defrost function. When using the heating function, heating may be interrupted briefly to melt any accumulated frost. Heating will begin again once the frost is melted.
When switching into the Cooling mode or Heating mode, cooling or heating may be temporarily delayed as the unit cools down / heats up.
2
Specifications
Model |
AP410HS |
Maximum Room Size (cooling)* |
400 ft² |
Maximum Room Size (heating)* |
400 ft² |
Power consumption for cooling mode |
1150W |
Power consumption for heating mode |
1050W |
Air flow |
212 ft³/m |
Humidity removal capacity |
2.11 p/h |
Noise level |
<54 dbA |
Power supply |
120V/ 60Hz |
Compressor |
Rotary |
Refrigerant |
R-22 or R-470C |
Refrigerant Load |
450g |
Timer |
1-12 hours |
Thermostat |
61°-88°F |
Net weight |
71 pounds |
Dimensions |
29 1/4"h x 15"w x 14 3/4"d |
Box dimensions |
29 15/16"h x 21"w x 17 3/8"d |
*Please note that maximum room sizes are under ideal conditions. Actual cooling/heating areas may vary
Safety precautions:
1.Transport the portable air conditioner in an upright position only. If the unit is tipped over, make sure it stands upright for at least 3 hours prior to turning it on.
2.Always place the unit on a level surface.
3.In order to cool, the hot air from the exhaust port in the rear of the portable air conditioner must be exhausted outside the room.
4.Make sure the portable air conditioner is connected to a grounded power outlet.
5.This portable air conditioner is designed to operate in an ambient temperature of 61°-97° F.
3
6.This portable air conditioner has been designed for residential use.
7.Always turn the portable air conditioner off before unplugging it.
8.Do not damage the power cord.
9.Do not use this portable air conditioner for functions other than those described in this owner’s manual.
10.Do not tilt the portable air conditioner.
11.Do not cover or obstruct the intake or outlet grills.
12.Do not use the portable air conditioner in a wet roomsuch as a bathroom or laundry roomto avoid the possibility of shock.
13.Do not bend or crush the exhaust hose while in use.
14.Do not sit on, or place articles on, the portable air conditioner.
15.Do not touch the portable air conditioner with wet or damp hands
16.Do not let chemical substances come into contact with the portable air conditioner.
17.Do not use the portable air conditioner in the presence of flammable substances or vapors such as alcohol, insecticides, gas, etc.
18.Do not use the plug to start or stop the unit.
19.Do not yank on the electric cord or place it near a source of heat. If the electric cord is damaged, it must be replaced by an authorized service agent.
20.Always use the control panel to start or stop the portable air conditioner.
21.Always allow for air flow around the portable air conditioner of at least 20”.
22.Always turn off the portable air conditioner when not in use.
23.Always turn the portable air conditioner off and unplug it after use, before cleaning, before carrying out maintenance, and before moving it.
24.It the electrical socket is different from the plug, have a professionally qualified electrician replace the socket with a suitable one. Do not use adapter plugs, multiple sockets, or extension cords.
25.The filter must be used at all times. When removing the filter for cleaning, turn off the unit and unplug it.
26.Make sure all children are properly supervised around this portable air conditioner.
4
Parts
Front view
1.Control panel
2.Adjustable louvers
3.Carry handles
4.Caster wheels
Rear view
1.Air inlet
2.Exhaust port
3.Power cord hooks
4.Caster wheels
5.Drain plug (a plastic drain cap covers a rubber stopper)
5
Accessories
|
|
|
Owner’s manual and |
|
Drain hose |
||
|
|
warranty card |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Exhaust hose |
|
|
|
|
|
|
|
Rectangular vent |
|
connector |
Round adapter |
|
Drain tray
Carbon filter
Cap for round adapter
|
|
Plastic window kit |
Remote and batteries |
|
and screws |
|
|
|
|
|
|
6
Installation
Installing the exhaust hose
In order to be used effectively, the exhaust hose must be mounted to the back of the unit.
1.Make sure the rectangular vent connector is fitted to one end of the exhaust hose and fit the round adapter to the other end.
2.Insert the rectangular vent connector into the exhaust port on the back of the unit.
7