LCMW-24V-_
Installation Instructions for Millwork Light Channel, 24VDC
IMPORTANT INFORMATION
- This instruction shows a typical installation.
SAVE THESE INSTRUCTIONS!
Install the Light Channel
904-LCMW-24V-01
A
1 3/8"
FOR
CORD
5/8" CUT
DEPTH
7/8" CUT
NOTE:
connected together with the flexible connectors. Refer to the instructions provided with the flexible connectors.
Multiple light channels up to total of 25 feet long can be
CHANNEL
LENGTH
WOOD
MITER CUT
7/8" WIDE
1: Determine the location of the Millwork Light Channel on the wood.
NOTE:
3/4" thick wood. The cut out slot must be 7/8" wide and 5/8" deep. Add 1-3/8" to the length of the channel to accommodate the power cord spacing.
The Millwork Light Channel needs to be installed onto a
B
LIGHT CHANNEL
FLEXIBLE CONNECTOR
ADDITIONAL LIGHT CHANNEL
C
SCREW
FLEXIBLE CONNECTOR
POWER FEED CONNECTOR
2
DECORATIVE CAP
3
LIGHT CHANNEL
END CAP
POWER FEED CONNECTOR
POWER FEED WIRES
SCREW
NOTE:
female or male end of the channel.
The power feed cable can be mounted to either the
2: Remove the two screws on the bottom of the light channel (not the screws holding the decorative cap).
3: Place the male end of the power cord in the cord grip if
LIGHT CHANNEL
connecting to the female end of the light channel, or place the female end of the power cord in the cord grip if connecting to the male end of the light channel.
4: Push the cord completely into the light channel power end
4
cap pins and secure the cord grip to the light channel by tightening the two screws (provided with cord grip) through the cord grip into the light channel power end cap.
1
D
LIGHT CHANNEL
POWER CORD
5: Cut the other end of the power cord (male or female) and discard it. Strip the wire end for connecting it to the power supply.
5
E
7
CUT
5
MOUNTING PLATE
SLOT
6: Drill one end of the slot with 7/32 bit to run the light channel wire.
7: Feed the wires through the hole and snap the light channel into the slot, make sure all clips are tight. If necessary slide the mounting clip to the appropriate area.
8: Follow the instructions provided with the power supply to power up the light channel.
Replacing the Soft Strip
F
1
REMOVE OLD SOFT STRIP
2
BACKING
SOFT STRIP
CHANNEL
LIGHT CHANNEL
7
1: Carefully pull existing old Soft Strip completely off the
channel.
2: If there is Soft Strip residue on the channel apply in moderation WD-40, or Goo Gone, or a mixture of warm water and lemon oil to the corner of a clean, dry towel. Gently buff the area containing the adhesive residue with small circular motion until it is completely removed.
NOTE: Avoid bending the soft strip in sharp vertical angles which may damage the LEDs. Soft Strips do not bend horizontal. Use proper directional connectors for horizontal turns.
3: Carefully remove the backing from the new LED soft strip, make sure not to remove the tape from the soft strip. Firmly press down the adhesive portion of the soft strip onto the channel while removing the rest of the backing, making sure there are no air bubbles that can cause surface irregularities.
GENERAL WIRING DIAGRAM
WHITE (NEUTRAL)
INPUT
120VAC
GND
BLACK (HOT)
RED 120VAC (HOT)
PURPLE 1-10V
GRAY 1-10V
DIMMING
LIGHTOLIER:
ZP600FAM120
CONTROLLER
PSB-96W-010-24VDC
input 120VAC WH (N) BK (L)
input 0-10V PUR GRY
RED (24VDC+)
BLUE (RETURN-)
YELLOW (DIM RETURN-)
24VDC
RED 24VDC+
BLACK 24VDC-