© 2013 Edge Lighting. All Rights Reserved.
1718 W. Fullerton Ave
Chicago, IL 60614
Tel: 773-770-1195
Fax: 773-935-5613
www.edgelighting.com
info@edgelighting.com
LCMW-24V-_
Installation Instructions for Millwork Light Channel, 24VDC
IMPORTANT INFORMATION
- This instruction shows a typical installation.
SAVE THESE INSTRUCTIONS!
Install the Light Channel
904-LCMW-24V-01
A
1 3/8"
FOR
CORD
5/8"
CUT
DEPTH
7/8" CUT
NOTE:
connected together with the flexible connectors. Refer to the
instructions provided with the flexible connectors.
Multiple light channels up to total of 25 feet long can be
CHANNEL
LENGTH
WOOD
MITER CUT
7/8" WIDE
1: Determine the location of the Millwork Light Channel on the
wood.
NOTE:
3/4" thick wood. The cut out slot must be 7/8" wide and 5/8"
deep. Add 1-3/8" to the length of the channel to accommodate
the power cord spacing.
The Millwork Light Channel needs to be installed onto a
B
LIGHT CHANNEL
FLEXIBLE
CONNECTOR
ADDITIONAL
LIGHT CHANNEL
C
SCREW
FLEXIBLE
CONNECTOR
POWER FEED
CONNECTOR
2
DECORATIVE
CAP
3
LIGHT CHANNEL
END CAP
POWER FEED
CONNECTOR
POWER FEED
WIRES
SCREW
NOTE:
female or male end of the channel.
The power feed cable can be mounted to either the
2: Remove the two screws on the bottom of the light channel
(not the screws holding the decorative cap).
3: Place the male end of the power cord in the cord grip if
LIGHT
CHANNEL
connecting to the female end of the light channel, or place
the female end of the power cord in the cord grip if
connecting to the male end of the light channel.
4: Push the cord completely into the light channel power end
4
cap pins and secure the cord grip to the light channel by
tightening the two screws (provided with cord grip) through
the cord grip into the light channel power end cap.
1

D
LIGHT CHANNEL
POWER CORD
5: Cut the other end of the power cord (male or female) and
discard it. Strip the wire end for connecting it to the power
supply.
5
E
7
CUT
5
MOUNTING PLATE
SLOT
6: Drill one end of the slot with 7/32 bit to run the light channel
wire.
7: Feed the wires through the hole and snap the light channel
into the slot, make sure all clips are tight. If necessary slide
the mounting clip to the appropriate area.
8: Follow the instructions provided with the power supply to
power up the light channel.
Replacing the Soft Strip
F
1
REMOVE OLD
SOFT STRIP
2
BACKING
SOFT STRIP
CHANNEL
LIGHT CHANNEL
7
1: Carefully pull existing old Soft Strip completely off the
channel.
2: If there is Soft Strip residue on the channel apply in
moderation WD-40, or Goo Gone, or a mixture of warm
water and lemon oil to the corner of a clean, dry towel.
Gently buff the area containing the adhesive residue with
small circular motion until it is completely removed.
NOTE: Avoid bending the soft strip in sharp vertical angles which
may damage the LEDs. Soft Strips do not bend horizontal. Use
proper directional connectors for horizontal turns.
3: Carefully remove the backing from the new LED soft strip,
make sure not to remove the tape from the soft strip. Firmly
press down the adhesive portion of the soft strip onto the
channel while removing the rest of the backing, making sure
there are no air bubbles that can cause surface irregularities.
GENERAL WIRING DIAGRAM
WHITE (NEUTRAL)
INPUT
120VAC
GND
BLACK (HOT)
RED 120VAC (HOT)
PURPLE 1-10V
GRAY 1-10V
DIMMING
LIGHTOLIER:
ZP600FAM120
CONTROLLER
PSB-96W-010-24VDC
input 120VAC
WH (N)
BK (L)
input 0-10V
PUR
GRY
RED (24VDC+)
BLUE (RETURN-)
YELLOW (DIM RETURN-)
24VDC
RED 24VDC+
BLACK 24VDC-
SURFACE MOUNT
LIGHT CHANNEL
2