Edge Lighting Mata Hari 3 User Manual

1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
© 2011 Edge Lighting. All Rights Reserved.
info@edgelighting.com
Installation Instructions for Mata Hari 3
IMPORTANT SAFETY INSTRUCTIONS
To reduce the risk of fire, electrical shock, exposure to excessive UV radiation, or injury to persons:
- Use this fixture indoors only.
- Do not look directly at the lamp while the fixture is on.
- RISK OF FIRE: Use only the type of lamp and maximum wattage indicated in this instruction manual.
- Never cover the halogen lamp with anything other than a lamp shield provided by Edge Lighting and never place flammable material close to the fixture.
- Never turn the fixture on and off by connecting and disconnecting the halogen lamp.
- Do not touch the fixture head, shade or lamp shield while the fixture is on. These surfaces may be VERY HOT.
- Do not touch lamp at anytime. Use a soft cloth instead as oil from skin may damage lamp.
- It is normal for a new halogen lamp to produce minor smoke when first turned on.
- Do not operate the luminaire with a missing or damaged shield.
- Turn power off and allow to cool before replacing lamp.
FJ-MATA3-_
904-FJ-MATA3-01
IMPORTANT INFORMATION
- This product is ETL listed for indoor dry locations and approved to be used at any height above the finished floor.
SAVE THESE INSTRUCTIONS!
Adjust the Fixture Height
A
H
1: Cut the coaxial cable to the desired height (H) with a sharp cutter. The overall fixture height is measured from the bottom of the glass shade to the end of the coaxial cable.
1
112
B
STRAIN RELIEF TUBE
2
2: Feed the coaxial cable through the conical nipple and flared
side of the strain relief tube. Slide the conical nipple and strain relief tube down the coaxial cable.
CONICAL NIPPLE
3: Feed the coaxial cable into the coaxial fixture connector. The coaxial cable will come to a stop point.
COAXIAL CABLE
D
1.5MM ALLEN WRENCH
M3 SET SCREW
WRINKLE
5
4
C
3
COAXIAL CABLE
4: Keep feeding the coaxial cable in until the inner wire is visible in the screw hole of the fixture connector tip. The outer metal jacket will start to wrinkle.
5: Hold the fixture connector in place. Replace and tighten the M3 set screw on fixture connector tip with the 1.5mm Allen wrench.
6: Pull down the outer metal jacket to smooth the wrinkles.
6
OUTER METAL JACK INNER WIRE
7: Push the strain relief tube completely into the coaxial fixture connector. Make sure the slot on the strain relief tube is not inline with the M4 set screw.
8: Tighten the M4 set screw with the 2mm Allen wrench.
E
2MM ALLEN WRENCH
M4 SET SCREW
COAXIAL FIXTURE CONNECTOR
8
7
STRAIN RELIEF TUBE
Loading...
+ 1 hidden pages