![](/html/53/532e/532e1d870ba363856e0229a8d5eb260099413cb6e18971619d09d9f3f681997a/bg1.png)
904-PSB-30-12VDC-04
© 2015 Edge Lighting. All Rights Reserved.
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
info@edgelighting.com
PSB-30-12VDC
Installation Instructions for 30 Watt 12 Volt DC LED Power Supply
SAVE THESE INSTRUCTIONS!
GENERAL INFORMATION IMPORTANT SAFETY INSTRUCTIONS
- RISK OF FIRE: This product must be installed by a
qualified electrician. Turn the power to the electrical box off
during installation. Read the "Important Safety Instructions "
before installation.
- NOTE: To avoid overheating the power supply, install it in a
ventilated remote location where air flows. Maintain proper
spacing among power supplies when multiple power
supplies are installed in the same remote location.
- This product is not suitable for wet locations. It is approved
for the use at any height above the finished floor.
- A typical installation is shown. Specific installation must be
in accordance with the local electrical codes.
- TO REDUCE RISK OF FIRE, it is important to wire the
power supply for the system as described in this
installation instruction.
- Load the power supply to MAXIMUM 30 Watts.
- Use Lightolier "ZP600FAM120" 0-10 volt controller to dim
the Warm White LED soft strip.
- Use CDP color dial or CTP color touch screen controller with
RGB LED soft strip.
- Do not install this power supply in a wet location.
- To reduce the risk of the system overheating and possibly
causing a fire, make sure all the connections are tight.
- Do not install *LED fixture closer than three inches or as
specified in the *LED fixture installation instructions to
curtains or similarly combustible materials. Keep insulation
at least 3" away from the enclosure.
- Turn the electrical power off before modifying the lighting
system in any way.
- The system is "ETL" listed for USA and Canada only when
all the products used are supplied by Edge Lighting.
* See LED fixture installation instructions for proper
placement.
POWER SUPPLY
WATTAGE
30 WATT
12 Volt
LOW VOLTAGE WIRE SIZE CHART
WIRE SIZE
UP TO 26 FT
#14 GA #12 GA #10 GA #8 GA
WIRE SIZE
FOR 27-41 FT
WIRE SIZE
FOR 42-68 FT
WIRE SIZE
FOR 69-100 FT
1
![](/html/53/532e/532e1d870ba363856e0229a8d5eb260099413cb6e18971619d09d9f3f681997a/bg2.png)
Using LED Power Supply with a Light Switch & Warm White
Soft Strip (Non-Dimmable)
A
PHILLIPS SCREW
"N" White
"L" Black
T
" " GREEN
POWER SUPPLY
White +
Black -
1
COVER
CASE
2: Install conduits from the light switch, main panel (line
voltage) and soft strip to the power supply case.
3: Run proper size wires from the light switch electrical box to
the power supply case.
4: Run the line voltage power wires from the panel to the
power supply case.
NOTE: Skip this section if dimming the warm white LED soft
strip or using RGB soft strip.
1: Loosen the six Phillips screws on front of the power supply to
remove the cover.
B
CONDUIT
2
ELECTRICAL BOX
3
"N" White
"L" Black
T
" " GREEN
4
POWER LINE WIRES
LIGHT SWITCH
White +
Black -
C
5: Connect the hot power wire to one of the wires coming
from the switch with a wire nut.
6: Connect the other switch wire to the black power supply
wire marked "L" with a wire nut.
7: Connect the neutral power wire to white power supply wire
marked "N" with a wire nut.
8: Make sure the green transformer wire is grounded in
6
5
7
"N" White
"L" Black
" " GREEN
White +
Black -
8
accordance with local electrical codes.
2
![](/html/53/532e/532e1d870ba363856e0229a8d5eb260099413cb6e18971619d09d9f3f681997a/bg3.png)
D
12
11
9: Use the "Low Voltage Wire Size Chart" on page 1 to
determine the proper wire size connecting the power supply
to the LED soft strip.
10: Run the proper size, red and black wires from the power
supply case to the LED soft strip.
"N" White
"L" Black
" " GREEN
LED SOFT STRIP
White +
Black -
14
13
NOTE: Maximum length of a single soft strip to be
connected to power supply before re-feeding is 16' of SS1 or
8' of SS3.
NOTE: Use only 12 volt LED soft strip with this power
supply.
11: Connect the white power supply wire marked "+" to red
conduit wire going to the soft strip.
12: Connect the black power supply wire marked "-" to black
conduit wire going to soft strip.
13: Connect the red conduit wire to red soft strip wire(s) with a
wire nut.
14: Connect the black conduit wire to black soft strip wire(s)
with a wire nut.
E
COVER
16
PHILLIPS SCREW
15
Dimming
L N G
0-10V
LED + LED -
15: Replace the power supply cover and secure it by tightening
the six Phillips screws.
Using LED Power Supply with Warm White Soft Strip & 0-10
Volt Dimmer
F
1
COVER
PHILLIP
SCREW
COVER
"N" White
"L" Black
T
" " GREEN
PHILLIPS SCREW
2
10-24 V=
+
SELV
IN
-
<0.6 mA
DIM MODULE
1-10V=
+
-
OUTPUTS TO LED MODULES
White +
Black -
CASE
WIRE
TERMINAL
BLOCK
2
NOTE: Skip this section if using the LED power supply with
a RGB soft strip.
1: Loosen the six Phillips screws on front of the power supply to
remove the cover.
2: Loosen the two Phillips screws on the front of the dim
module (OT-DIM – sold separately) and remove the covers to
expose the terminal blocks.
3